Honeywell FS24X Plus Triple IR (IR3) Flame Detector
FS24X Plus is a Honeywell triple IR (IR3) flame detector with a range up to 60 m, 4-20 mA / HART / Modbus outputs, ATEX, IECEx, SIL 2 and an IP66/67 enclosure.
- Brand Honeywell
- Product type Triple IR (IR3) flame detector for hydrocarbon and hydrogen fires
- Field of view 90° cone of vision; 120° cone (50% on-axis range)
- Sensitivity / range Low 15 m (50 ft), medium 30 m (100 ft), high 45 m (150 ft), very high 60 m (200 ft) to a 0.1 m2 (1 ft2) n-heptane fire; configured with Flame Manager
- Genuine products
- Full CO/CQ
- VAT invoice
- Quote within 24 working hours
PRODUCT DESCRIPTION
Honeywell FS24X Plus Triple IR (IR3) Flame Detector
FS24X Plus is a Honeywell triple IR (IR3) flame detector that responds to hydrocarbon and hydrogen fires over a wide field of view, with a detection range up to 60 m to a 0.1 m2 n-heptane fire. Solid-state, wide-band sensors allow detection through rain, fog and smoke. 4-20 mA, relay, HART and Modbus outputs; ATEX, IECEx, cFMus, SIL 2, FM3260 and EN54-10 certifications; IP66/67 enclosure.
How does FS24X Plus differ from FS20X and FSL100?
FS24X Plus differs from FS20X and FSL100 in sensing technology, range and housing. FS24X Plus: triple IR (IR3), 15-60 m range, typically responds in 5 seconds, aluminium or 316 stainless steel IP66/67 enclosure, ATEX / IECEx Ex db IIC T5, SIL 2, with HART and Modbus. FS20X: multi-spectrum UV / dual IR / visible (VIS), 15-60 m range, 3-5 second response at 30 m, IP66 enclosure, ATEX / IECEx Ex db IIC, HART as an optional module. FSL100: three versions, UV, UV/IR or IR3, in an IP65 GRP housing, 25 m (UV, UV/IR) or 35 m (IR3) range, 10-28 VDC supply, ATEX zone 2/22.
FS24X Plus specifications
- Brand: Honeywell
- Product type: Triple IR (IR3) flame detector for hydrocarbon and hydrogen fires
- Field of view: 90° cone of vision; 120° cone (50% on-axis range)
- Sensitivity / range: Low 15 m (50 ft), medium 30 m (100 ft), high 45 m (150 ft), very high 60 m (200 ft) to a 0.1 m2 (1 ft2) n-heptane fire; configured with Flame Manager
- Response time: Typically 5 seconds, 10 seconds maximum (FM witnessed); 3-5 seconds possible under specific conditions
- Operating voltage: 24 VDC nominal (18 to 32 VDC), regulated
- Power consumption: 1.8 W (nominal); 2.4 W (alarm); 12 W maximum with heater at 100% duty cycle
- Output relays: Alarm, fault and auxiliary: SPDT (NO/NC), de-energised / energised, latching / non-latching; rated 2 A at 32 VDC
- Analog output: 4-20 mA: source, sink or isolated
- Digital communications: RS-485: Modbus and FP2; USB: FP2; HART with handheld communicator or hardwired
- Operating temperature: -55°C to +75°C (North America: -50°C to +75°C); storage -55°C to +85°C (North America: -50°C to +85°C)
- Humidity range: 0 to 99% relative humidity or 100% condensing humidity for short periods
- Cable / conduit entries: 2 x M25 or 2 x ¾” NPT
- Enclosure material: Low-copper aluminium with marine-grade paint or 316 stainless steel
- Enclosure type: IP66 / IP67 (Type 4X)
- Tested fuels: n-Heptane, IPA, methane, butane, propane, ethanol, methanol, hydrogen, diesel, kerosene, JP-4
- Hazardous location certifications: ATEX: II 2 G Ex db IIC T5 Gb; II 2 D Ex tb IIIC T135°C Db IP66/67. IECEx: Ex db IIC T5 Gb; Ex tb IIIC T135°C Db IP66/67. cFMus: Class I Div 1 Groups A, B, C, D; Class II/III Div 1 Groups E, F, G, NEMA 4X. INMETRO
- Performance and safety certifications: FM3260; EN54-10: Class 1 (medium, high, very high sensitivity), Class 2 (low sensitivity); IEC 61508 SIL 2 certified by TUV Sud
- Pending: CU-TR, CCC and marine type approvals (ABS, Lloyds, BV, DNV): marked “pending” in the datasheet
Main features
A high-visibility LED halo ring shows status from a distance: green (normal), yellow (fault / warning), red (alarm). The SM4 mount is included as standard (a marine SM4-M mount is available). Set-up is by the Flame Manager PC app or HART; Flame Manager includes post-event analysis with the FirePic tool. It has window-clarity diagnostics, a test lamp for testing at a distance and an electro-optics module that can be swapped in the field. The datasheet describes the unit as calibration free.
