Honeywell MultiRAE Pro Wireless Radiation and Chemical Detector
100% GENUINE
View larger
Honeywell MultiRAE Pro Wireless Radiation and Chemical Detector

Honeywell MultiRAE Pro Wireless Radiation and Chemical Detector

PRODUCT CODE
CAD-SF-402
BRAND
Honeywell
PRODUCT LINE
MultiRAE

MultiRAE Pro is a Honeywell portable wireless multi-threat monitor for gamma radiation, VOCs, toxic gases, oxygen and combustibles, with over 25 swappable sensors, built-in pump, IP-65, Ex ia IIC T4 Ga.

  • Brand Honeywell
  • Type Portable wireless multi-threat radiation and chemical detector with built-in pump
  • Sensors Over 25 intelligent interchangeable field-replaceable sensors: gamma radiation, ppb and ppm PID for VOCs, electrochemical for toxic gases and oxygen, combustible LEL and NDIR, CO2 NDIR; up to 6 threat types at a time
  • Size 193 x 96.5 x 66 mm (7.6" H x 3.8" W x 2.6" D)
REQUEST A QUOTE DOWNLOAD DATASHEET (PDF)
  • Genuine products
  • Full CO/CQ
  • VAT invoice
  • Quote within 24 working hours

PRODUCT DESCRIPTION

Honeywell MultiRAE Pro Wireless Radiation and Chemical Detector

MultiRAE Pro is a Honeywell (RAE Systems) portable wireless multi-threat monitor that detects gamma radiation and toxic industrial chemicals (TICs/TIMs), VOCs, oxygen, toxic gases and combustibles at the same time, up to 6 threat types at once. Over 25 intelligent field-swappable sensors, built-in pump, Man Down Alarm, IP-65, ATEX/IECEx Ex ia IIC T4 Ga intrinsic safety, MIL-STD-810G and 461F compliant. Model number PGM-6248.

MultiRAE Pro specifications

  • Brand: Honeywell
  • Type: Portable wireless multi-threat radiation and chemical detector with built-in pump
  • Sensors: Over 25 intelligent interchangeable field-replaceable sensors: gamma radiation, ppb and ppm PID for VOCs, electrochemical for toxic gases and oxygen, combustible LEL and NDIR, CO2 NDIR; up to 6 threat types at a time
  • Size: 193 x 96.5 x 66 mm (7.6″ H x 3.8″ W x 2.6″ D)
  • Weight: 880 g (31 oz.)
  • Battery: Rechargeable Li-ion (~12 hr runtime, < 6 hr recharge); extended-duration Li-ion (~18 hr runtime, < 9 hr recharge); alkaline adapter with 4 x AA batteries (~6 hr runtime). Figures for non-wireless monitors
  • Display: Monochrome graphical LCD 128 x 160 with backlighting, automatic screen flip; 3 keys (Mode, Y/+, N/-)
  • Sampling: Built-in pump, average flow rate 250 cc/min, auto shutoff in low-flow conditions
  • Alarms: Wireless remote alarm notification; multi-tone audible (95 dB at 30 cm), vibration, flashing bright red LEDs, on-screen indication; Man Down Alarm with pre-alarm
  • Datalogging: Continuous, 6 months for 5 sensors at 1-minute intervals, 24/7; user-configurable interval from 1 to 3,600 seconds
  • Wireless: Built-in RF modem (optional): ISM license-free band Sub 1 GHz and Wi-Fi 802.11 b/g; about 100 m to RAELink3 [Z1] Mesh modem or Access Point, about 200 m to EchoView Host, RAEMesh Reader or RAEPoint
  • Operating temperature: -20°C to 50°C (-4°F to 122°F)
  • Humidity: 0% to 95% relative humidity (non-condensing)
  • Ingress protection: IP-65
  • Safety certifications: CSA: Class I, Division 1, Groups A, B, C, D, T4; Class II, Division 1, Groups E, F, G T85°C; ATEX: 0575 II 1G Ex ia IIC T4 Ga, 2G Ex ia d IIC T4 Gb with IR sensor installed, I M1 Ex ia I Ma; IECEx: Ex ia IIC T4 Ga, Ex ia d IIC T4 Gb with IR sensor installed, Ex ia I Ma; IECEx/ANZEx: Ex ia IIC T4 Ga
  • Performance tests: MIL-STD-810G and 461F compliant; LEL CSA C22.2 No. 152, ISA-12.13.01
  • Languages: 19 languages: Arabic, Chinese, Czech, Danish, Dutch, English, French, German, Indonesian, Italian, Japanese, Korean, Norwegian, Polish, Portuguese, Russian, Spanish, Swedish, Turkish
  • Model number: PGM-6248
  • Warranty: Four years on liquid O2 sensors; three years on CO and H2S sensors; two years on non-consumable components and catalytic LEL sensors; one year on all other sensors, pump, battery and consumable parts

