Midas is a Honeywell single-point sample-draw gas monitoring system for 48 toxic and flammable gas entries, remote sampling up to 30 m, 3 relays, Modbus / TCP Ethernet / PoE.

  • Brand Honeywell
  • Type Single-point sample-draw gas monitoring system; a separate sensor cartridge for each gas, covering toxic and flammable gases
  • Gases and ranges 48 gas / range entries, see the table below (per datasheet)
  • Transmitter size (unit with sensor) 150 x 65 x 153 mm (5.91 x 2.56 x 6.02 in); weight 0.8 kg (1.76 lb)
REQUEST A QUOTE DOWNLOAD DATASHEET (PDF)
  • Genuine products
  • Full CO/CQ
  • VAT invoice
  • Quote within 24 working hours

PRODUCT DESCRIPTION

Honeywell Midas Gas Monitoring System

Midas is a Honeywell single-point sample-draw gas monitoring system using a separate sensor cartridge for each gas, covering toxic and flammable gases. The datasheet lists 48 gas / range entries, from ammonia, hydrogen chloride and hydrogen sulfide to silane, arsine and nitrogen trifluoride (which needs a pyrolyzer). Compact 150 x 65 x 153 mm transmitter, 24 VDC or 48 VDC over PoE supply, 3 relays, 0 to 21 mA analog output, Modbus, TCP Ethernet and Lonworks communications; remote sampling up to 30 m (FEP tubing) at a 500 mL/min flow rate.

How to choose a Midas cartridge

Each gas uses its own sensor cartridge, with part numbers starting MIDAS-E; some cartridges serve several gases (for example MIDAS-E-HCL for BCl3, dichlorosilane, HBr and HCl). Gases marked ** need the Midas Pyrolyzer. CAD’s list has no separate order codes for Midas, so the table below comes from the datasheet.

Midas specifications

  • Type: Single-point sample-draw gas monitoring system; a separate sensor cartridge for each gas, covering toxic and flammable gases
  • Gases and ranges: 48 gas / range entries, see the table below (per datasheet)
  • Transmitter size (unit with sensor): 150 x 65 x 153 mm (5.91 x 2.56 x 6.02 in); weight 0.8 kg (1.76 lb)
  • NF3 Pyrolyzer: 70 x 63 x 85 mm; 0.41 kg
  • High-temperature PFC Pyrolyzer: 100 x 101 x 140 mm; 1.36 kg
  • OP3 Pyrolyzer: 132 x 60 x 98 mm; 1.20 kg
  • NP1 Pyrolyzer: 128 x 65 x 134 mm; 0.81 kg
  • Operating voltage: 24 VDC, -15 to +10 %; or 48 VDC via Power over Ethernet (PoE)
  • Power consumption: Transmitter unit < 5 W; with pyrolyzer (option) < 12.95 W; with Lonworks < 8 W; with Lonworks and pyrolyzer < 15.95 W
  • Display: Alarm, power and fault LEDs; 4-digit alphanumeric LCD with separate units, flow rate bar graph and icon-driven indicators; 4-button keypad
  • Relays: 3 relays for Alarm 1, Alarm 2 and Fault rated 30 VDC, 1 A or 125 VAC, 0.5 A; configurable NO or NC, latched or unlatched
  • Analog output: 3 wire sink, 3 wire source or 4 wire fully isolated, 0 to 21 mA
  • Digital communications: Modbus, TCP Ethernet, Power over Ethernet (PoE), Lonworks; service port RS232C (PPP protocol)
  • Transport system: Flow rate 500 mL/min; transport time 2 to 30 seconds maximum; sample line tubing 0.125 in ID x 0.25 in OD, up to 100 ft (30 m) with FEP tubing; exhaust line tubing 0.25 in ID x 0.375 in OD, up to 100 ft (30 m); in-line air filter required at an ambient point
  • Operating temperature: Unit with sensor: 0 to 40°C (32 to 104°F); unit with sensor and pyrolyzer: 0 to 30°C (32 to 86°F)
  • Wiring: 4-20 mA: 2 wire, 14 AWG maximum; digital: CAT5 cable or equivalent, RJ45 connector
  • Remote access: Option for PC / PDA Internet browser access via Ethernet
  • Mounting: Wall mounted using pre-drilled holes on chassis; options for DIN rail or vertical bracket mounting; painted steel cover, zinc plated steel chassis / mounting bracket
  • Warranty: Transmitter unit 1 year; sensor cartridge 1 year standard, 2 years extended warranty; expected pyrolyzer life MIDAS-T-00P 1 year, MIDAS-T-NP1 2 years
  • Certification / standards: CE marked; EN 50270:2006 (Type 2) and EN 61000-6-4:2007; ETL approved UL 61010-1 Ed:3; IEEE 802.3af-2003

