TECOFI CDB6461-VI Stainless Steel Dual Plate Check Valve
Tecofi CDB6461-VI wafer double plate check valve: 316 stainless steel body and plates, FPM seat, fits between PN10–PN40 / Class 150–300 flanges, DN40–DN300, 40 bar, -25 to +180 °C. For pumping, water supply, chemical and desalination.
- Brand Tecofi
- Origin France
- Body and bonnet Stainless steel 316
- Connection PN10/16/25/40/ASA150/300
- Genuine products
- Full CO/CQ
- VAT invoice
- Quote within 24 working hours
PRODUCT DESCRIPTION
TECOFI CDB6461-VI Stainless Steel Dual Plate Check Valve
A Tecofi (France) product. Product code: CDB6461-VI. Technical data, dimension tables and order codes (Ref.) for each size are listed below; contact CAD for sizing advice and a quote.
Body and bonnet: Stainless steel 316
Seat seal: FPM (Viton® type)
Plate: Stainless steel 316
Bolts and nuts: Stainless steel 316
Connection: PN10/16/25/40/ASA150/300
Working temperature: -25°C / +180°C
Working pressure: 40 bar
| DN (mm) | DN (inch) | L (mm) | Kg | Ref. |
|---|---|---|---|---|
| 50 | 2″ | 43 | 1.1 | CDB6461-VI0050 |
| 65 | 2″ 1/2 | 46 | 1.5 | CDB6461-VI0065 |
| 80 | 3″ | 64 | 2.4 | CDB6461-VI0080 |
| 100 | 4″ | 64 | 3.4 | CDB6461-VI0100 |
| 125 | 5″ | 70 | 5.3 | CDB6461-VI0125 |
| 150 | 6″ | 76 | 7.2 | CDB6461-VI0150 |
| 200 | 8″ | 89 | 11.9 | CDB6461-VI0200 |
| 250 | 10″ | 114 | 20.4 | CDB6461-VI0250 |
| 300 | 12″ | 114 | 28.4 | CDB6461-VI0300 |
Applications
According to Tecofi, the CDB6461 is for pumping, water supply, the chemical industry and desalination plants. Fluids: clear and slightly charged water, gas and sea water.
Features and installation
- Wafer-type double plate check valve fitted between flanges; range DN40 to DN300; designed to API 594.
- Symmetrical flow with full opening; robust, lightweight construction with a small face-to-face length that needs no maintenance. A stainless steel spring assists closing and prevents the propagation of water hammer.
- Mount on horizontal piping or on vertical piping with ascending flow; the mounting direction is shown by the arrow on the body. For horizontal mounting the axis of the valve must be vertical.
- Keep 3 to 5 times the nominal diameter of straight pipe upstream and downstream of an elbow or appliance to stay out of turbulent zones; at a pump discharge, mount according to FD CEN/TR 13932.
- Mounting between flanges PN10, PN16, PN25 and PN40 (EN 1092-1) and Class 150 (PN20) and Class 300 (PN50) (ASME B16.5).
Standards
- Face-to-face dimension according to EN 558-1 (DIN 3202-K3).
- Design according to API 594.
Minimum opening pressure
| Installation | DN40–DN65 (mbar) | DN80–DN125 (mbar) | DN150–DN300 (mbar) |
|---|---|---|---|
| Horizontal | 40 | 50 | 30 |
| Downward vertical | 35 | 45 | 20 |
| Upward vertical | 40 | 55 | 40 |
Flow factor Kv
| DN (mm) | 50 | 65 | 80 | 100 | 125 | 150 | 200 | 250 | 300 |
|---|---|---|---|---|---|---|---|---|---|
| Kv (m³/h) | 68 | 111 | 206 | 266 | 455 | 813 | 1132 | 1950 | 2300 |
Information to send with a quote request
So that CAD can quote within 24 working hours, please send:
- Valve size (DN) and quantity.
- Flange standard of the pipework (PN10/16/25/40 to EN 1092-1 or Class 150/300 to ASME B16.5).
- Fluid, working pressure and temperature.
- Installation position (horizontal, vertical ascending) and the project.
TECHNICAL SPECIFICATIONS
Specifications of TECOFI CDB6461-VI Stainless Steel Dual Plate Check Valve
| PARAMETER | VALUE |
|---|---|
| Model | CDB6461-VI |
| Brand | Tecofi |
| Origin | France |
| Body and bonnet | Stainless steel 316 |
| Connection | PN10/16/25/40/ASA150/300 |
| Working pressure | 40 bar |
| Working temperature | -25°C / +180°C |
| Seat seal | FPM (Viton® type) |
| Plate | Stainless steel 316 |
Specifications may vary with the ordered configuration. Contact a CAD engineer for sizing to your actual operating conditions.
FAQ
Frequently asked questions about CDB6461-VI
How does the CDB6461-VI differ from the CB4248A-MM and CB6140?
The CDB6461-VI is a wafer double plate valve fitted between flanges, with a stainless steel body, rated 40 bar, -25 to +180 °C. The CB4248A-MM is a flanged swing check valve in ductile iron (16 bar, 0 to +200 °C); the CB6140 is a BSP-threaded stainless steel swing check valve (16 bar, DN8–DN50).
Which flanges does the CDB6461-VI fit between?
PN10, PN16, PN25 and PN40 flanges to EN 1092-1 and Class 150 and Class 300 to ASME B16.5. Face-to-face length according to EN 558-1 (DIN 3202-K3).
How should the CDB6461-VI be installed?
On horizontal piping (valve axis vertical) or vertical piping with ascending flow, following the arrow on the body. Keep 3 to 5 DN of straight pipe upstream and downstream, and at a pump discharge mount it according to FD CEN/TR 13932.
Can the CDB6461-VI be used with sea water?
Tecofi lists clear and slightly charged water, gas and sea water as fluids, with pumping, water supply, chemical and desalination applications. Send your actual conditions so CAD can confirm the material is suitable.
What do I send to get a quote for the CDB6461-VI?
Send the DN, quantity, flange standard, fluid, pressure and temperature. CAD quotes within 24 working hours.