Sensor ranges and resolution

Group Sensor Range Resolution
Radiation Gamma radiation 0-20,000 μRem/h (liều suất) 1cc CsI (Tl) scintillator with photodiode
PID VOC 10.6 eV (extended range) 0-5,000 ppm 0.1 ppm
PID VOC 10.6 eV (ppb) 0-2,000 ppm 10 ppb
Combustible Catalytic LEL 0-100% LEL 1% LEL
Combustible NDIR (0-100% LEL methane) 0-100% LEL 1% LEL
Combustible NDIR (0-100% vol. methane) 0-100% Vol. 0.1% Vol.
CO2 Carbon dioxide (CO2) NDIR 0-50,000 ppm 100 ppm
Electrochemical Ammonia (NH3) 0-100 ppm 1 ppm
Electrochemical Carbon monoxide (CO) 0-500 ppm 1 ppm
Electrochemical CO, extended range 0-2,000 ppm 10 ppm
Electrochemical CO, H2-compensated 0-2,000 ppm 10 ppm
Electrochemical CO + H2S combo (CO) 0-500 ppm 1 ppm
Electrochemical CO + H2S combo (H2S) 0-200 ppm 0.1 ppm
Electrochemical Chlorine (Cl2) 0-50 ppm 0.1 ppm
Electrochemical Chlorine dioxide (ClO2) 0-1 ppm 0.03 ppm
Electrochemical Ethylene oxide (ETO-A) 0-100 ppm 0.5 ppm
Electrochemical Ethylene oxide (ETO-B) 0-10 ppm 0.1 ppm
Electrochemical Formaldehyde (HCHO) 0-10 ppm 0.05 ppm
Electrochemical Hydrogen cyanide (HCN) 0-50 ppm 0.5 ppm
Electrochemical Hydrogen sulfide (H2S) 0-100 ppm 0.1 ppm
Electrochemical Methyl mercaptan (CH3-SH) 0-10 ppm 0.1 ppm
Electrochemical Nitric oxide (NO) 0-250 ppm 0.5 ppm
Electrochemical Nitrogen dioxide (NO2) 0-20 ppm 0.1 ppm
Electrochemical Oxygen (O2) 0-30% Vol. 0.1% Vol.
Electrochemical Oxygen (LIQ O2) 0-30% Vol. 0.1% Vol.
Electrochemical Phosphine (PH3) 0-20 ppm 0.1 ppm
Electrochemical Phosphine (PH3 H) 0-20 ppm 0.1 ppm
Electrochemical Sulfur dioxide (SO2) 0-20 ppm 0.1 ppm

The monitor comes in wireless and non-wireless versions; order codes depend on the configuration (monitor, accessories, sampling and calibration kits, gas, sensors, replacement parts): contact CAD. A two-gas combination sensor is required for a 6-threat configuration.

Applications

The Honeywell datasheet lists civil defense (search and rescue), homeland security, HazMat response, military, semiconductor manufacturing and environmental use. The monitor works with the AutoRAE 2 automatic test and calibration system and Honeywell SafetySuite device management.

