Honeywell FS20X Multi-Spectrum UV / Dual IR Flame Detector
100% GENUINE
View larger
Honeywell FS20X Multi-Spectrum UV / Dual IR Flame Detector

Honeywell FS20X Multi-Spectrum UV / Dual IR Flame Detector

PRODUCT CODE
FS20X
BRAND
Honeywell

FS20X is a Honeywell multi-spectrum UV / dual IR / visible flame detector with a range up to 60 m, 3-5 second response, 4-20 mA / RS-485 outputs and FM, ATEX, IECEx approvals.

  • Brand Honeywell
  • Product type Multi-spectrum UV / dual IR / visible (UV/Dual IR/VIS) fire and flame detector
  • Field of view 90° horizontal cone of vision, ±45° from on axis
  • Sensitivity / range Very high 60 m, high 45 m, medium 30 m, low 15 m (switch selectable)
REQUEST A QUOTE DOWNLOAD DATASHEET (PDF)
  • Genuine products
  • Full CO/CQ
  • VAT invoice
  • Quote within 24 working hours

PRODUCT DESCRIPTION

Honeywell FS20X Multi-Spectrum UV / Dual IR Flame Detector

FS20X is a Honeywell multi-spectrum UV / dual IR / visible (VIS) flame detector from the FSX family of electro-optical detectors. A solar-blind UV sensor combined with WideBand IR gives a detection range up to 60 m to a 0.1 m2 n-heptane fire, with a 3-5 second response at 30 m. 4-20 mA, relay and RS-485 Modbus outputs; FM, ATEX / IECEx Ex db IIC, CU-TR and INMETRO approvals; 4X / IP66 enclosure.

How does FS20X differ from FS24X Plus and FSL100?

FS20X differs from FS24X Plus and FSL100 in sensing technology and housing. FS20X: solar-blind UV + dual IR + visible, 15-60 m range, aluminium or 316 stainless steel IP66 / 4X enclosure, -40 to +85°C operating temperature, HART as an optional module (not available on EN54-10 units). FS24X Plus: triple IR (IR3), 15-60 m range, -55 to +75°C, IP66/67, SIL 2 and EN54-10, with HART and Modbus. FSL100: UV, UV/IR or IR3 versions, GRP housing IP65, 25-35 m range, ATEX zone 2/22.

FS20X specifications

  • Brand: Honeywell
  • Product type: Multi-spectrum UV / dual IR / visible (UV/Dual IR/VIS) fire and flame detector
  • Field of view: 90° horizontal cone of vision, ±45° from on axis
  • Sensitivity / range: Very high 60 m, high 45 m, medium 30 m, low 15 m (switch selectable)
  • Response time: 3-5 seconds to a 0.1 m2 n-heptane fire at 30 m; 3-10 seconds at 60 m
  • Spectral sensitivity: Ultraviolet 185-260 nm; visible 400-700 nm; near-band IR 0.7-1.1 microns; wide-band IR 1.1-3.5 microns
  • Operating voltage: 24 VDC nominal (18-32 VDC), regulated
  • Power consumption: 85 mA operating; 135 mA alarm; additional 155 mA heater (heater turns on at -17°C)
  • Output relays: Fire alarm: SPDT (NO/NC); fault: SPST (NO); auxiliary: SPDT (NO/NC); de-energised / energised, latching / non-latching; contacts rated 1 A at 24 VDC
  • Analog output: 0-20 mA stepped, source or sink user selectable; loop resistance 50-400 Ohm
  • Communication: One of the following, user selectable: RS-485 Modbus, RS-485 FireBus II, RS-485 Special (optional); HART via optional plug-in module (not available on EN54-10 units)
  • Temperature range: Operating -40 to +85°C; storage -55 to +110°C
  • Humidity range: 5 to 98% relative humidity, non-condensing
  • Conduit entries: Standard: two M25 or two ¾” NPT
  • Enclosure materials: Copper-free powder-coated aluminium or 316 stainless steel
  • Enclosure type: 4X, IP66 and NEMA 4
  • Shipping weight: Aluminium 1.6 kg; stainless steel 3.2 kg
  • FM certification: Class I Div 1 and 2 Groups B, C, D; Class II Div 1 and 2 Groups E, F, G; Class III (the order code descriptions state Groups A, B, C, D); FM 3260
  • ATEX / IECEx certification: II 2 G Ex db IIC T4 (Ta -40 to +110°C), T5 (Ta -40 to +75°C), T6 (Ta -60 to +60°C), II 2 D Ex tb IIIC T135°C; a further version T4 (Ta -60 to +110°C), T5 (Ta -60 to +75°C), T6 (Ta -60 to +60°C)
  • Other certifications: INMETRO; CU-TR; meets SIL 2 requirements (FMEDA on request); EN54-10:2002 (option, certificate 1175a/01 LPCB, CPR 0832-CPR-F0515); EN 61000-6-4 and EN 50130-4
  • Warranty: Three years from date of shipping