Gases, ranges and sensor part numbers

Gas Chemical formula Range Sensor part number
Ammonia NH3 0-100 ppm MIDAS-E-NH3
Arsine AsH3 0-200 ppb MIDAS-E-ASH
Boron Trichloride BCl3 0-8 ppm MIDAS-E-HCL
Boron Trifluoride BF3 0-8 ppm MIDAS-E-HFX
Boron Trifluoride (Low Level) BF3 0-2 ppm MIDAS-E-HFL
Bromine Br2 0-0.4 ppm MIDAS-E-BR2
Butane n-C4H10 0~100 %LEL MIDAS-E-LEB
Carbon Dioxide CO2 0-2.0% MIDAS-E-CO2
Carbon Monoxide CO 0-100 ppm MIDAS-E-COX
Carbon Monoxide (Low H2 interference) CO 0-100 ppm MIDAS-E-COH
Chlorine Cl2 0-2 ppm MIDAS-E-HAL
Chlorine Dioxide ClO2 0-0.4 ppm MIDAS-E-BR2
Diborane B2H6 0-400 ppb MIDAS-E-B2H
Dichlorosilane H2Cl2Si 0-8 ppm MIDAS-E-HCL
Difluoromethane** CH2F2 0-240 ppm MIDAS-E-XCF
Disilane Si2H6 0-20 ppm MIDAS-E-SHX
Ethylene C2H4 0~100 %LEL MIDAS-E-LEL
Fluorine F2 0-4 ppm MIDAS-E-HAL
Germane GeH4 0-800 ppb MIDAS-E-ASH
Hexafluorobutadiene** C4F6 0-40 ppm MIDAS-E-CFX
Hydrogen (%LEL) H2 0~100 %LEL MIDAS-E-LEL*
Hydrogen (ppm) H2 0-1000 ppm MIDAS-E-H2X
Hydrogen Bromide HBr 0-8 ppm MIDAS-E-HCL
Hydrogen Chloride HCl 0-8 ppm MIDAS-E-HCL
Hydrogen Cyanide HCN 0-20 ppm MIDAS-E-HCN
Hydrogen Fluoride HF 0-12 ppm MIDAS-E-HFX
Hydrogen Fluoride (Low Level) HFL 0-2 ppm MIDAS-E-HFL
Hydrogen Sulfide H2S 0-40 ppm MIDAS-E-H2S
Methane (%LEL) CH4 0~100 %LEL MIDAS-E-LEL*
Methyl Fluoride** CH3F 0-120 ppm MIDAS-E-XHF
Nitric Oxide NO 0-100 ppm MIDAS-E-NOX
Nitrogen Dioxide NO2 0-12 ppm MIDAS-E-NO2
Nitrogen Trifluoride** NF3 0-40 ppm MIDAS-E-HFX for 00P, XHF for NP1
Octane n-C8H18 0~100 %LEL MIDAS-E-LEO
Octofluorocyclopentene** C5F8 0-40 ppm MIDAS-E-XCF
Oxygen O2 0~25% v/v MIDAS-E-O2X
Ozone O3 0-0.7 ppm MIDAS-E-O3H
Ozone (Low Level) O3 0-0.4 ppm MIDAS-E-O3X
Phosphine PH3 0-1200 ppb MIDAS-E-PH3
Propane C3H8 0~100 %LEL MIDAS-E-LEX
Propylene C3H6 0~100 %LEL MIDAS-E-LEL
R134a C2H2F4 0-1000 ppm MIDAS-E-XCF
Silane SiH4 0-20 ppm MIDAS-E-SHX
Silane (Low Level) SiH4 0-2 ppm MIDAS-E-SHL
Sulfur Dioxide SO2 0-8 ppm MIDAS-E-SO2
Tetra Ethyl Ortho Silicate TEOS 0-40 ppm MIDAS-E-TEO
Tungsten Hexafluoride WF6 0-12 ppm MIDAS-E-HFX
Tungsten Hexafluoride (Low Level) WF6 0-2 ppm MIDAS-E-HFL

* The MIDAS-E-LEL cartridge carries a 2-year warranty but can be calibrated up to 5 years. ** These gases require the Midas Pyrolyzer. Midas detectors are not ETL approved for monitoring in or sampling from classified areas above 25 %LEL.

