Honeywell MultiRAE Pro Wireless Radiation and Chemical Detector
MultiRAE Pro is a Honeywell portable wireless multi-threat monitor for gamma radiation, VOCs, toxic gases, oxygen and combustibles, with over 25 swappable sensors, built-in pump, IP-65, Ex ia IIC T4 Ga.
- Brand Honeywell
- Type Portable wireless multi-threat radiation and chemical detector with built-in pump
- Sensors Over 25 intelligent interchangeable field-replaceable sensors: gamma radiation, ppb and ppm PID for VOCs, electrochemical for toxic gases and oxygen, combustible LEL and NDIR, CO2 NDIR; up to 6 threat types at a time
- Size 193 x 96.5 x 66 mm (7.6" H x 3.8" W x 2.6" D)
- Genuine products
- Full CO/CQ
- VAT invoice
- Quote within 24 working hours
PRODUCT DESCRIPTION
Honeywell MultiRAE Pro Wireless Radiation and Chemical Detector
MultiRAE Pro is a Honeywell (RAE Systems) portable wireless multi-threat monitor that detects gamma radiation and toxic industrial chemicals (TICs/TIMs), VOCs, oxygen, toxic gases and combustibles at the same time, up to 6 threat types at once. Over 25 intelligent field-swappable sensors, built-in pump, Man Down Alarm, IP-65, ATEX/IECEx Ex ia IIC T4 Ga intrinsic safety, MIL-STD-810G and 461F compliant. Model number PGM-6248.
MultiRAE Pro specifications
- Brand: Honeywell
- Type: Portable wireless multi-threat radiation and chemical detector with built-in pump
- Sensors: Over 25 intelligent interchangeable field-replaceable sensors: gamma radiation, ppb and ppm PID for VOCs, electrochemical for toxic gases and oxygen, combustible LEL and NDIR, CO2 NDIR; up to 6 threat types at a time
- Size: 193 x 96.5 x 66 mm (7.6″ H x 3.8″ W x 2.6″ D)
- Weight: 880 g (31 oz.)
- Battery: Rechargeable Li-ion (~12 hr runtime, < 6 hr recharge); extended-duration Li-ion (~18 hr runtime, < 9 hr recharge); alkaline adapter with 4 x AA batteries (~6 hr runtime). Figures for non-wireless monitors
- Display: Monochrome graphical LCD 128 x 160 with backlighting, automatic screen flip; 3 keys (Mode, Y/+, N/-)
- Sampling: Built-in pump, average flow rate 250 cc/min, auto shutoff in low-flow conditions
- Alarms: Wireless remote alarm notification; multi-tone audible (95 dB at 30 cm), vibration, flashing bright red LEDs, on-screen indication; Man Down Alarm with pre-alarm
- Datalogging: Continuous, 6 months for 5 sensors at 1-minute intervals, 24/7; user-configurable interval from 1 to 3,600 seconds
- Wireless: Built-in RF modem (optional): ISM license-free band Sub 1 GHz and Wi-Fi 802.11 b/g; about 100 m to RAELink3 [Z1] Mesh modem or Access Point, about 200 m to EchoView Host, RAEMesh Reader or RAEPoint
- Operating temperature: -20°C to 50°C (-4°F to 122°F)
- Humidity: 0% to 95% relative humidity (non-condensing)
- Ingress protection: IP-65
- Safety certifications: CSA: Class I, Division 1, Groups A, B, C, D, T4; Class II, Division 1, Groups E, F, G T85°C; ATEX: 0575 II 1G Ex ia IIC T4 Ga, 2G Ex ia d IIC T4 Gb with IR sensor installed, I M1 Ex ia I Ma; IECEx: Ex ia IIC T4 Ga, Ex ia d IIC T4 Gb with IR sensor installed, Ex ia I Ma; IECEx/ANZEx: Ex ia IIC T4 Ga
