Honeywell OELD (Optima Excel Local Display) Smart Junction Box with Display
100% GENUINE
View larger
Honeywell OELD (Optima Excel Local Display) Smart Junction Box with Display

Honeywell OELD (Optima Excel Local Display) Smart Junction Box with Display

PRODUCT CODE
OELD
BRAND
Honeywell

OELD is a Honeywell smart junction box with LCD display and Bluetooth for the Searchpoint Optima Plus and Searchline Excel detectors: smartphone maintenance within 10 m, IP66, ATEX/IECEx/cULus.

  • Brand Honeywell
  • Type Smart junction box with LCD display and Bluetooth for the Searchpoint Optima Plus and Searchline Excel infrared flammable-hydrocarbon detectors
  • Display LCD showing digital readout of sensor output, bar chart, units of measurement and status icons for alarm, maintenance and active Bluetooth connection; displayed information configurable with the OELD app
  • Status indication Green / yellow / red / blue multi-colour backlight: green = normal, yellow = fault or maintenance, red = alarm; the green indication can be disabled via the app
REQUEST A QUOTE DOWNLOAD DATASHEET (PDF)
  • Genuine products
  • Full CO/CQ
  • VAT invoice
  • Quote within 24 working hours

PRODUCT DESCRIPTION

Honeywell OELD (Optima Excel Local Display) Smart Junction Box with Display

OELD (Optima Excel Local Display) is a Honeywell smart junction box with display for the Searchpoint Optima Plus and Searchline Excel infrared flammable-hydrocarbon detectors. OELD has an LCD screen for gas information, a “traffic light” status indicator visible from a distance and Bluetooth connectivity for non-intrusive maintenance from a smartphone, within 10 m. Aluminium or 316 stainless steel housing, IP66 / Type 4X, 18 to 32 Vdc supply, ATEX, IECEx and cULus certification.

How do the OELD versions differ?

The ten OELD order codes differ in housing material (aluminium or 316 stainless steel), protection type (Ex d or Ex e), cable thread (M25 or 3/4″ NPT), certification (ATEX/IECEx or cULus) and whether Bluetooth and the local interface are included or only the display. The order-code table below lists each code.

Main features

  • Maintenance with the OELD smartphone app from up to 10 m away, without opening the detector enclosure and without a hot-work permit.
  • With the app you can specify the target gas, configure alarm set points, perform one-man calibrations, access event logs, perform diagnostics and check detector status.
  • Bright indicator lights visible from a distance: green is normal, yellow is a fault or maintenance, red is an alarm; a unit in fault or warning is easier to locate.
  • The gas detector can be mounted directly or remotely to the OELD to suit the installation.

OELD specifications

  • Type: Smart junction box with LCD display and Bluetooth for the Searchpoint Optima Plus and Searchline Excel infrared flammable-hydrocarbon detectors
  • Display: LCD showing digital readout of sensor output, bar chart, units of measurement and status icons for alarm, maintenance and active Bluetooth connection; displayed information configurable with the OELD app
  • Status indication: Green / yellow / red / blue multi-colour backlight: green = normal, yellow = fault or maintenance, red = alarm; the green indication can be disabled via the app
  • Wireless interface: Bluetooth (BLE) non-intrusive connection, range up to 10 m (30 ft) depending on the mobile device, through the OELD mobile app
  • Bluetooth security: Certificate-based mutual authentication, AES128 encryption
  • Connection to the detector: Internal RS-485 connection to Searchpoint Optima Plus or Searchline Excel via SHC-1 through the SHC Protection Device
  • Supply: 18 to 32 Vdc (24 Vdc nominal), < 2 W
  • Housing material: Marine-grade aluminium alloy or 316 stainless steel with 5-coat painted finish
  • Ingress protection: IP66 / Type 4X
  • Cable entries: 5 x M25 (ATEX/IECEx version) or 5 x 3/4″ NPT (cULus version); one reserved for the sensor connection, 3 blanking plugs supplied for unused entries
  • Termination: 2 x pluggable rising-clamp type for the gas detector and field wiring, cable 0.5 to 2.5 mm2 (12 to 28 AWG)
  • Dimensions: 159 x 197 x 114 mm
  • Weight: Aluminium version 2.3 kg; stainless steel version 5.0 kg
  • Operating temperature: -40°C to +65°C (-60°C to +65°C for the CU TR-EX version only)
  • Humidity: 0 to 99 %RH, non-condensing
  • ATEX/IECEx certification: DEMKO 16 ATEX 1693X; IECEx UL 16.0066X; II 2 GD Ex db IIC T6, Ex tb IIIC T85 °C, Tamb -40 to +65 °C; EN 60079-29-1 approved accessory
  • cULus certification: Class I Div 1 A, B, C, D; Class II Div 1 F & G; Class III Div 1; Tamb -55 to +65 °C; Temp code T6; Class I Zone 1 AEx d IIC T6; Class I Zone 21 AEx tb IIIC T6; ISA 60079-29-1
  • Core approvals: EN 50270:2015 (EMC); IEC/EN/UL/CSA 61010 (electrical safety); Bluetooth Certified, RED, FCC
  • Compatibility: Backward compatible with all versions of Searchpoint Optima Plus and Searchline Excel; assessed to have no effect on the functional safety of the connected gas sensor