Order codes
FS24XP- code structure per the datasheet: material (A aluminium, S stainless steel), entries (M = M25, N = ¾” NPT), approvals G (global), X reserved, installation (X standard mount + sunshade, M marine mount + sunshade).
| Order code | Description |
|---|---|
| FS24XP-ANGXX | FS24X Plus – 3IR – aluminium (AL) – ¾” NPT cable entries, kit includes mount and sunshade |
| FS24XP-AMGXX | FS24X Plus – 3IR – aluminium (AL) – M25 cable entries, kit includes mount and sunshade |
| FS24XP-SNGXX | FS24X Plus – 3IR – stainless steel (SS) – ¾” NPT cable entries, kit includes mount and sunshade |
| FS24XP-SMGXX | FS24X Plus – 3IR – stainless steel (SS) – M25 cable entries, kit includes mount and sunshade |
| FS24XP-ANGXM | FS24X Plus – 3IR – aluminium (AL) – ¾” NPT cable entries, kit includes marine mount and sunshade |
| FS24XP-AMGXM | FS24X Plus – 3IR – aluminium (AL) – M25 cable entries, kit includes marine mount and sunshade |
| FS24XP-SNGXM | FS24X Plus – 3IR – stainless steel (SS) – ¾” NPT cable entries, kit includes marine mount and sunshade |
| FS24XP-SMGXM | FS24X Plus – 3IR – stainless steel (SS) – M25 cable entries, kit includes marine mount and sunshade |
Applications
Flame detection in demanding industrial environments with hydrocarbon fires (heptane, IPA, methane, butane, propane, ethanol, methanol, diesel, kerosene, JP-4) or hydrogen fires. It operates from -55°C to +75°C with an IP66/67 enclosure, suited to outdoor mounting.
TECHNICAL SPECIFICATIONS
Specifications of Honeywell FS24X Plus
| PARAMETER | VALUE |
|---|---|
| Model | FS24X Plus |
| Brand | Honeywell |
| Product type | Triple IR (IR3) flame detector for hydrocarbon and hydrogen fires |
| Field of view | 90° cone of vision; 120° cone (50% on-axis range) |
| Sensitivity / range | Low 15 m (50 ft), medium 30 m (100 ft), high 45 m (150 ft), very high 60 m (200 ft) to a 0.1 m2 (1 ft2) n-heptane fire; configured with Flame Manager |
| Response time | Typically 5 seconds, 10 seconds maximum (FM witnessed); 3-5 seconds possible under specific conditions |
| Operating voltage | 24 VDC nominal (18 to 32 VDC), regulated |
| Power consumption | 1.8 W (nominal); 2.4 W (alarm); 12 W maximum with heater at 100% duty cycle |
| Output relays | Alarm, fault and auxiliary: SPDT (NO/NC), de-energised / energised, latching / non-latching; rated 2 A at 32 VDC |
| Analog output | 4-20 mA: source, sink or isolated |
| Digital communications | RS-485: Modbus and FP2; USB: FP2; HART with handheld communicator or hardwired |
| Operating temperature | -55°C to +75°C (North America: -50°C to +75°C); storage -55°C to +85°C (North America: -50°C to +85°C) |
| Humidity range | 0 to 99% relative humidity or 100% condensing humidity for short periods |
| Cable / conduit entries | 2 x M25 or 2 x ¾" NPT |
| Enclosure material | Low-copper aluminium with marine-grade paint or 316 stainless steel |
| Enclosure type | IP66 / IP67 (Type 4X) |
| Tested fuels | n-Heptane, IPA, methane, butane, propane, ethanol, methanol, hydrogen, diesel, kerosene, JP-4 |
| Hazardous location certifications | ATEX: II 2 G Ex db IIC T5 Gb; II 2 D Ex tb IIIC T135°C Db IP66/67. IECEx: Ex db IIC T5 Gb; Ex tb IIIC T135°C Db IP66/67. cFMus: Class I Div 1 Groups A, B, C, D; Class II/III Div 1 Groups E, F, G, NEMA 4X. INMETRO |
| Performance and safety certifications | FM3260; EN54-10: Class 1 (medium, high, very high sensitivity), Class 2 (low sensitivity); IEC 61508 SIL 2 certified by TUV Sud |
| Pending | CU-TR, CCC and marine type approvals (ABS, Lloyds, BV, DNV): marked "pending" in the datasheet |
Specifications may vary with the ordered configuration. Contact a CAD engineer for sizing to your actual operating conditions.
FAQ
Frequently asked questions about CAD-SF-410
How does FS24X Plus differ from FS20X and FSL100?
FS24X Plus uses triple IR (IR3), has a 15-60 m range, an IP66/67 enclosure, ATEX / IECEx Ex db IIC T5, SIL 2, and offers HART and Modbus. FS20X is a multi-spectrum UV / dual IR / visible detector with an IP66 enclosure. FSL100 comes as UV, UV/IR or IR3 in an IP65 GRP housing, with 25 m (UV, UV/IR) or 35 m (IR3) range and ATEX zone 2/22.
How far does FS24X Plus detect and how fast does it respond?
The range is configurable: 15 m, 30 m, 45 m or 60 m to a 0.1 m2 n-heptane fire. Response time is typically 5 seconds and 10 seconds at most (FM witnessed).
What outputs and certifications does FS24X Plus have?
4-20 mA output (source, sink or isolated), alarm / fault / auxiliary relays, RS-485 Modbus and FP2, USB FP2 and HART. Certifications: ATEX, IECEx, cFMus, INMETRO, FM3260, EN54-10 and IEC 61508 SIL 2.