Honeywell GasAlertMicro 5 Series Portable Multi-Gas Detectors
100% GENUINE
View larger
Honeywell GasAlertMicro 5 Series Portable Multi-Gas Detectors

Honeywell GasAlertMicro 5 Series Portable Multi-Gas Detectors

PRODUCT CODE
GasAlertMicro 5
BRAND
Honeywell

GasAlertMicro 5 is a Honeywell range of portable multi-gas detectors for up to 5 gases at once (O2, LEL, H2S, CO + 1), with PID (VOC) and IR (CO2) models, optional integral pump, IP 65/66, Ex ia IIC T4.

  • Brand Honeywell
  • Type Portable multi-gas detector monitoring up to five atmospheric hazards at once; three models: Micro 5 (toxic, electrochemical), Micro 5 PID (VOCs), Micro 5 IR (CO2)
  • Sensors Plug-in: electrochemical cell (toxic and oxygen), catalytic (LEL); PID model uses a 10.6 eV lamp for VOCs; IR model uses infrared for carbon dioxide
  • Size 14.5 x 7.4 x 3.8 cm (5.7 x 2.9 x 1.5 in.)
REQUEST A QUOTE DOWNLOAD DATASHEET (PDF)
  • Genuine products
  • Full CO/CQ
  • VAT invoice
  • Quote within 24 working hours

PRODUCT DESCRIPTION

Honeywell GasAlertMicro 5 Series Portable Multi-Gas Detectors

GasAlertMicro 5 is a Honeywell (BW Technologies) range of portable multi-gas detectors monitoring up to 5 atmospheric hazards at once (O2, LEL, H2S, CO and a fifth sensor), with a large display, raised buttons usable with gloves and an optional integral pump that switches quickly from diffusion to remote sampling up to 20 m. Three models: standard Micro 5 (toxic gases), Micro 5 PID (VOCs) and Micro 5 IR (CO2); IP 65/66, ATEX/IECEx Ex ia IIC T4 intrinsic safety.

How does GasAlertMicro 5 differ from the PID and IR models?

GasAlertMicro 5 detects H2S, CO, O2, SO2, PH3, NH3, NO2, HCN, Cl2, ClO2, O3 and combustibles (LEL) with electrochemical and catalytic sensors; battery life 20 hours. GasAlertMicro 5 PID adds a 10.6 eV photoionization (PID) sensor for volatile organic compounds (VOCs) alongside H2S, CO, O2, SO2, PH3, NH3, NO2, HCN, Cl2, ClO2, O3 and LEL; battery life 15 hours. GasAlertMicro 5 IR adds an infrared sensor for CO2 alongside H2S, CO, O2, SO2, NH3, O3 and LEL; battery life 15 hours. The models are not interchangeable because of board and sensor configuration (for example a PID sensor cannot be used in an IR-configured unit).

GasAlertMicro 5 specifications

  • Brand: Honeywell
  • Type: Portable multi-gas detector monitoring up to five atmospheric hazards at once; three models: Micro 5 (toxic, electrochemical), Micro 5 PID (VOCs), Micro 5 IR (CO2)
  • Sensors: Plug-in: electrochemical cell (toxic and oxygen), catalytic (LEL); PID model uses a 10.6 eV lamp for VOCs; IR model uses infrared for carbon dioxide
  • Size: 14.5 x 7.4 x 3.8 cm (5.7 x 2.9 x 1.5 in.)
  • Weight: 370 g (13.1 oz.)
  • Temperature: -20°C to +50°C (-4°F to +122°F); -10°C to +40°C (14°F to +104°F) for PID
  • Alarms: Visual, vibrating, audible (95 dB); Low, High, STEL, TWA, OL (over limit)
  • Pump: Optional integral pump (quick switch between diffusion and pump); sample from up to 20 m (66 ft)
  • Typical battery life: AA alkaline or hot-swappable rechargeable pack; Micro 5: 20 hours (alkaline and rechargeable); PID and IR: 15 hours (based on a 5-gas instrument in diffusion mode at +20°C)
  • Languages: Five languages: English, French, German, Spanish and Portuguese; passcode protection of settings
  • Ratings: IP 65/66
  • Certifications and approvals: Class I, Div. 1, Gr. A, B, C, D; American Bureau of Shipping (toxic and PID models); ATEX II 1 G Ga Ex ia IIC T4*; ATEX II 2 G Ex d ia IIC T4* (IR model only); IECEx Ga Ex ia IIC T4*; IECEx Ex d ia IIC T4* (IR model only). *Temperature codes may vary with the installed batteries
  • Warranty: Full two-year warranty including sensors (1 year NH3, Cl2, O3, ClO2 and PID lamp)