Order codes

Order code Description
OELDBXXXXXADMAX OELD Smart Junction Box, Display, Ex d, Aluminium, M25, ATEX/IECEx
OELDBXXXXXSDMAX OELD Smart Junction Box, Display, Ex d, 316SST, M25, ATEX/IECEx
OELDBXXXXXADNUX OELD Smart Junction Box, Display, C1D1 Z1, Aluminium, 3/4″ NPT, cULus
OELDBXXXXXSDNUX OELD Smart Junction Box, Display, C1D1 Z1, 316SST, 3/4″ NPT, cULus
OELDBXXXXXAEMAX OELD Smart Junction Box, Display, Ex e Aluminium, M25, ATEX/IECEx
OELDBXXXXXSEMAX OELD Smart Junction Box, Display, Ex e, 316SST, M25, ATEX/IECEx
OELDBXXXXXADMAL OELD Smart Junction Box, Display, Bluetooth and Local Interface, Ex d, Aluminium, M25, ATEX/IECEx | OELD ALU LUI EXD M25 ATEX
OELDBXXXXXSDMAL OELD Smart Junction Box, Display, Bluetooth and Local Interface, Ex d, 316SST, M25, ATEX/IECEx | OELD SST LUI EXD M25 ATEX
OELDBXXXXXADNUL OELD Smart Junction Box, Bluetooth and Local Interface, Display, C1D1 Z1, Aluminium, 3/4″ NPT, cULus | OELD ALU LUI C1D1Z1 NPT cULus
OELDBXXXXXSDNUL OELD Smart Junction Box, Bluetooth and Local Interface, Display, C1D1 Z1, 316SST, 3/4″ NPT, cULus | OELD SST LUI C1D1Z1 NPT cULus

Applications

The Honeywell datasheet describes use for detectors in hard-to-reach locations such as a duct: the OELD is positioned remotely in an easy-to-access location and the app is used to work with the detector wirelessly.

TECHNICAL SPECIFICATIONS

Specifications of Honeywell OELD (Optima Excel Local Display) Smart Junction Box with Display

PARAMETER VALUE
Model OELD
Brand Honeywell
Type Smart junction box with LCD display and Bluetooth for the Searchpoint Optima Plus and Searchline Excel infrared flammable-hydrocarbon detectors
Display LCD showing digital readout of sensor output, bar chart, units of measurement and status icons for alarm, maintenance and active Bluetooth connection; displayed information configurable with the OELD app
Status indication Green / yellow / red / blue multi-colour backlight: green = normal, yellow = fault or maintenance, red = alarm; the green indication can be disabled via the app
Wireless interface Bluetooth (BLE) non-intrusive connection, range up to 10 m (30 ft) depending on the mobile device, through the OELD mobile app
Bluetooth security Certificate-based mutual authentication, AES128 encryption
Connection to the detector Internal RS-485 connection to Searchpoint Optima Plus or Searchline Excel via SHC-1 through the SHC Protection Device
Supply 18 to 32 Vdc (24 Vdc nominal), < 2 W
Housing material Marine-grade aluminium alloy or 316 stainless steel with 5-coat painted finish
Ingress protection IP66 / Type 4X
Cable entries 5 x M25 (ATEX/IECEx version) or 5 x 3/4" NPT (cULus version); one reserved for the sensor connection, 3 blanking plugs supplied for unused entries
Termination 2 x pluggable rising-clamp type for the gas detector and field wiring, cable 0.5 to 2.5 mm2 (12 to 28 AWG)
Dimensions 159 x 197 x 114 mm
Weight Aluminium version 2.3 kg; stainless steel version 5.0 kg
Operating temperature -40°C to +65°C (-60°C to +65°C for the CU TR-EX version only)
Humidity 0 to 99 %RH, non-condensing
ATEX/IECEx certification DEMKO 16 ATEX 1693X; IECEx UL 16.0066X; II 2 GD Ex db IIC T6, Ex tb IIIC T85 °C, Tamb -40 to +65 °C; EN 60079-29-1 approved accessory
cULus certification Class I Div 1 A, B, C, D; Class II Div 1 F & G; Class III Div 1; Tamb -55 to +65 °C; Temp code T6; Class I Zone 1 AEx d IIC T6; Class I Zone 21 AEx tb IIIC T6; ISA 60079-29-1
Core approvals EN 50270:2015 (EMC); IEC/EN/UL/CSA 61010 (electrical safety); Bluetooth Certified, RED, FCC
Compatibility Backward compatible with all versions of Searchpoint Optima Plus and Searchline Excel; assessed to have no effect on the functional safety of the connected gas sensor

Specifications may vary with the ordered configuration. Contact a CAD engineer for sizing to your actual operating conditions.

FAQ

Frequently asked questions about OELD

Which detectors does the OELD work with?

The OELD is a smart junction box for the Searchpoint Optima Plus and Searchline Excel infrared flammable-hydrocarbon detectors and is backward compatible with all versions of both.

How does the OELD connect to a smartphone?

By Bluetooth (BLE), range up to 10 m depending on the mobile device, with the OELD app. The connection uses certificate-based mutual authentication and AES128 encryption. The app lets you specify the target gas, configure alarm set points, calibrate with one person, access event logs and run diagnostics.

What certifications and housing materials does the OELD have?

Marine-grade aluminium alloy or 316 stainless steel housing, IP66 / Type 4X. ATEX (II 2 GD Ex db IIC T6, Ex tb IIIC T85 °C), IECEx and cULus (Class I Div 1 A, B, C, D; Class I Zone 1 AEx d IIC T6) certification.

Used this product? Write a review

Your rating

20 to 1500 characters, no links.

CAD uses your name, company and text only to publish your review once approved. Your email is for CAD to check only; it is never shown or used for anything else.

Quote