TECHNICAL SPECIFICATIONS

Specifications of Honeywell MultiRAE

PARAMETER VALUE
Model MultiRAE Pro
Brand Honeywell
Type Portable wireless multi-threat radiation and chemical detector with built-in pump
Sensors Over 25 intelligent interchangeable field-replaceable sensors: gamma radiation, ppb and ppm PID for VOCs, electrochemical for toxic gases and oxygen, combustible LEL and NDIR, CO2 NDIR; up to 6 threat types at a time
Size 193 x 96.5 x 66 mm (7.6" H x 3.8" W x 2.6" D)
Weight 880 g (31 oz.)
Battery Rechargeable Li-ion (~12 hr runtime, < 6 hr recharge); extended-duration Li-ion (~18 hr runtime, < 9 hr recharge); alkaline adapter with 4 x AA batteries (~6 hr runtime). Figures for non-wireless monitors
Display Monochrome graphical LCD 128 x 160 with backlighting, automatic screen flip; 3 keys (Mode, Y/+, N/-)
Sampling Built-in pump, average flow rate 250 cc/min, auto shutoff in low-flow conditions
Alarms Wireless remote alarm notification; multi-tone audible (95 dB at 30 cm), vibration, flashing bright red LEDs, on-screen indication; Man Down Alarm with pre-alarm
Datalogging Continuous, 6 months for 5 sensors at 1-minute intervals, 24/7; user-configurable interval from 1 to 3,600 seconds
Wireless Built-in RF modem (optional): ISM license-free band Sub 1 GHz and Wi-Fi 802.11 b/g; about 100 m to RAELink3 [Z1] Mesh modem or Access Point, about 200 m to EchoView Host, RAEMesh Reader or RAEPoint
Operating temperature -20°C to 50°C (-4°F to 122°F)
Humidity 0% to 95% relative humidity (non-condensing)
Ingress protection IP-65
Safety certifications CSA: Class I, Division 1, Groups A, B, C, D, T4; Class II, Division 1, Groups E, F, G T85°C; ATEX: 0575 II 1G Ex ia IIC T4 Ga, 2G Ex ia d IIC T4 Gb with IR sensor installed, I M1 Ex ia I Ma; IECEx: Ex ia IIC T4 Ga, Ex ia d IIC T4 Gb with IR sensor installed, Ex ia I Ma; IECEx/ANZEx: Ex ia IIC T4 Ga
Performance tests MIL-STD-810G and 461F compliant; LEL CSA C22.2 No. 152, ISA-12.13.01
Languages 19 languages: Arabic, Chinese, Czech, Danish, Dutch, English, French, German, Indonesian, Italian, Japanese, Korean, Norwegian, Polish, Portuguese, Russian, Spanish, Swedish, Turkish
Model number PGM-6248
Warranty Four years on liquid O2 sensors; three years on CO and H2S sensors; two years on non-consumable components and catalytic LEL sensors; one year on all other sensors, pump, battery and consumable parts

Specifications may vary with the ordered configuration. Contact a CAD engineer for sizing to your actual operating conditions.

FAQ

Frequently asked questions about CAD-SF-402

Which kinds of threats does MultiRAE Pro detect?

Gamma radiation (0-20,000 μRem/h), VOCs with a 10.6 eV PID, combustibles (catalytic LEL, NDIR), CO2 NDIR, toxic gases and oxygen with electrochemical sensors; up to 6 threat types at a time, a two-gas combination sensor being required for a 6-threat configuration.

What battery does MultiRAE Pro use and how long does it run?

Rechargeable Li-ion about 12 hours (recharge under 6 hours), extended Li-ion about 18 hours (recharge under 9 hours), or an alkaline adapter with 4 x AA batteries about 6 hours; figures for non-wireless monitors.

What ingress protection and approvals does MultiRAE Pro have?

IP-65; ATEX 0575 II 1G Ex ia IIC T4 Ga, IECEx Ex ia IIC T4 Ga, CSA Class I Division 1 Groups A, B, C, D; MIL-STD-810G and 461F compliant.