GasAlertMicro 5 order codes

18 codes from the CAD document (toxic / electrochemical model). Descriptions follow the document: rechargeable or alkaline power, with or without pump, yellow or black housing. Codes for the PID and IR models are not in the CAD document.

Order code Description
M5-XWSY-R-D-D-Y-N-00 %LEL, O2, H2S, CO, SO2 – rechargeable battery, yellow housing
M5-XWSY-R-P-D-Y-N-00 %LEL, O2, H2S, CO, SO2 – rechargeable battery and pump, yellow housing
M5-XWAY-R-D-D-Y-N-00 %LEL, O2, H2S, CO, NH3 – rechargeable battery, yellow housing
M5-XWAY-R-P-D-Y-N-00 %LEL, O2, H2S, CO, NH3 – rechargeable battery and pump, yellow housing
M5-XWCY-R-D-D-Y-N-00 %LEL, O2, H2S, CO, Cl2 – rechargeable battery, yellow housing
M5-XWCY-R-P-D-Y-N-00 %LEL, O2, H2S, CO, Cl2 – rechargeable battery and pump, yellow housing
M5-XW0Y-A-P-D-Y-N-00 %LEL, O2, H2S, CO – alkaline batteries and pump, yellow housing
M5-XW0Y-R-D-D-Y-N-00 %LEL, O2, H2S, CO – rechargeable battery, yellow housing
M5-XW0Y-R-P-D-Y-N-00 %LEL, O2, H2S, CO – rechargeable battery and pump, yellow housing
M5-XWSY-R-D-D-B-N-00 %LEL, O2, H2S, CO, SO2 – rechargeable battery, black housing
M5-XWSY-R-P-D-B-N-00 %LEL, O2, H2S, CO, SO2 – rechargeable battery and pump, black housing
M5-XWAY-R-D-D-B-N-00 %LEL, O2, H2S, CO, NH3 – rechargeable battery, black housing
M5-XWAY-R-P-D-B-N-00 %LEL, O2, H2S, CO, NH3 – rechargeable battery and pump, black housing
M5-XWCY-R-D-D-B-N-00 %LEL, O2, H2S, CO, Cl2 – rechargeable battery, black housing
M5-XWCY-R-P-D-B-N-00 %LEL, O2, H2S, CO, Cl2 – rechargeable battery and pump, black housing
M5-XW0Y-A-P-D-B-N-00 %LEL, O2, H2S, CO – alkaline batteries and pump, black housing
M5-XW0Y-R-D-D-B-N-00 %LEL, O2, H2S, CO – rechargeable battery, black housing
M5-XW0Y-R-P-D-B-N-00 %LEL, O2, H2S, CO – rechargeable battery and pump, black housing

Sensor ranges and resolution

Gas Measuring range Default resolution High resolution
H2S 0-500 ppm 1.0 ppm 0.1 ppm
CO 0-999 ppm 1.0 ppm N/A
TwinTox (H2S) 0-500 ppm 1.0 ppm 0.1 ppm
TwinTox (CO) 0-500 ppm 1.0 ppm N/A
O2 0-30.0% 0.1% N/A
SO2 0-150 ppm 1.0 ppm 0.1 ppm
PH3 0-5.0 ppm 1.0 ppm 0.1 ppm
NH3 0-100 ppm 1.0 ppm 0.1 ppm
NO2 0-99.9 ppm 1.0 ppm 0.1 ppm
HCN 0-30.0 ppm 1.0 ppm 0.1 ppm
Cl2 0-50.0 ppm 1.0 ppm 0.1 ppm
ClO2 0-1.0 ppm 0.1 ppm 0.01 ppm
O3 0-1.0 ppm 0.1 ppm 0.01 ppm
PID (VOC) 0-1000 ppm 1 ppm N/A
IR (CO2) 0-50,000 ppm; 0-5.0% v/v 50 ppm; 0.01% N/A
Khí cháy / Combustible gases 0-100% LEL; 0-5.0% v/v 1%; 0.1% N/A