Technology features

Dual microprocessors give fail-safe operation: the master performs high-speed digital sampling and signal processing, the slave handles sensor data, communications, self-diagnostics and event log storage. It stores up to 200 time-stamped events and up to 6 pre-fire FirePic records. If the UV signal is degraded by heavy smoke or a contaminated lens, the WideBand IR, near-band IR and visible sensors still alarm at reduced sensitivity and slower response. It has automatic optical-path and electronic self-test, a real-time clock, plug-in terminations for field installation and PC software with an FSIM interface for diagnostics.

Order codes

Code descriptions follow CAD’s / Honeywell’s document. FS20X-211 is the standard version, FS20X-212 the version with the FSX-A014 HART module factory installed.

Order code Description
FS20X-211-21-2 Dual IR/UV flame detector, copper-free aluminium enclosure, (2) ¾” NPT entries, FM, cFM for Class I, Division 1, Groups A, B, C, D; Class II, Division 1, Groups E, F, G; Class III
FS20X-211-22-2 Dual IR/UV flame detector, stainless steel enclosure, (2) ¾” NPT entries, FM, cFM for Class I, Division 1, Groups A, B, C, D; Class II, Division 1, Groups E, F, G; Class III
FS20X-211-23-3 Dual IR/UV flame detector, copper-free aluminium enclosure, (2) M25 entries, FM, cFM, ATEX, IECEx for Class I, Zone 1
FS20X-211-24-3 Dual IR/UV flame detector, stainless steel enclosure, (2) M25 entries, FM, cFM, ATEX, IECEx for Class I, Zone 1
FS20X-211-21-6 Dual IR/UV flame detector, copper-free aluminium enclosure, (2) ¾” NPT entries, FM, cFM for Class I, Division 1, Groups A, B, C, D; Class II, Division 1, Groups E, F, G; Class III, with EN54-10 certification
FS20X-211-22-6 Dual IR/UV flame detector, stainless steel enclosure, (2) ¾” NPT entries, FM, cFM for Class I, Division 1, Groups A, B, C, D; Class II, Division 1, Groups E, F, G; Class III, with EN54-10 certification
FS20X-211-23-6 Dual IR/UV flame detector, copper-free aluminium enclosure, (2) M25 entries, FM, cFM, ATEX, IECEx for Class I, Zone 1, with EN54-10 certification
FS20X-211-24-6 Dual IR/UV flame detector, stainless steel enclosure, (2) M25 entries, FM, cFM, ATEX, IECEx for Class I, Zone 1, with EN54-10 certification
FS20X-211-23-8 Dual IR/UV flame detector, copper-free aluminium enclosure, (2) M25 entries, CU-TR approval, T5 (operating temperature -60°C to 75°C)
FS20X-211-24-8 Dual IR/UV flame detector, stainless steel enclosure, (2) M25 entries, CU-TR approval, T5 (operating temperature -60°C to 75°C)
FS20X-212-21-2 Dual IR/UV flame detector, copper-free aluminium enclosure, (2) ¾” NPT entries, FM, cFM for Class I, Division 1, Groups A, B, C, D; Class II, Division 1, Groups E, F, G; Class III, with optional HART module FSX-A014 factory installed
FS20X-212-22-2 Dual IR/UV flame detector, stainless steel enclosure, (2) ¾” NPT entries, FM, cFM for Class I, Division 1, Groups A, B, C, D; Class II, Division 1, Groups E, F, G; Class III, with optional HART module FSX-A014 factory installed
FS20X-212-23-3 Dual IR/UV flame detector, copper-free aluminium enclosure, (2) M25 entries, FM, cFM, ATEX, IECEx for Class I, Zone 1, with optional HART module FSX-A014 factory installed
FS20X-212-24-3 Dual IR/UV flame detector, stainless steel enclosure, (2) M25 entries, FM, cFM, ATEX, IECEx for Class I, Zone 1, with optional HART module FSX-A014 factory installed
FS20X-212-23-8 Dual IR/UV flame detector, copper-free aluminium enclosure, (2) M25 entries, CU-TR approval, T5 (operating temperature -60°C to 75°C), with optional HART module FSX-A014 factory installed
FS20X-212-24-8 Dual IR/UV flame detector, stainless steel enclosure, (2) M25 entries, CU-TR approval, T5 (operating temperature -60°C to 75°C), with optional HART module FSX-A014 factory installed

Applications

The datasheet lists these applications: refineries and oil production facilities, offshore platforms, turbine / compressor enclosures, acetylene processing and storage, oil and gas pipelines and pumping stations, LNG / LPG loading and unloading facilities, natural gas and CNG plants, ethanol, methanol and IPA production and storage, crude oil and gasoline storage and tank farms, aircraft hangars, hydrogen plants and storage, paint and solvent storage, chemical production, storage and loading facilities, power plants, silane gas storage.

