Gas concentration converter

Convert gas concentrations between ppm, % by volume, %LEL and mg/m³ for common flammable and toxic gases, at 25 °C and 1 atm. The LEL value can be edited to match the calibration basis of your detector. Built for safety, operations and maintenance engineers; it runs in your browser and sends no data anywhere.

Gas concentration converter

Molar mass M: -

% vol

Default from the GESTIS table. Edit it if your detector is calibrated on a different value.

ppm
% vol
%LEL
mg/m³

Type in any field and the others update. mg/m³ is at 25 °C, 1 atm.

How it is calculated

  • % by volume = ppm / 10,000 (1 % by volume = 10,000 ppm).
  • %LEL = % by volume / LEL × 100, with the LEL in % by volume.
  • mg/m³ = ppm × M / 24.45, with M the molar mass (g/mol) and 24.45 L/mol the molar volume of an ideal gas at 25 °C and 1 atm (101.325 kPa).
  • For an ideal gas mol % = % by volume. At 1 atm the gases in the table are treated as ideal gases.

Gases used by the tool

Gas Formula M (g/mol) LEL (% vol) 1 %LEL = ppm 1 ppm = mg/m³
Methane CH₄ 16.04 4.4 440 0.656
Ethane C₂H₆ 30.07 2.4 240 1.23
Propane C₃H₈ 44.10 1.7 170 1.804
n-Butane C₄H₁₀ 58.12 1.4 140 2.377
n-Pentane C₅H₁₂ 72.15 1.1 110 2.951
n-Hexane C₆H₁₄ 86.18 1 100 3.525
Hydrogen H₂ 2.02 4 400 0.083
Ethylene C₂H₄ 28.05 2.4 240 1.147
Acetylene C₂H₂ 26.04 2.3 230 1.065
Ammonia NH₃ 17.03 14 1400 0.697
Methanol CH₃OH 32.04 6 600 1.31
Ethanol C₂H₅OH 46.07 3.1 310 1.884
Isopropanol (2-propanol) C₃H₈O 60.10 2 200 2.458
Acetone C₃H₆O 58.08 2.5 250 2.375
Toluene C₇H₈ 92.14 1 100 3.769
Hydrogen sulfide H₂S 34.08 – – 1.394
Carbon monoxide CO 28.01 – – 1.146

Toxic gases (H₂S, CO) have no LEL column because the %LEL scale is not used for them.

Sources

  • Molar mass and LEL: GESTIS Substance Database, IFA (Institut für Arbeitsschutz der DGUV); explosion data from the CHEMSAFE database (DECHEMA, PTB, BAM), entries read 2026-11-07. gestis.dguv.de/
  • Example of another LEL basis (methane 5.0 %): Industrial Scientific, LEL Correlation Factors chart. industrialscientific.com/hubfs/lel-gas-chart.pdf
  • ppm / mg/m³ factor at 25 °C, 1 atm: NIOSH Pocket Guide to Chemical Hazards, "1 ppm = x mg/m³" at 25 °C and 1 atm (the same 24.45 L/mol). cdc.gov/niosh/npg/

The LEL standard for hazardous areas is IEC 60079-20-1 (material characteristics for gas and vapour classification). This tool does not replace it: when you design to the standard, use the values given in it and edit the "LEL" field.

Worked example

Methane, 50 %LEL, LEL = 4.4 % by volume (M = 16.04 g/mol). % by volume = 50 / 100 × 4.4 = 2.2 %; ppm = 2.2 × 10,000 = 22,000 ppm; mg/m³ = 22,000 × 16.04 / 24.45 = 14,433 mg/m³. If the detector is calibrated on an LEL of 5.0 %, the same 50 %LEL is 2.5 % by volume.

Hydrogen sulfide, 10 ppm (M = 34.08 g/mol). % by volume = 10 / 10,000 = 0.001 %; mg/m³ = 10 × 34.08 / 24.45 = 13.9 mg/m³.

Frequently asked questions

What is %LEL and what does 100 %LEL mean?
LEL (Lower Explosive Limit) is the lowest concentration of a flammable gas in air that can ignite, in % by volume. %LEL = concentration (% by volume) / LEL × 100. At 100 %LEL the concentration equals the lower explosive limit. Methane has an LEL of 4.4 % by volume, so 50 %LEL is 2.2 % by volume, i.e. 22,000 ppm.
Why can the same gas have different LEL values (for example methane 4.4 % and 5.0 %)?
The LEL value depends on the data table and the test conditions. The GESTIS table used here gives methane 4.4 % by volume; some instrument makers calibrate on 5.0 % (for example the Industrial Scientific chart). A detector shows %LEL on whatever basis it was calibrated on, so check the instrument manual and enter that value in the "LEL" field: 50 %LEL is 2.2 % by volume with an LEL of 4.4 % but 2.5 % by volume with an LEL of 5.0 %.
At what conditions is ppm converted to mg/m³?
The tool uses 25 °C and 1 atm (101.325 kPa), where the molar volume of an ideal gas is 24.45 L/mol: mg/m³ = ppm × M / 24.45, with M the molar mass (g/mol). At other conditions (for example 0 °C or 20 °C) the factor differs, so a comparison with an occupational exposure limit must use the same reference conditions.
Why do CO and H₂S have no %LEL here?
CO and H₂S are toxic gases, monitored with toxic (electrochemical) sensors in ppm, because the level harmful to people is far below the explosive range. The tool therefore converts only ppm, % by volume and mg/m³ for these two gases. Need a detector for the right gas and range? Send a request to a CAD engineer.

Next steps

Quote