Honeywell RAEGuard 2 PID Fixed Photoionisation Gas Detector
RAEGuard 2 PID is a Honeywell fixed photoionisation VOC detector, ranges from 0.01 to 1000 ppm, 4-20 mA, Modbus RS-485 and 3 relays, 316 stainless steel, ATEX/IECEx/UL/CSA.
- Brand Honeywell
- Type Fixed photoionisation detector (PID) for VOCs; pumped or diffusion models
- Measuring range (DigiPID module) 0.01 to 100 ppm, 0.1 to 1000 ppm or 1 to 1000 ppm (the 1 to 1000 ppm range has no relays or correction factors)
- Resolution 10 ppb or 1 ppm (depends on model)
- Genuine products
- Full CO/CQ
- VAT invoice
- Quote within 24 working hours
PRODUCT DESCRIPTION
Honeywell RAEGuard 2 PID Fixed Photoionisation Gas Detector
RAEGuard 2 PID is a Honeywell fixed photoionisation detector (PID) for continuous VOC monitoring in hazardous and non-hazardous locations. It comes in a pumped model (for sticky gases) and a diffusion model (for high-humidity ambients). 10 to 28 VDC supply, three-wire 4-20 mA output, RS-485 Modbus and three alarm relays; 316 stainless steel, ATEX, IECEx, UL/CSA and TR CU certification.
How to choose a RAEGuard 2 PID code
The order codes are kits of a RAEGuard 2 sensor head and a DigiPID module. They differ in measuring range (0.01 to 100 ppm, 0.1 to 1000 ppm or 1 to 1000 ppm) and regional certification (ATEX/IECEx, UL, JPEx, Russia) or the DIFF version. Note that with the 1 to 1000 ppm module the relays and correction factors cannot be used.
RAEGuard 2 PID specifications
- Type: Fixed photoionisation detector (PID) for VOCs; pumped or diffusion models
- Measuring range (DigiPID module): 0.01 to 100 ppm, 0.1 to 1000 ppm or 1 to 1000 ppm (the 1 to 1000 ppm range has no relays or correction factors)
- Resolution: 10 ppb or 1 ppm (depends on model)
- Response time (T90): < 30 s (pumped version provides improved response and recovery times on sticky gas)
- Accuracy: ±2 % at the calibration point
- Calibration: Two points (optional three-point calibration for the DigiPID module); Electronic Auto-Zero
- Correction factors: Over 200 pre-programmed correction factors to display readings of a specific target gas
- Working current / power: DC 10 to 28 V, 210 mA at 24 V, power < 5 W
- Output: 4-20 mA; three-level programmable alarm relays (30 VDC, 2 A); RS-485 (supports Modbus)
- Sampling: Internal diaphragm pump, up to 500 cc/min
- Display: 128 x 64 matrix backlit graphic LCD; LED status indicator; three-key magnetic bar adjustment
- Ingress protection: IP65
- Mechanical interface / installation: 3/4 in NPT male; 50.8 mm (2 in) pipe-holding or wall mounting
- Material: 316 stainless steel
- Sensor head size / weight: 257 x 201 x 107 mm; 3.5 kg
- Temperature / humidity / pressure: -20°C to +55°C; 0 to 95 % relative humidity, non-condensing; 90 to 110 kPa
- Warranty: Pump 1 year, housing and electronics 2 years; DigiPID module: lamp 2 years, sensor, electronics and housing 1 year
- Certification (sensor head): ATEX: Ex II 2(1)G, Ex d [ia Ga] IIC T4 Gb; IECEx: Ex d [ia Ga] IIC T4 Gb; UL/CSA: Class 1, Div. 1, Groups A B C D T4; TR CU: 1Ex d [ia Ga] IIC T4 Gb X
- Certification (DigiPID module): ATEX: II 1 G Ex ia IIC T4 and I M1 Ex ia I; IECEx: Ex ia IIC T4 Ga and Ex ia I; UL/CSA: Class I, Div. 1, Groups A B C D T4; TR CU: 0Ex ia IIC T4 Ga X
- Kit includes: RAEGuard 2 fixed sensor head (explosion-proof stainless steel enclosure with LCD, integrated sampling pump, relays, magnetic key) + DigiPID sensor module with UV lamp + DigiPID maintenance kit
Order codes
| Order code | Description |
|---|---|
| H-D03-0001-000 | Kit, RAEGuard 2 PID, DIFF, 0.01 – 100 ppm, FGM-2001 |
| H-D03-0001-JP0 | Kit, RAEGuard 2 PID, DIFF, JPEx, 0.01 – 100 ppm, FGM-2001 |
| H-D03-0002-000 | Kit, RAEGuard 2 PID, DIFF, 0.1 – 1000 ppm, FGM-2002 |
| H-D03-0002-JP0 | Kit, RAEGuard 2 PID, DIFF, JPEx, 0.1 – 1000 ppm, FGM-2002 |
| H-D03-0015-000 | Kit, RAEGuard 2 PID, DIFF, 0.01 – 100 ppm, FGM-2001, UL |
| H-D03-0016-000 | Kit, RAEGuard 2 PID, DIFF, 0.1 – 1000 ppm, FGM-2002, UL |
| H-D03-0004-000 | Kit, RAEGuard 2 PID, ATEX/IECEx, 0.01 – 100 ppm isobutylene equivalent |
| H-D03-0004-R00 | Kit, RAEGuard 2 PID, Russia, 0.01 – 100 ppm isobutylene equivalent |
| H-D03-0004-JP0 | Kit, RAEGuard 2 PID, JPEx, 0.01 – 100 ppm isobutylene equivalent |
| H-D03-0009-000 | Kit, RAEGuard 2 PID, UL, 0.01 – 100 ppm isobutylene equivalent |