- Performance tests: MIL-STD-810G and 461F compliant; LEL CSA C22.2 No. 152, ISA-12.13.01
- Languages: 19 languages: Arabic, Chinese, Czech, Danish, Dutch, English, French, German, Indonesian, Italian, Japanese, Korean, Norwegian, Polish, Portuguese, Russian, Spanish, Swedish, Turkish
- Model number: PGM-6248
- Warranty: Four years on liquid O2 sensors; three years on CO and H2S sensors; two years on non-consumable components and catalytic LEL sensors; one year on all other sensors, pump, battery and consumable parts
Sensor ranges and resolution
| Group | Sensor | Range | Resolution |
|---|---|---|---|
| Radiation | Gamma radiation | 0-20,000 μRem/h (liều suất) | 1cc CsI (Tl) scintillator with photodiode |
| PID | VOC 10.6 eV (extended range) | 0-5,000 ppm | 0.1 ppm |
| PID | VOC 10.6 eV (ppb) | 0-2,000 ppm | 10 ppb |
| Combustible | Catalytic LEL | 0-100% LEL | 1% LEL |
| Combustible | NDIR (0-100% LEL methane) | 0-100% LEL | 1% LEL |
| Combustible | NDIR (0-100% vol. methane) | 0-100% Vol. | 0.1% Vol. |
| CO2 | Carbon dioxide (CO2) NDIR | 0-50,000 ppm | 100 ppm |
| Electrochemical | Ammonia (NH3) | 0-100 ppm | 1 ppm |
| Electrochemical | Carbon monoxide (CO) | 0-500 ppm | 1 ppm |
| Electrochemical | CO, extended range | 0-2,000 ppm | 10 ppm |
| Electrochemical | CO, H2-compensated | 0-2,000 ppm | 10 ppm |
| Electrochemical | CO + H2S combo (CO) | 0-500 ppm | 1 ppm |
| Electrochemical | CO + H2S combo (H2S) | 0-200 ppm | 0.1 ppm |
| Electrochemical | Chlorine (Cl2) | 0-50 ppm | 0.1 ppm |
| Electrochemical | Chlorine dioxide (ClO2) | 0-1 ppm | 0.03 ppm |
| Electrochemical | Ethylene oxide (ETO-A) | 0-100 ppm | 0.5 ppm |
| Electrochemical | Ethylene oxide (ETO-B) | 0-10 ppm | 0.1 ppm |
| Electrochemical | Formaldehyde (HCHO) | 0-10 ppm | 0.05 ppm |
| Electrochemical | Hydrogen cyanide (HCN) | 0-50 ppm | 0.5 ppm |
| Electrochemical | Hydrogen sulfide (H2S) | 0-100 ppm | 0.1 ppm |
| Electrochemical | Methyl mercaptan (CH3-SH) | 0-10 ppm | 0.1 ppm |
| Electrochemical | Nitric oxide (NO) | 0-250 ppm | 0.5 ppm |
| Electrochemical | Nitrogen dioxide (NO2) | 0-20 ppm | 0.1 ppm |
| Electrochemical | Oxygen (O2) | 0-30% Vol. | 0.1% Vol. |
| Electrochemical | Oxygen (LIQ O2) | 0-30% Vol. | 0.1% Vol. |
| Electrochemical | Phosphine (PH3) | 0-20 ppm | 0.1 ppm |
| Electrochemical | Phosphine (PH3 H) | 0-20 ppm | 0.1 ppm |
| Electrochemical | Sulfur dioxide (SO2) | 0-20 ppm | 0.1 ppm |
The monitor comes in wireless and non-wireless versions; order codes depend on the configuration (monitor, accessories, sampling and calibration kits, gas, sensors, replacement parts): contact CAD. A two-gas combination sensor is required for a 6-threat configuration.
Applications
The Honeywell datasheet lists civil defense (search and rescue), homeland security, HazMat response, military, semiconductor manufacturing and environmental use. The monitor works with the AutoRAE 2 automatic test and calibration system and Honeywell SafetySuite device management.
