Honeywell Touchpoint Plus Touchscreen Gas Controller
100% GENUINE
View larger
Honeywell Touchpoint Plus Touchscreen Gas Controller

Honeywell Touchpoint Plus Touchscreen Gas Controller

PRODUCT CODE
Touchpoint Plus
BRAND
Honeywell

Touchpoint Plus is a Honeywell wall-mounted gas controller with 8 channels (16 with expansion), a 7-inch touchscreen, SD card logging, optional Modbus, IP65 / NEMA 4X and SIL 2.

  • Brand Honeywell
  • Product type Wall-mounted gas controller with touchscreen for small gas detection systems
  • Capacity Up to 8 channels with the base unit, up to 16 channels with an expansion unit
  • Input type 2- or 3-wire, mA or mV; 2 / 4 / 8-channel mA modules, 2 / 4 / 8-channel mV modules, or 2 mA + 2 mV, 4 mA + 4 mV; max. 15 W per channel, max. 40 W total (with dedicated A/V drive) / 68 W total (without)
REQUEST A QUOTE DOWNLOAD DATASHEET (PDF)
  • Genuine products
  • Full CO/CQ
  • VAT invoice
  • Quote within 24 working hours

PRODUCT DESCRIPTION

Honeywell Touchpoint Plus Touchscreen Gas Controller

Touchpoint Plus is Honeywell’s wall-mounted gas controller for small detector systems, supporting up to 8 channels (16 with an expansion unit). It has a 7-inch color LCD touchscreen, 3 common status LEDs and 1 LED per channel, datalogging to an SD card, an optional backup battery and optional Modbus RTU / TCP. Polycarbonate ABS enclosure rated IP65 / NEMA 4X, SIL 2 certified.

How does Touchpoint Plus differ from Unipoint and Touchpoint Pro?

Touchpoint Plus differs from Unipoint and Touchpoint Pro in scale, interface and mounting. Touchpoint Plus: a wall-mounted system with 8 channels (16 with an expansion unit), a 7-inch touchscreen, IP65 / NEMA 4X and an optional backup battery. Unipoint: a DIN-rail controller with one detector input per unit, a small LCD, mounted in an enclosure of the user’s choice. Touchpoint Pro: a modular system mounted in cabinets or racks, up to 64 input and 128 output channels, a 5.7-inch touchscreen, ring network and an optional redundant controller.

Touchpoint Plus specifications

  • Brand: Honeywell
  • Product type: Wall-mounted gas controller with touchscreen for small gas detection systems
  • Capacity: Up to 8 channels with the base unit, up to 16 channels with an expansion unit
  • Input type: 2- or 3-wire, mA or mV; 2 / 4 / 8-channel mA modules, 2 / 4 / 8-channel mV modules, or 2 mA + 2 mV, 4 mA + 4 mV; max. 15 W per channel, max. 40 W total (with dedicated A/V drive) / 68 W total (without)
  • Relay output: 12 or 24 relay outputs, NO/C/NC changeover, 1.7 A at 30 VDC / 250 VAC, user-configurable energised / de-energised, latching / non-latching, time delay
  • 4-20 mA output: 4 or 8 isolated repeated mA outputs, 0-22 mA, 0-100% FSD = 4-20 mA
  • Common inputs / outputs: Remote reset and remote inhibit inputs; 4 powered A/V outputs for alarms and fault, 3 common alarm outputs
  • Display: 7-inch color LCD touchscreen; 3 master indicator LEDs and 1 LED per channel (green: normal, yellow: fault / inhibit, red: alarm)
  • Sounder and language: Audible alarm 70 dB or more at 1 m; common reset / mute button; 9 languages (English, French, German, Italian, Dutch, Spanish, Portuguese, Russian, Chinese)
  • Power supply: AC 110/220 VAC, 50-60 Hz (manual switching) or DC 18 to 32 VDC (+/-10%, typical 24 VDC); the base and expansion units each require a power supply
  • Power consumption: Max. 105 W (including detector and external devices), max. 210 W with expansion unit
  • Backup battery: 22.2 V lithium ion battery, 2600 mAh (over 30 minutes for a typical system)
  • Datalogging and communication: Configuration, logged events and data on an SD card; Modbus TCP, web monitoring and Modbus RTU (options)
  • Size / weight: 426 mm x 300 mm x 156 mm (wall-mounted version); max. 8.5 kg (17 kg with expansion unit)
  • Housing: Polycarbonate ABS; 13 pre-drilled, sealed cable entries for PG16 / M20 glands
  • Environment: -10°C to +55°C continuous, up to 95% RH (non-condensing), IP65 and NEMA 4X; storage -25°C to +60°C
  • Approvals: EMC/RFI EN 50270:2015; LVD EN 61010-1:2010; CSA-C22.2 No. 61010-1-04; UL 61010-1 (3rd Edition) and 508; EN 50271:2010, EN 60079-29-1:2007/2016, EN 45544-1/-2/-3:2015, EN 50104:2010; IEC 61508:2010 Ed.2 SIL 2; Class I Division 2 Groups A, B, C, D or non-hazardous only; MED (marine, item 3.54)

