The Honeywell T6360A5013 is a 230 Vac line-voltage room thermostat from the T6360 range, with SPDT changeover contacts (heating/cooling), a 10-30°C setpoint range and a dual diaphragm sensing element. ON/OFF control for heating, cooling or combined systems; the model is described for 2-pipe fan-coil control.

  • Brand Honeywell
  • Rated voltage 230 Vac, +/-10%, 50…60 Hz
  • Switch type S.P.D.T. (Heating/Cooling)
  • Contact rating (T6360A,B,C) 10(3) A terminal 3 (Heat); 6(2) A terminal 4 (Cool)
REQUEST A QUOTE DOWNLOAD DATASHEET (PDF)
  • Genuine products
  • Full CO/CQ
  • VAT invoice
  • Quote within 24 working hours

PRODUCT DESCRIPTION

Honeywell T6360A5013 Room Thermostat

• Dual diaphragm sensing element ensures close temperature control for all loads and applications
• Attractive modern styling makes this thermostat ideal for locating in the occupied space, particularly in offices or hotels
• All versions have heat anticipator, which improves temperature control in both heating and cooling operation
• Thermostat mounts directly onto a wall or conduit box
• Slide switches allow manual control of system operation and fan speed
• Auto heat/cool changeover possible (on some versions) by using pipe thermostat
• Optional extras:
– range stops F42006646-001 (20 per pack, enough for 10 thermostats)

Applications

The T4360/T6360 range are line-voltage room thermostats giving automatic ON/OFF control of gas valves, circulation pumps, relays and zone valves in heating, cooling or heating/cooling installations, where switching of up to 10 A (resistive) or 3 A (inductive) is required. The T6360 has changeover (SPDT) contacts for cooling or combined heating/cooling use.

Installation

  • Mounts directly on a wall or a conduit box; screws are supplied for both. An additional wall-plate is available for special mounting needs.
  • Install on an inside wall about 1.5 m above the floor, where there is good air circulation; avoid draughts, hot or cold air from water pipes, and radiant heat from the sun or appliances.
  • Terminals have conductor clamps and accept 2 wires of 1.0 to 2.5 mm². Double insulated, no earth wire is needed for operation. The installer must be a trained service engineer and must disconnect the power before installation; wire as shown to meet CE compliance.

Operation and durability

  • The sensing element is two circular flexible metal plates welded together, enclosing a small quantity of gas in liquid form whose pressure change operates a snap-acting switch.
  • The heat anticipator reduces overshoot and undershoot in systems with a high heating ramp rate.
  • Main switch life is above 100,000 operations at all loads; maximum differential 1.0°C at 20°C (typical 0.5°C).

Information to send for a quote

  • The full code (T6360A5013) and the quantity.
  • What is to be controlled (valve, pump, fan-coil fan…), the voltage and the load current so CAD can check the 10(3) A / 6(2) A contacts.

TECHNICAL SPECIFICATIONS

Specifications of Honeywell T6360

PARAMETER VALUE
Model T6360A5013
Brand Honeywell
Rated voltage 230 Vac, +/-10%, 50…60 Hz
Switch type S.P.D.T. (Heating/Cooling)
Contact rating (T6360A,B,C) 10(3) A terminal 3 (Heat); 6(2) A terminal 4 (Cool)
Setpoint range 10 – 30 °C
Typical differential 0.5 °C
Operating temperature 0 – 40 °C
Humidity 0 – 90% R.H. (non-condensing)
Certifications CE, RoHS, WEEE

Specifications may vary with the ordered configuration. Contact a CAD engineer for sizing to your actual operating conditions.

FAQ

Frequently asked questions about CAD-EL-231

How does the T6360 differ from the T4360?

According to Honeywell, the T4360 has single-pole single-throw (SPST) contacts for heating only, while the T6360 has SPDT changeover contacts for cooling or combined heating/cooling. Both are line-voltage 230 Vac.

What current can the T6360A5013 switch?

For the T6360A, B and C: 10(3) A on terminal 3 (heat) and 6(2) A on terminal 4 (cool); 230 Vac, 50-60 Hz. For larger loads, use an interposing relay or contactor.

Where in the room should the thermostat be placed?

On an inside wall about 1.5 m above the floor, in average air circulation; avoid draughts, hot or cold water pipes and direct sun. The operating temperature range of the unit is 0 to 40°C.

What should I send CAD to quote a T6360A5013?

Send the code T6360A5013, the quantity, and a description of what is to be controlled (valve, pump, fan-coil fan) with the voltage and load current. CAD quotes within 24 working hours.

Used this product? Write a review

Your rating

20 to 1500 characters, no links.

CAD uses your name, company and text only to publish your review once approved. Your email is for CAD to check only; it is never shown or used for anything else.

MORE IN ELECTRIC CONTROL AUTOMATION

RELATED PRODUCTS

View the full equipment catalogue
Quote