Applications

Sample-draw monitoring for the toxic and flammable gases listed in the datasheet: gas is drawn through sample tubing up to 30 m, measured at the transmitter, shown on the local display and sent to the control system or over the network.

TECHNICAL SPECIFICATIONS

Specifications of Honeywell Midas Gas Monitoring System

PARAMETER VALUE
Model Midas
Brand Honeywell
Type Single-point sample-draw gas monitoring system; a separate sensor cartridge for each gas, covering toxic and flammable gases
Gases and ranges 48 gas / range entries, see the table below (per datasheet)
Transmitter size (unit with sensor) 150 x 65 x 153 mm (5.91 x 2.56 x 6.02 in); weight 0.8 kg (1.76 lb)
NF3 Pyrolyzer 70 x 63 x 85 mm; 0.41 kg
High-temperature PFC Pyrolyzer 100 x 101 x 140 mm; 1.36 kg
OP3 Pyrolyzer 132 x 60 x 98 mm; 1.20 kg
NP1 Pyrolyzer 128 x 65 x 134 mm; 0.81 kg
Operating voltage 24 VDC, -15 to +10 %; or 48 VDC via Power over Ethernet (PoE)
Power consumption Transmitter unit < 5 W; with pyrolyzer (option) < 12.95 W; with Lonworks < 8 W; with Lonworks and pyrolyzer < 15.95 W
Display Alarm, power and fault LEDs; 4-digit alphanumeric LCD with separate units, flow rate bar graph and icon-driven indicators; 4-button keypad
Relays 3 relays for Alarm 1, Alarm 2 and Fault rated 30 VDC, 1 A or 125 VAC, 0.5 A; configurable NO or NC, latched or unlatched
Analog output 3 wire sink, 3 wire source or 4 wire fully isolated, 0 to 21 mA
Digital communications Modbus, TCP Ethernet, Power over Ethernet (PoE), Lonworks; service port RS232C (PPP protocol)
Transport system Flow rate 500 mL/min; transport time 2 to 30 seconds maximum; sample line tubing 0.125 in ID x 0.25 in OD, up to 100 ft (30 m) with FEP tubing; exhaust line tubing 0.25 in ID x 0.375 in OD, up to 100 ft (30 m); in-line air filter required at an ambient point
Operating temperature Unit with sensor: 0 to 40°C (32 to 104°F); unit with sensor and pyrolyzer: 0 to 30°C (32 to 86°F)
Wiring 4-20 mA: 2 wire, 14 AWG maximum; digital: CAT5 cable or equivalent, RJ45 connector
Remote access Option for PC / PDA Internet browser access via Ethernet
Mounting Wall mounted using pre-drilled holes on chassis; options for DIN rail or vertical bracket mounting; painted steel cover, zinc plated steel chassis / mounting bracket
Warranty Transmitter unit 1 year; sensor cartridge 1 year standard, 2 years extended warranty; expected pyrolyzer life MIDAS-T-00P 1 year, MIDAS-T-NP1 2 years
Certification / standards CE marked; EN 50270:2006 (Type 2) and EN 61000-6-4:2007; ETL approved UL 61010-1 Ed:3; IEEE 802.3af-2003

Specifications may vary with the ordered configuration. Contact a CAD engineer for sizing to your actual operating conditions.

FAQ

Frequently asked questions about CAD-SF-431

Which gases can the Midas measure?

The datasheet lists 48 gas / range entries, including ammonia, arsine, boron trichloride, chlorine, carbon monoxide, hydrogen chloride, hydrogen fluoride, hydrogen sulfide, oxygen, ozone, phosphine, silane, sulfur dioxide, nitrogen trifluoride and flammables such as methane, butane and propane (0-100 %LEL). Some gases need the Midas Pyrolyzer.

How far can the Midas sample remotely and what outputs does it have?

Sample tubing up to 30 m (100 ft) with FEP tubing, 500 mL/min flow rate, 2 to 30 seconds transport time. 0 to 21 mA analog output, 3 relays, Modbus, TCP Ethernet, Power over Ethernet and Lonworks.

How is the Midas powered and what warranty does it have?

24 VDC (-15 to +10 %) or 48 VDC via PoE. Transmitter unit warranty 1 year; sensor cartridge 1 year standard or 2 years extended.