Compatible detectors

The datasheet lists these Honeywell detectors for use with Touchpoint Plus: Sensepoint, Signalpoint, 705, Searchpoint Optima Plus, Sensepoint XCD, Series 3000 MkII / MkIII, RAEGuard II PID, IAQPoint2, XNX Universal Transmitter, Searchline Excel, E3Point, EC F9, IR F9. Other field devices are available on request and some devices are not available in all regions. The Sensepoint XCL datasheet names Touchpoint Plus as its compatible controller.

Order codes

Code descriptions follow CAD’s document. TPPL code structure per the datasheet: B = base unit, A / D = AC / DC power, W = wall mount, A2-A8 / V2-V8 / D4-D8 = mA / mV / mA + mV inputs, S / D = 12 / 24 relays, 4 / 8 = mA outputs, B = backup battery.

Order code Description
TPPLBAWA2NNNNNN TPPL Controller Basic, wall mount, AC115/220 150W, 2 x mA input
TPPLBAWA4NNNNNN TPPL Controller Basic, wall mount, AC115/220 150W, 4 x mA input
TPPLBAWA8NNNNNN TPPL Controller Basic, wall mount, AC115/220 150W, 8 x mA input
TPPLBAWV2NNNNNN TPPL Controller Basic, wall mount, AC115/220 150W, 2 x mV input
TPPLBAWV4NNNNNN TPPL Controller Basic, wall mount, AC115/220 150W, 4 x mV input
TPPLBAWV8NNNNNN TPPL Controller Basic, wall mount, AC115/220 150W, 8 x mV input
TPPLBAWD4NNNNNN TPPL Controller Basic, wall mount, AC115/220 150W, 2 x mA + 2 x mV input
TPPLBAWD8NNNNNN TPPL Controller Basic, wall mount, AC115/220 150W, 4 x mA + 4 x mV input
TPPLBAWA8S8BNNN TPPL Controller Basic, wall mount, AC115/220 150W, 8 x mA input with 12 x relay output, 8 x mA output, battery backup
TPPLBDWA8NNNNNN TPPL Controller Basic, wall mount, DC powered, 8 x mA input
TPPLBAWA8NNNNRN TPPL Controller Basic, wall mount, AC115/220 150W, 8 x mA input, MODBUS TCP+WEB monitoring
TPPLBAWA8NNNRNN TPPL Controller Basic, wall mount, AC115/220 150W, 8 x mA input, MODBUS RTU

Applications

Small-scale gas detection systems across a wide range of industries and applications, from mechanical rooms to chemical plants. Channel grouping and voting alarm logic can be configured without specialist knowledge; the unit can drive actuators, audible and visual alarms and connect to a higher-level management system through Modbus.

