Searchline Excel is a Honeywell infrared open path flammable gas detector, 5 to 200 m path, T90 under 3 seconds, 4-20 mA and Modbus outputs, 316 stainless steel, IP66/IP67, ATEX/IECEx/UL/CSA/FM.

  • Brand Honeywell
  • Type Infrared open path (line-of-sight) flammable gas detection system with transmitter (Tx) and receiver (Rx)
  • Available gases Methane, ethane, propane, butane, pentane, ethylene, propylene, butadiene
  • Range 0 to 5 LEL.m
REQUEST A QUOTE DOWNLOAD DATASHEET (PDF)
  • Genuine products
  • Full CO/CQ
  • VAT invoice
  • Quote within 24 working hours

PRODUCT DESCRIPTION

Honeywell Searchline Excel Infrared Open Path Gas Detector

Searchline Excel is a Honeywell infrared open path flammable gas detection system with a transmitter (Tx) and a receiver (Rx) facing each other over 5 to 200 m. It detects methane, ethane, propane, butane, pentane, ethylene, propylene and butadiene, range 0 to 5 LEL.m, T90 under 3 seconds, 4-20 mA (source or sink) and Modbus RS485 outputs. 316 stainless steel, IP66 and IP67, ATEX, IECEx, UL, CSA, FM approvals and an IEC 61508 assessment.

How to choose a Searchline Excel code

The codes differ in path length (short 5 to 40 m, medium 40 to 120 m, long 120 to 200 m), certification (ATEX/IECEx, UL, CSA, Inmetro, CU-TR Ex, or ATEX/IECEx/DNV for marine) and output type (current source or sink). The full ATEX/IECEx codes include Tx, Rx and 2 Ex e junction boxes; the marine version 02104-N-NSNM does not include the XNX and junction boxes, which are ordered separately.

Technical features

  • Double band pass filter that fully compensates for all types of fog and rain.
  • Fully immune to sunlight and other radiation sources such as flare stacks, arc welding and lightning (xenon flash lamp, modulated signal).
  • Coaxial optics and heated windows; correct operation under partial obscuration.
  • True Alignment system with a telescope sight; optional Modbus RS485 multi drop output.

Searchline Excel specifications

  • Type: Infrared open path (line-of-sight) flammable gas detection system with transmitter (Tx) and receiver (Rx)
  • Available gases: Methane, ethane, propane, butane, pentane, ethylene, propylene, butadiene
  • Range: 0 to 5 LEL.m
  • Recommended alarm settings: (Low) 1.0 LEL.m; (high) 3.0 LEL.m
  • Path lengths: Short range 5 to 40 m (15 to 130 ft); medium range 40 to 120 m (130 to 390 ft); long range 120 to 200 m (390 to 650 ft)
  • Speed of response: T90 less than 3 seconds (under normal operating conditions)
  • Output signal: 4-20 mA (maximum loop resistance 600 ohms; source and sink available) and RS485; 21 mA over range; 4-20 mA normal operation (0 to 5 LEL.m); 3 mA dirty optics; 2.5 mA beam blocked; 2 mA, 0 mA fault (user programmable)
  • Digital output: Modbus RS485 multi drop, using DX100 (M) or XNX Universal Transmitter with Modbus option (up to 32 detectors on one comms cable)
  • Operating temperature: -40°C to +65°C
  • Humidity / pressure: 0 to 99 % RH (non-condensing); 91.5 to 105.5 kPa (non-compensated)
  • Warm-up time: Less than 5 minutes (operational), or less than 1 hour (fully stabilised)
  • Power supply: 18 to 32 VDC
  • Power consumption: Short range Tx: 3.5 W / 5.0 W* maximum; medium and long range Tx: 10 W / 13 W* maximum; Rx: 8 W maximum. * Turboheating activated (standard feature, user selectable; recommended for the most severe weather conditions)
  • Enclosure material: 316 stainless steel
  • Weight (inc. mounting bracket): Short range Tx: 3.5 kg; medium and long range Tx: 7 kg; Rx: 3.5 kg
  • Ingress protection: IP66 and IP67
  • Vibration: 2 to 60 Hz, max peak-to-peak amplitude 1 mm
  • Misalignment tolerance: Short range ±0.5° (±35 cm at 40 m); medium range ±0.5° (±104 cm at 120 m); long range ±0.5° (±170 cm at 200 m)
  • Safety approval: ATEX Tx: II 2 G Ex d op is IIC T5 (Tamb -40°C to +65°C) Gb and T6 (Tamb -40°C to +40°C) Gb; Rx: II 2 G Ex d IIC T5 / T6 Gb. IECEx equivalent. UL: Class 1 Groups B, C, D, Zone 1 AEx d IIB + Hydrogen; CSA: Class 1 Div 1 groups B, C, D, T5 and Exd IIC T5; FM: Class 1 Div 1 groups B, C, D & T5; GOST
  • Performance approval / EMC: FM performance approved; independently assessed to IEC 61508; EMC EN 50270
  • Accessories: Deluge shield / sunshade, True Alignment system, gassing cell, hand-held interrogator, optical gas test filters, SHC protection device