| H-D03-0005-000 | Kit, RAEGuard 2 PID, ATEX/IECEx, 0.1 – 1000 ppm isobutylene equivalent |
| H-D03-0005-R00 | Kit, RAEGuard 2 PID, Russia, 0.1 – 1000 ppm isobutylene equivalent |
| H-D03-0005-JP0 | Kit, RAEGuard 2 PID, JPEx, 0.1 – 1000 ppm isobutylene equivalent |
| H-D03-0010-000 | Kit, RAEGuard 2 PID, UL, 0.1 – 1000 ppm isobutylene equivalent |
| H-D03-0008-000 | Kit, RAEGuard 2 PID, ATEX/IECEx, 1 – 1000 ppm isobutylene equivalent |
| H-D03-0008-R00 | Kit, RAEGuard 2 PID, Russia, 1 – 1000 ppm isobutylene equivalent |
| H-D03-0008-JP0 | Kit, RAEGuard 2 PID, JPEx, 1 – 1000 ppm isobutylene equivalent |
| H-D03-0012-000 | Kit, RAEGuard 2 PID, UL, 1 – 1000 ppm isobutylene equivalent |
Applications
The Honeywell datasheet lists these key applications and their VOCs: benzene in refinery analyser shelters, ammonia in industry, vinyl chloride in chemical manufacturing, toluene or ammonia in semiconductor plants, solvent and chemicals storage, phenol and DME in pharmaceutical, toluene in printing, air quality, methyl ethyl ketone in paint spray booths, heat transfer fluids, and acetone, xylene and phenol in medical, pathology and histology labs.
TECHNICAL SPECIFICATIONS
Specifications of Honeywell RAEGuard 2 PID Fixed Photoionisation Gas Detector
| PARAMETER | VALUE |
|---|---|
| Model | RAEGuard 2 PID |
| Brand | Honeywell |
| Type | Fixed photoionisation detector (PID) for VOCs; pumped or diffusion models |
| Measuring range (DigiPID module) | 0.01 to 100 ppm, 0.1 to 1000 ppm or 1 to 1000 ppm (the 1 to 1000 ppm range has no relays or correction factors) |
| Resolution | 10 ppb or 1 ppm (depends on model) |
| Response time (T90) | < 30 s (pumped version provides improved response and recovery times on sticky gas) |
| Accuracy | ±2 % at the calibration point |
| Calibration | Two points (optional three-point calibration for the DigiPID module); Electronic Auto-Zero |
| Correction factors | Over 200 pre-programmed correction factors to display readings of a specific target gas |
| Working current / power | DC 10 to 28 V, 210 mA at 24 V, power < 5 W |
| Output | 4-20 mA; three-level programmable alarm relays (30 VDC, 2 A); RS-485 (supports Modbus) |
| Sampling | Internal diaphragm pump, up to 500 cc/min |
| Display | 128 x 64 matrix backlit graphic LCD; LED status indicator; three-key magnetic bar adjustment |
| Ingress protection | IP65 |
| Mechanical interface / installation | 3/4 in NPT male; 50.8 mm (2 in) pipe-holding or wall mounting |
| Material | 316 stainless steel |
| Sensor head size / weight | 257 x 201 x 107 mm; 3.5 kg |
| Temperature / humidity / pressure | -20°C to +55°C; 0 to 95 % relative humidity, non-condensing; 90 to 110 kPa |
| Warranty | Pump 1 year, housing and electronics 2 years; DigiPID module: lamp 2 years, sensor, electronics and housing 1 year |
| Certification (sensor head) | ATEX: Ex II 2(1)G, Ex d [ia Ga] IIC T4 Gb; IECEx: Ex d [ia Ga] IIC T4 Gb; UL/CSA: Class 1, Div. 1, Groups A B C D T4; TR CU: 1Ex d [ia Ga] IIC T4 Gb X |
| Certification (DigiPID module) | ATEX: II 1 G Ex ia IIC T4 and I M1 Ex ia I; IECEx: Ex ia IIC T4 Ga and Ex ia I; UL/CSA: Class I, Div. 1, Groups A B C D T4; TR CU: 0Ex ia IIC T4 Ga X |
| Kit includes | RAEGuard 2 fixed sensor head (explosion-proof stainless steel enclosure with LCD, integrated sampling pump, relays, magnetic key) + DigiPID sensor module with UV lamp + DigiPID maintenance kit |
Specifications may vary with the ordered configuration. Contact a CAD engineer for sizing to your actual operating conditions.
FAQ
Frequently asked questions about RAEGuard 2 PID
What gas and range does the RAEGuard 2 PID measure?
It measures VOCs with the DigiPID photoionisation sensor, range 0.01 to 100 ppm, 0.1 to 1000 ppm or 1 to 1000 ppm depending on the code; over 200 correction factors are pre-programmed to display a specific target gas (not available with the 1 to 1000 ppm module).
How do the pumped and diffusion RAEGuard 2 PID models differ?
The datasheet states the pumped model is used for sticky gas and the diffusion model for high-humidity ambients. The internal diaphragm pump samples up to 500 cc/min.
What outputs and certifications does the RAEGuard 2 PID have?
4-20 mA, RS-485 Modbus and three alarm relays (30 VDC, 2 A); IP65. The sensor head is certified ATEX Ex II 2(1)G Ex d [ia Ga] IIC T4 Gb, IECEx, UL/CSA Class 1 Div. 1 Groups A B C D T4 and TR CU.