Honeywell HON 200 Gas Pressure Regulator
100% GENUINE
View larger
Honeywell HON 200 Gas Pressure Regulator

Honeywell HON 200 Gas Pressure Regulator

PRODUCT CODE
CAD-FL-141
BRAND
Honeywell

Honeywell HON 200 is a pilot-operated gas pressure regulator to DIN EN 334 (PED registered) with a fail-close function. Inlet pressure up to 100 bar, outlet up to 90 bar, pipe connections 18 to 42 mm or DIN PN 40 / ANSI Class 300, 600 flanges. For gas regulating stations and industrial plants.

  • Max. admissible pressure PS 100 bar (depending on type of flange)
  • Max. inlet pressure pu max up to 100 bar
  • Outlet pressure range Wd 0.02 bar up to 90 bar
  • Min. pressure drop approx. 1 bar, others on enquiry
REQUEST A QUOTE
  • Genuine products
  • Full CO/CQ
  • VAT invoice
  • Quote within 24 working hours

PRODUCT DESCRIPTION

Honeywell HON 200 Gas Pressure Regulator

HON 200 is a pilot-operated gas pressure regulator according to DIN EN 334, with CE registration according to PED.

Applications include:

  • Device for offtake stations in gas transmission, industrial facilities and low-load lines in larger gas pressure regulating stations
  • Optional outdoor type
  • Suitable for large turn down ratios
  • Installation of different valve seat diameters is possible
  • Straightforward, easy-to-maintain design
  • Suitable for controlling outlet and inlet pressure, outlet and differential pressure (flow control), and superimposed electric control loops
  • Fail-close function
  • Suitable for non-aggressive gases and other gases on enquiry.

Other features include:

  • Max. admissible pressure PS: 100 bar (depending on type of flange)
  • Max. inlet pressure pu max: up to 100 bar
  • Outlet pressure range Wd: 0.02 bar up to 90 bar
  • Min. pressure drop approx.: 1 bar, others on enquiry
  • Class of lock-up pressure zone: SZ 2.5
  • Connection
    • Pipe connections according to DIN EN ISO 8434-1 (DIN 2353), for pipe diameters 18 mm, 22 mm, 25 mm, 28 mm, 38 mm, 42 mm
    • DIN flange PN 40 or Flange Class 300, Class 600 according to ANSI 16.5 with transition pieces in DN 25, DN 40, DN 50
  • Supplemental fixture (as requested by customer):
    • Electrical and pneumatic remote setpoint adjustment

    • Fitted with noise-reducing outlet device flanges PN 40 or Class 600 according to ANSI 16.5

    • Pipe connection for use with SSVs HON 703 and/or 704.

All mechanical components of this device are without potential ignition sources and/ or hot faces. They are not subject to ATEX 95 (94/9/EC). All electronic accessories, on the other hand, meet ATEX requirements.

Design and operating principle

The HON 200 consists of the main valve assembly (valve and diaphragm actuator) and a two-stage pilot assembly (load-limiting stage and pilot control stage), with a fine mesh filter upstream of the pilot. The manufacturer uses the pressure difference between inlet and outlet as auxiliary energy; the pilot compares the measured outlet pressure with the setpoint (spring force) and adjusts the loading pressure on the main valve to hold the outlet pressure steady. The regulator closes tight at zero consumption. The usual pilots are the HON 610 (RS 10 d) and HON 650; electrical or pneumatic remote setpoint adjustment can be added.

Seat sizes and inlet pressure limits

Valve seat diameter (mm) 5 6 8 12 18 23
Max. inlet pressure (bar) 100 100 100 80 40 25
Flow coefficient KG (m³/h, natural gas) 12 25 50 125 200 250

Accuracy class AC from 1 to 10 and closing pressure group SG depend on the outlet pressure range and seat diameter; lock-up pressure zone class SZ 2.5; minimum pressure difference about 1 to 1.5 bar. Temperature range class 2: -20 to +60 °C. Main valve body in aluminium alloy or steel; diaphragms and O-rings in Perbunan; pipe size DN 25.

Standards and options

  • Function and strength to DIN EN 334; CE registration under PED; DIN DVGW registration NG-4301AR0881.
  • The mechanical parts have no potential ignition sources and are not subject to ATEX 95; electronic accessories meet ATEX requirements.
  • Options on request: electrical or pneumatic remote setpoint adjustment, noise-reducing outlet device (PN 40 or Class 600 flanges), connection for the HON 703 / HON 704 safety shut-off valves, outdoor version, oxygen version.

What to send for a quote

  • Gas type (natural gas or other) and maximum and minimum flow.
  • Minimum and maximum inlet pressure and the outlet pressure to set.
  • Connection type: DIN 2353 pipe fitting or flange (DIN PN 40, ANSI Class 300/600; DN 25, 40, 50).
  • Whether you need an HON 703/704 safety shut-off valve, remote setpoint, noise reduction or an outdoor version.

CAD replies with a quote within 24 working hours of receiving the details.

TECHNICAL SPECIFICATIONS

Specifications of Honeywell HON 200 Gas Pressure Regulator

PARAMETER VALUE
Model HON 200
Max. admissible pressure PS 100 bar (depending on type of flange)
Max. inlet pressure pu max up to 100 bar
Outlet pressure range Wd 0.02 bar up to 90 bar
Min. pressure drop approx. 1 bar, others on enquiry
Class of lock-up pressure zone SZ 2.5
Brand Honeywell
Standards DIN EN 334, CE per PED
Flange connections DIN PN 40 or ANSI 16.5 Class 300, 600 (DN 25, 40, 50)
Pipe connections DIN EN ISO 8434-1 (DIN 2353), 18 to 42 mm
Function Fail-close

Specifications may vary with the ordered configuration. Contact a CAD engineer for sizing to your actual operating conditions.

FAQ

Frequently asked questions about CAD-FL-141

What kind of regulator is the HON 200?

A pilot-operated gas pressure regulator to DIN EN 334, CE registered under PED, with a fail-close function. The usual pilots are the HON 610 or HON 650.

What are the maximum inlet and outlet pressures of the HON 200?

Permissible inlet pressure is up to 100 bar, limited by seat diameter: 100 bar for 5 to 8 mm seats, 80 bar for 12 mm, 40 bar for 18 mm, 25 bar for 23 mm. The outlet pressure can be set up to 90 bar depending on spring and pilot.

Which gases can the HON 200 handle?

The standard version is for natural gas and other non-aggressive gases; oxygen, outdoor and other special versions are made on request.

Does the HON 200 need ATEX certification?

According to the manufacturer, the mechanical parts have no potential ignition sources and are not subject to ATEX 95; the electronic accessories meet ATEX requirements.

What do I need to send for an HON 200 quote?

Gas type, flow, min/max inlet pressure, outlet setpoint, connection type and options (HON 703/704, remote setpoint, noise reduction). CAD replies within 24 working hours.

Used this product? Write a review

Your rating

20 to 1500 characters, no links.

CAD uses your name, company and text only to publish your review once approved. Your email is for CAD to check only; it is never shown or used for anything else.