Honeywell BW Ultra Portable Multi-Gas Detector
BW Ultra is a Honeywell portable five-gas detector (O2, LEL, H2S, CO + one optional sensor), pump sampling up to 22.9 m, IP66/68, Ex ia IIC T4 Ga.
- Brand Honeywell
- Type Portable five-gas detector with pump, for confined-space sampling and monitoring
- Sensors Fast-response 1-Series sensors; four sensors O2, LEL, H2S, CO plus an optional fifth sensor
- Size 14.8 x 8.5 x 4.0 cm (5.8 x 3.3 x 1.6 in.)
- Genuine products
- Full CO/CQ
- VAT invoice
- Quote within 24 working hours
PRODUCT DESCRIPTION
Honeywell BW Ultra Portable Multi-Gas Detector
BW Ultra is a Honeywell portable five-gas detector designed for sampling and monitoring confined spaces before and after entry. Four sensors O2, LEL, H2S, CO plus an optional fifth sensor (PID, LEL IR, CO2 IR, SO2, NH3, H2, Cl2, NO2, HCN, NO or CO-H), fast-response 1-Series sensors, pump sampling up to 22.9 m, IP66/68, ATEX/IECEx Ex ia IIC T4 Ga intrinsic safety.
BW Ultra specifications
- Brand: Honeywell
- Type: Portable five-gas detector with pump, for confined-space sampling and monitoring
- Sensors: Fast-response 1-Series sensors; four sensors O2, LEL, H2S, CO plus an optional fifth sensor
- Size: 14.8 x 8.5 x 4.0 cm (5.8 x 3.3 x 1.6 in.)
- Weight: 411 g (14.5 oz.) with clip
- Operating temperature: -20°C to +50°C (-4°F to +131°F)
- Humidity: 5 – 95% RH (non-condensing) continuous
- Ingress protection: IP66/68
- Alarms: Visual, vibrating, audible (95 dB); Low, High, TWA, STEL, OL (over limit)
- Self-test: Activated detectors perform one internal diagnostic test every 24 hours (sensors, battery, circuitry)
- Typical battery life: 18 hours (14 hours with PID or IR sensor) at -20°C
- Pump draw: Sample from up to 22.9 m (75 ft)
- Connectivity: Bluetooth Low Energy (BLE) with the Honeywell Safety Communicator app; Honeywell TouchConnect to enter bump or calibration mode or change set-points
- Logging: 30 alarm events and 10 bump events; data logging 45 days based on 8-hour shifts every 15 seconds
- Languages: English, French, German, Portuguese, Spanish, Simplified Chinese, Russian
- Certifications and approvals: UL Class I, Div 1, Group A, B, C, D; Class I, Zone 0, Group IIC; ATEX II 1G Ex ia IIC T4 Ga; IECEx Ex ia IIC T4 Ga; CE
- Warranty: Instrument 3 years; sensors 3 years (2 years NH3, 1 year PID and Cl2); battery 2 years
Sensor ranges and resolution
| Gas | Range | Resolution |
|---|---|---|
| Oxygen (O2) | 0-25% vol. | 0.1% vol. |
| Combustible gases (LEL) | 0-100% LEL | 1% LEL |
| Combustible gases (IR)* | 0-5.00% vol. | 0.01% vol. |
| Hydrogen sulfide (H2S) | 0-100 ppm | 1 ppm / 0.1 ppm |
| Carbon monoxide (CO) | 0-2,000 ppm | 1 ppm |
| Carbon monoxide (low H2) (CO-H) | 0-1,000 ppm | 1 ppm |
| Sulfur dioxide (SO2) | 0-100 ppm | 0.1 ppm |
| Hydrogen (H2) | 0-2,000 ppm | 5 ppm |
| Carbon dioxide (CO2) | 0-50,000 ppm | 100 ppm |
| Ammonia (NH3) | 0-100 ppm | 1 ppm |
| Volatile organic compounds (VOC)** | 0-1,000 ppm | 1 ppm |
| Chlorine (Cl2) | 0-20 ppm | 0.1 ppm |
| Nitrogen dioxide (NO2) | 0-50 ppm | 0.1 ppm |
| Hydrogen cyanide (HCN) | 0-100 ppm | 0.1 ppm |
| Nitric oxide (NO) | 0-200 ppm | 1 ppm |
* The LEL IR combustible gas sensor used in BW Ultra cannot detect certain combustible gases including hydrogen and acetylene; review the application before choosing it. ** VOC: contact Honeywell for availability.
