Tecofi TC7100 Thermometer
TC7100 is a Tecofi round-dial thermometer with a brass back sensing bulb, Ø63-100 mm dial, max. pressure 6 bar, ranges up to +200°C, for central heating and plumbing.
- Brand Tecofi
- Origin France
- Type Round-dial thermometer with back sensing bulb (heating dial thermometer)
- Dial diameter 40, 50, 63, 80, 100 mm
- Genuine products
- Full CO/CQ
- VAT invoice
- Quote within 24 working hours
PRODUCT DESCRIPTION
Tecofi TC7100 Thermometer
TC7100 is a Tecofi (France) round-dial thermometer with a brass back sensing bulb, for central heating and plumbing. This page covers TC7100 only; TB1101AL and TB1102AL are from the same maker but are glass-tube thermometers in an aluminium body (straight and angle types).
Specifications
- Type: Round-dial thermometer with back sensing bulb (heating dial thermometer)
- Dial diameter: 40, 50, 63, 80, 100 mm
- Case: Black ABS or aluminium
- Back sensing bulb: Brass; BSP thread 3/8″ (Ø40) or 1/2″ (Ø50, 63, 80, 100)
- Sensing bulb length: Standard 40 mm (Ø63, Ø80) or 40/60 mm (Ø100); 60 and 100 mm on request
- Max. pressure (PS): 6 bar
- Range: 0/+60°C; 0/+120°C; 0/+200°C; -30/+50°C; -20/+60°C
- Standard: BSP thread to ISO 228-1
| Dial diameter Ø (mm) | Sensing bulb length (mm) | Weight (kg) | Ref. (0/+120°C range) |
|---|---|---|---|
| 63 | 40 | 0.05 | TC7100AL063040-120 |
| 63 | 60 | 0.09 | TC7100AL063060-120 |
| 63 | 100 | 0.20 | TC7100AL063100-120 |
| 80 | 40 | 0.05 | TC7100AL080040-120 |
| 80 | 60 | 0.09 | TC7100AL080060-120 |
| 80 | 100 | 0.20 | TC7100AL080100-120 |
| 100 | 40 | 0.05 | TC7100AL100040-120 |
| 100 | 60 | 0.09 | TC7100AL100060-120 |
| 100 | 100 | 0.20 | TC7100AL100100-120 |
The datasheet also lists Ø40 and Ø50 dials, but this page lists Refs for Ø63, Ø80 and Ø100 only; contact CAD for other sizes or ranges other than 0/+120°C.
Difference from TB1101AL and TB1102AL
- Shape: TC7100 is a round dial (Ø40-100 mm) with a brass back sensing bulb; TB1101AL and TB1102AL are glass-tube thermometers in an aluminium body with an in-line or right-angle sensing bulb (straight / angle type).
- Working conditions: TC7100 withstands a maximum pressure of 6 bar with ranges up to +200°C; TB1101AL states 16 bar and +160°C, TB1102AL states neither.
- Case: black ABS or aluminium (datasheet); BSP thread 3/8″ for Ø40 and 1/2″ for the other sizes, whereas both TB codes have a 1/2″ thread.
Applications
General use in central heating and plumbing (datasheet: “General use: centrale heating, plumbing”).
Standards / Certifications
BSP thread to ISO 228-1. The datasheet states test procedures to EN 12266-1, DIN 3230, BS 5154 and ISO 5208. It states no other certification.
What to send for a quote
- Code TC7100 (and the full Ref code if known)
- Dial diameter (Ø63 / 80 / 100 mm) and sensing bulb length (40 / 60 / 100 mm)
- Range required
- Operating temperature, pressure (max. 6 bar) and the measured medium
- Quantity
CAD replies with a quote within 24 working hours.
Technical documentation (datasheet)
TECHNICAL SPECIFICATIONS
Specifications of Tecofi TC7100 Thermometer
| PARAMETER | VALUE |
|---|---|
| Model | TC7100 |
| Brand | Tecofi |
| Origin | France |
| Type | Round-dial thermometer with back sensing bulb (heating dial thermometer) |
| Dial diameter | 40, 50, 63, 80, 100 mm |
| Case | Black ABS or aluminium |
| Back sensing bulb | Brass; BSP thread 3/8" (Ø40) or 1/2" (Ø50, 63, 80, 100) |
| Sensing bulb length | Standard 40 mm (Ø63, Ø80) or 40/60 mm (Ø100); 60 and 100 mm on request |
| Max. pressure (PS) | 6 bar |
| Range | 0/+60°C; 0/+120°C; 0/+200°C; -30/+50°C; -20/+60°C |
| Standard | BSP thread to ISO 228-1 |
Specifications may vary with the ordered configuration. Contact a CAD engineer for sizing to your actual operating conditions.
OTHER CODES IN THE RANGE
Same series
FAQ
Frequently asked questions about TC7100
How does TC7100 differ from TB1101AL and TB1102AL?
TC7100 is a round dial with a back sensing bulb, black ABS or aluminium case, and a maximum pressure of 6 bar. TB1101AL and TB1102AL are glass-tube thermometers in an aluminium body, straight and angle types.
What dial diameters and ranges does TC7100 have?
The datasheet lists Ø40, 50, 63, 80, 100 mm dials and the ranges 0/+60°C, 0/+120°C, 0/+200°C, -30/+50°C, -20/+60°C.
How long is the TC7100 sensing bulb and what thread does it have?
Standard 40 mm for Ø63 and Ø80, 40 or 60 mm for Ø100; 60 and 100 mm on request. BSP thread 3/8" for Ø40, 1/2" for the other sizes.
What is needed for a quote on TC7100?
Send the code, dial diameter, sensing bulb length, range, operating conditions and quantity. CAD replies with a quote within 24 working hours.