TECHNICAL SPECIFICATIONS
Specifications of Honeywell MultiRAE
| PARAMETER | VALUE |
|---|---|
| Model | MultiRAE Pro |
| Brand | Honeywell |
| Type | Portable wireless multi-threat radiation and chemical detector with built-in pump |
| Sensors | Over 25 intelligent interchangeable field-replaceable sensors: gamma radiation, ppb and ppm PID for VOCs, electrochemical for toxic gases and oxygen, combustible LEL and NDIR, CO2 NDIR; up to 6 threat types at a time |
| Size | 193 x 96.5 x 66 mm (7.6" H x 3.8" W x 2.6" D) |
| Weight | 880 g (31 oz.) |
| Battery | Rechargeable Li-ion (~12 hr runtime, < 6 hr recharge); extended-duration Li-ion (~18 hr runtime, < 9 hr recharge); alkaline adapter with 4 x AA batteries (~6 hr runtime). Figures for non-wireless monitors |
| Display | Monochrome graphical LCD 128 x 160 with backlighting, automatic screen flip; 3 keys (Mode, Y/+, N/-) |
| Sampling | Built-in pump, average flow rate 250 cc/min, auto shutoff in low-flow conditions |
| Alarms | Wireless remote alarm notification; multi-tone audible (95 dB at 30 cm), vibration, flashing bright red LEDs, on-screen indication; Man Down Alarm with pre-alarm |
| Datalogging | Continuous, 6 months for 5 sensors at 1-minute intervals, 24/7; user-configurable interval from 1 to 3,600 seconds |
| Wireless | Built-in RF modem (optional): ISM license-free band Sub 1 GHz and Wi-Fi 802.11 b/g; about 100 m to RAELink3 [Z1] Mesh modem or Access Point, about 200 m to EchoView Host, RAEMesh Reader or RAEPoint |
| Operating temperature | -20°C to 50°C (-4°F to 122°F) |
| Humidity | 0% to 95% relative humidity (non-condensing) |
| Ingress protection | IP-65 |
| Safety certifications | CSA: Class I, Division 1, Groups A, B, C, D, T4; Class II, Division 1, Groups E, F, G T85°C; ATEX: 0575 II 1G Ex ia IIC T4 Ga, 2G Ex ia d IIC T4 Gb with IR sensor installed, I M1 Ex ia I Ma; IECEx: Ex ia IIC T4 Ga, Ex ia d IIC T4 Gb with IR sensor installed, Ex ia I Ma; IECEx/ANZEx: Ex ia IIC T4 Ga |
| Performance tests | MIL-STD-810G and 461F compliant; LEL CSA C22.2 No. 152, ISA-12.13.01 |
| Languages | 19 languages: Arabic, Chinese, Czech, Danish, Dutch, English, French, German, Indonesian, Italian, Japanese, Korean, Norwegian, Polish, Portuguese, Russian, Spanish, Swedish, Turkish |
| Model number | PGM-6248 |
| Warranty | Four years on liquid O2 sensors; three years on CO and H2S sensors; two years on non-consumable components and catalytic LEL sensors; one year on all other sensors, pump, battery and consumable parts |
Specifications may vary with the ordered configuration. Contact a CAD engineer for sizing to your actual operating conditions.
FAQ
Frequently asked questions about CAD-SF-402
Which kinds of threats does MultiRAE Pro detect?
Gamma radiation (0-20,000 μRem/h), VOCs with a 10.6 eV PID, combustibles (catalytic LEL, NDIR), CO2 NDIR, toxic gases and oxygen with electrochemical sensors; up to 6 threat types at a time, a two-gas combination sensor being required for a 6-threat configuration.
What battery does MultiRAE Pro use and how long does it run?
Rechargeable Li-ion about 12 hours (recharge under 6 hours), extended Li-ion about 18 hours (recharge under 9 hours), or an alkaline adapter with 4 x AA batteries about 6 hours; figures for non-wireless monitors.
What ingress protection and approvals does MultiRAE Pro have?
IP-65; ATEX 0575 II 1G Ex ia IIC T4 Ga, IECEx Ex ia IIC T4 Ga, CSA Class I Division 1 Groups A, B, C, D; MIL-STD-810G and 461F compliant.