How to read a BW Ultra part number
The part number has 14 characters starting with HU, with one position per sensor as in the table below (from the CAD document, taken from the Honeywell datasheet).
| Position in the code | Values and meaning |
|---|---|
| HU | Designation for BW Ultra |
| 1st sensor (oxygen) | X1: oxygen sensor; 00: dummy sensor |
| 2nd sensor (LEL) | W1: 1 LEL 75 sensor; W2: 1 LEL 75C sensor; W3: 1 LEL 75M sensor; 00: dummy sensor |
| 3rd sensor (H2S) | H1: H2S sensor; 00: dummy sensor |
| 4th sensor (CO) | M1: CO sensor; 00: dummy sensor |
| 5th sensor (various) | Q1: PID sensor; W4: LEL IR sensor; B1: CO2 IR sensor; S2: SO2 sensor; A1: NH3 sensor; R1: H2 sensor; C1: Cl2 sensor; D1: NO2 sensor; Z1: HCN sensor; N1: NO sensor; M2: CO-H sensor; 00: dummy sensor |
| Enclosure colour (1 digit) | Y: yellow enclosure; B: black enclosure |
| Country code (1 digit) | Last digit of the code |
Applications
The Honeywell datasheet presents BW Ultra for sampling and monitoring confined spaces before and after entry, meeting safety regulations by detecting the required gases with an optional fifth sensor; it is compatible with Honeywell Connected Worker, SafetySuite and the IntelliDoX docking system.
TECHNICAL SPECIFICATIONS
Specifications of Honeywell BW Ultra Portable Multi-Gas Detector
| PARAMETER | VALUE |
|---|---|
| Model | BW Ultra |
| Brand | Honeywell |
| Type | Portable five-gas detector with pump, for confined-space sampling and monitoring |
| Sensors | Fast-response 1-Series sensors; four sensors O2, LEL, H2S, CO plus an optional fifth sensor |
| Size | 14.8 x 8.5 x 4.0 cm (5.8 x 3.3 x 1.6 in.) |
| Weight | 411 g (14.5 oz.) with clip |
| Operating temperature | -20°C to +50°C (-4°F to +131°F) |
| Humidity | 5 - 95% RH (non-condensing) continuous |
| Ingress protection | IP66/68 |
| Alarms | Visual, vibrating, audible (95 dB); Low, High, TWA, STEL, OL (over limit) |
| Self-test | Activated detectors perform one internal diagnostic test every 24 hours (sensors, battery, circuitry) |
| Typical battery life | 18 hours (14 hours with PID or IR sensor) at -20°C |
| Pump draw | Sample from up to 22.9 m (75 ft) |
| Connectivity | Bluetooth Low Energy (BLE) with the Honeywell Safety Communicator app; Honeywell TouchConnect to enter bump or calibration mode or change set-points |
| Logging | 30 alarm events and 10 bump events; data logging 45 days based on 8-hour shifts every 15 seconds |
| Languages | English, French, German, Portuguese, Spanish, Simplified Chinese, Russian |
| Certifications and approvals | UL Class I, Div 1, Group A, B, C, D; Class I, Zone 0, Group IIC; ATEX II 1G Ex ia IIC T4 Ga; IECEx Ex ia IIC T4 Ga; CE |
| Warranty | Instrument 3 years; sensors 3 years (2 years NH3, 1 year PID and Cl2); battery 2 years |
Specifications may vary with the ordered configuration. Contact a CAD engineer for sizing to your actual operating conditions.
FAQ
Frequently asked questions about BW Ultra
Which gases does BW Ultra detect?
Four sensors O2, LEL, H2S, CO plus an optional fifth sensor: PID, LEL IR, CO2 IR, SO2, NH3, H2, Cl2, NO2, HCN, NO or CO-H, as in the part-number table.
How long does the BW Ultra battery last and how far can it sample?
Typical battery life is 18 hours (14 hours with a PID or IR sensor) at -20°C. The pump samples from up to 22.9 m (75 ft).
What ingress protection and warranty does BW Ultra have?
IP66/68 ingress protection; ATEX II 1G Ex ia IIC T4 Ga, IECEx Ex ia IIC T4 Ga, Class I Div 1 Group A, B, C, D. Instrument warranty 3 years, sensors 3 years (2 years NH3, 1 year PID and Cl2), battery 2 years.