TECHNICAL SPECIFICATIONS

Specifications of Honeywell FS20X Multi-Spectrum UV / Dual IR Flame Detector

PARAMETER VALUE
Model FS20X
Brand Honeywell
Product type Multi-spectrum UV / dual IR / visible (UV/Dual IR/VIS) fire and flame detector
Field of view 90° horizontal cone of vision, ±45° from on axis
Sensitivity / range Very high 60 m, high 45 m, medium 30 m, low 15 m (switch selectable)
Response time 3-5 seconds to a 0.1 m2 n-heptane fire at 30 m; 3-10 seconds at 60 m
Spectral sensitivity Ultraviolet 185-260 nm; visible 400-700 nm; near-band IR 0.7-1.1 microns; wide-band IR 1.1-3.5 microns
Operating voltage 24 VDC nominal (18-32 VDC), regulated
Power consumption 85 mA operating; 135 mA alarm; additional 155 mA heater (heater turns on at -17°C)
Output relays Fire alarm: SPDT (NO/NC); fault: SPST (NO); auxiliary: SPDT (NO/NC); de-energised / energised, latching / non-latching; contacts rated 1 A at 24 VDC
Analog output 0-20 mA stepped, source or sink user selectable; loop resistance 50-400 Ohm
Communication One of the following, user selectable: RS-485 Modbus, RS-485 FireBus II, RS-485 Special (optional); HART via optional plug-in module (not available on EN54-10 units)
Temperature range Operating -40 to +85°C; storage -55 to +110°C
Humidity range 5 to 98% relative humidity, non-condensing
Conduit entries Standard: two M25 or two ¾" NPT
Enclosure materials Copper-free powder-coated aluminium or 316 stainless steel
Enclosure type 4X, IP66 and NEMA 4
Shipping weight Aluminium 1.6 kg; stainless steel 3.2 kg
FM certification Class I Div 1 and 2 Groups B, C, D; Class II Div 1 and 2 Groups E, F, G; Class III (the order code descriptions state Groups A, B, C, D); FM 3260
ATEX / IECEx certification II 2 G Ex db IIC T4 (Ta -40 to +110°C), T5 (Ta -40 to +75°C), T6 (Ta -60 to +60°C), II 2 D Ex tb IIIC T135°C; a further version T4 (Ta -60 to +110°C), T5 (Ta -60 to +75°C), T6 (Ta -60 to +60°C)
Other certifications INMETRO; CU-TR; meets SIL 2 requirements (FMEDA on request); EN54-10:2002 (option, certificate 1175a/01 LPCB, CPR 0832-CPR-F0515); EN 61000-6-4 and EN 50130-4
Warranty Three years from date of shipping

Specifications may vary with the ordered configuration. Contact a CAD engineer for sizing to your actual operating conditions.

FAQ

Frequently asked questions about FS20X

How does FS20X differ from FS24X Plus and FSL100?

FS20X is a multi-spectrum detector with a solar-blind UV sensor, dual IR and visible sensing, 15-60 m range and an IP66 / 4X enclosure. FS24X Plus uses triple IR (IR3), has an IP66/67 enclosure, SIL 2, HART and Modbus. FSL100 comes as UV, UV/IR or IR3 in an IP65 GRP housing with 25-35 m range and ATEX zone 2/22.

How far does FS20X detect and how fast does it respond?

The range is switch selectable: 15, 30, 45 or 60 m to a 0.1 m2 n-heptane fire. Response is 3-5 seconds at 30 m and 3-10 seconds at 60 m.

Which versions of FS20X are there?

Two enclosure materials (copper-free aluminium or stainless steel), two entry types (¾" NPT or M25), approval variants FM / cFM Class I Div 1, ATEX / IECEx Zone 1, EN54-10 and CU-TR (T5, -60°C to 75°C), and the 212 versions with the FSX-A014 HART module (16 codes in the table).

Used this product? Write a review