TECHNICAL SPECIFICATIONS

Specifications of Honeywell Touchpoint Plus Touchscreen Gas Controller

PARAMETER VALUE
Model Touchpoint Plus
Brand Honeywell
Product type Wall-mounted gas controller with touchscreen for small gas detection systems
Capacity Up to 8 channels with the base unit, up to 16 channels with an expansion unit
Input type 2- or 3-wire, mA or mV; 2 / 4 / 8-channel mA modules, 2 / 4 / 8-channel mV modules, or 2 mA + 2 mV, 4 mA + 4 mV; max. 15 W per channel, max. 40 W total (with dedicated A/V drive) / 68 W total (without)
Relay output 12 or 24 relay outputs, NO/C/NC changeover, 1.7 A at 30 VDC / 250 VAC, user-configurable energised / de-energised, latching / non-latching, time delay
4-20 mA output 4 or 8 isolated repeated mA outputs, 0-22 mA, 0-100% FSD = 4-20 mA
Common inputs / outputs Remote reset and remote inhibit inputs; 4 powered A/V outputs for alarms and fault, 3 common alarm outputs
Display 7-inch color LCD touchscreen; 3 master indicator LEDs and 1 LED per channel (green: normal, yellow: fault / inhibit, red: alarm)
Sounder and language Audible alarm 70 dB or more at 1 m; common reset / mute button; 9 languages (English, French, German, Italian, Dutch, Spanish, Portuguese, Russian, Chinese)
Power supply AC 110/220 VAC, 50-60 Hz (manual switching) or DC 18 to 32 VDC (+/-10%, typical 24 VDC); the base and expansion units each require a power supply
Power consumption Max. 105 W (including detector and external devices), max. 210 W with expansion unit
Backup battery 22.2 V lithium ion battery, 2600 mAh (over 30 minutes for a typical system)
Datalogging and communication Configuration, logged events and data on an SD card; Modbus TCP, web monitoring and Modbus RTU (options)
Size / weight 426 mm x 300 mm x 156 mm (wall-mounted version); max. 8.5 kg (17 kg with expansion unit)
Housing Polycarbonate ABS; 13 pre-drilled, sealed cable entries for PG16 / M20 glands
Environment -10°C to +55°C continuous, up to 95% RH (non-condensing), IP65 and NEMA 4X; storage -25°C to +60°C
Approvals EMC/RFI EN 50270:2015; LVD EN 61010-1:2010; CSA-C22.2 No. 61010-1-04; UL 61010-1 (3rd Edition) and 508; EN 50271:2010, EN 60079-29-1:2007/2016, EN 45544-1/-2/-3:2015, EN 50104:2010; IEC 61508:2010 Ed.2 SIL 2; Class I Division 2 Groups A, B, C, D or non-hazardous only; MED (marine, item 3.54)

Specifications may vary with the ordered configuration. Contact a CAD engineer for sizing to your actual operating conditions.

FAQ

Frequently asked questions about Touchpoint Plus

How does Touchpoint Plus differ from Unipoint and Touchpoint Pro?

Touchpoint Plus is a wall-mounted system with 8 channels (16 with an expansion unit), a 7-inch touchscreen and IP65 protection. Unipoint is a DIN-rail controller with one detector input per unit. Touchpoint Pro is a modular system with up to 64 input channels, a 5.7-inch touchscreen, ring network and redundancy.

Which input and output options does Touchpoint Plus offer?

2, 4 or 8 mA or mV input channels, or 2 mA + 2 mV, 4 mA + 4 mV; 12 or 24 relays; 4 or 8 mA outputs; Modbus RTU or Modbus TCP + WEB; AC or DC supply; optional backup battery.

Which certifications does Touchpoint Plus have?

SIL 2 to IEC 61508:2010 Ed.2, EMC EN 50270:2015, LVD EN 61010-1:2010, Class I Division 2 Groups A, B, C, D or non-hazardous only, and MED (marine). IP65 / NEMA 4X enclosure.

Used this product? Write a review

Your rating

20 to 1500 characters, no links.

CAD uses your name, company and text only to publish your review once approved. Your email is for CAD to check only; it is never shown or used for anything else.

Quote