Applications

The Honeywell datasheet lists confined space entry, wastewater plants (Cl2, NH3, ClO2), steel / iron production (NO2), pulp and paper (Cl2), food and beverage (NH3 from refrigerants, ice production; PH3 from fumigation) and construction; the PID model for VOCs and the IR model for CO2 (wineries and breweries, agriculture, cold storage, wastewater treatment, landfills and more). Compatible with the MicroDock II automatic test and calibration station.

TECHNICAL SPECIFICATIONS

Specifications of Honeywell GasAlertMicro 5 Series Portable Multi-Gas Detectors

PARAMETER VALUE
Model GasAlertMicro 5
Brand Honeywell
Type Portable multi-gas detector monitoring up to five atmospheric hazards at once; three models: Micro 5 (toxic, electrochemical), Micro 5 PID (VOCs), Micro 5 IR (CO2)
Sensors Plug-in: electrochemical cell (toxic and oxygen), catalytic (LEL); PID model uses a 10.6 eV lamp for VOCs; IR model uses infrared for carbon dioxide
Size 14.5 x 7.4 x 3.8 cm (5.7 x 2.9 x 1.5 in.)
Weight 370 g (13.1 oz.)
Temperature -20°C to +50°C (-4°F to +122°F); -10°C to +40°C (14°F to +104°F) for PID
Alarms Visual, vibrating, audible (95 dB); Low, High, STEL, TWA, OL (over limit)
Pump Optional integral pump (quick switch between diffusion and pump); sample from up to 20 m (66 ft)
Typical battery life AA alkaline or hot-swappable rechargeable pack; Micro 5: 20 hours (alkaline and rechargeable); PID and IR: 15 hours (based on a 5-gas instrument in diffusion mode at +20°C)
Languages Five languages: English, French, German, Spanish and Portuguese; passcode protection of settings
Ratings IP 65/66
Certifications and approvals Class I, Div. 1, Gr. A, B, C, D; American Bureau of Shipping (toxic and PID models); ATEX II 1 G Ga Ex ia IIC T4*; ATEX II 2 G Ex d ia IIC T4* (IR model only); IECEx Ga Ex ia IIC T4*; IECEx Ex d ia IIC T4* (IR model only). *Temperature codes may vary with the installed batteries
Warranty Full two-year warranty including sensors (1 year NH3, Cl2, O3, ClO2 and PID lamp)

Specifications may vary with the ordered configuration. Contact a CAD engineer for sizing to your actual operating conditions.

FAQ

Frequently asked questions about GasAlertMicro 5

How do GasAlertMicro 5, the PID model and the IR model differ?

The standard model detects toxic gases, oxygen and LEL with electrochemical / catalytic sensors (20-hour battery). The PID model adds a 10.6 eV PID sensor for VOCs (15-hour battery). The IR model adds an infrared sensor for CO2 (15-hour battery). The models are not interchangeable.

Can GasAlertMicro 5 sample remotely?

Yes, with the integral pump option: it samples from up to 20 m (66 ft) and switches quickly between diffusion and pump in the field.

What ingress protection and warranty does GasAlertMicro 5 have?

IP 65/66; ATEX II 1 G Ex ia IIC T4, IECEx Ex ia IIC T4, Class I Div. 1 Gr. A, B, C, D approvals. Full two-year warranty including sensors (1 year NH3, Cl2, O3, ClO2 and PID lamp).

Used this product? Write a review

Your rating

20 to 1500 characters, no links.

CAD uses your name, company and text only to publish your review once approved. Your email is for CAD to check only; it is never shown or used for anything else.

Quote