Order codes

Path lengths follow the datasheet; some rows of CAD’s list give a different range and have been corrected to 40 to 120 m (medium) and 120 to 200 m (long) to match the datasheet.

Short range (5 to 40 m)

Order code Description
02104-N-4014 Excel line-of-sight gas detection system, short range (5 to 40 m), 4 to 20mA (source) and Modbus outputs, ATEX/IECEx, fully wired with flexible conduit, electro polished 316SS. Includes Tx, Rx, 2 x Ex e Junction boxes with M20/M25 cable entries, 316SS mounting plates, brackets and hardware
02104-N-4044 Excel line-of-sight gas detection system, short range (5 to 40 m), 4 to 20mA (sink) and Modbus outputs, ATEX/IECEx, fully wired with flexible conduit, electro polished 316SS. Includes Tx, Rx, 2 x Ex e Junction boxes with M20/M25 cable entries, 316SS mounting plates, brackets and hardware
02104-N-5012 Short range system 5m to 40m UL complete IR Source and Receiver system, fully wired with flexible conduit, SS316 mounting plates, brackets, Junction Box, Current Source
02104-N-5042 Short range system 5m to 40m UL complete IR Source and Receiver system, fully wired with flexible conduit, SS316 mounting plates, brackets, Junction Box, Current Sink
02104-N-6012 Short range system 5m to 40m CSA complete IR Source and Receiver system, fully wired with flexible conduit, SS316 mounting plates, brackets, Junction Box, Current Source
02104-N-6042 Short range system 5m to 40m CSA complete IR Source and Receiver system, fully wired with flexible conduit, SS316 mounting plates, brackets, Junction Box, Current Sink
02104-N-7012 Short range system 5m to 40m Inmetro complete TXR and RXR system, fully wired with flexible conduit, SS316 mounting plates, brackets, Junction Box, Current Source
02104-N-7042 Short range system 5m to 40m Inmetro complete TXR and RXR system, fully wired with flexible conduit, SS316 mounting plates, brackets, Junction Box, Current Sink
02104-N-NSNM Excel line-of-sight gas detection system. Short range (5 to 40 m), 4 to 20mA output, ATEX/IECEx, DNV, fully wired with flexible conduit, electro polished 316SS. Includes Tx, Rx, 316SS maritime mounting plates, brackets and hardware. Order XNX and Junction boxes to be separately.
02104-N-4814 Excel line-of-sight gas detection system, short range (5 to 40 m), 4 to 20mA (source) and Modbus outputs, CU-TR Ex, fully wired with flexible conduit, electro polished 316SS. Includes Tx, Rx, 316SS mounting plates, brackets and hardware
02104-N-4844 Excel line-of-sight gas detection system, short range (5 to 40 m), 4 to 20mA (sink) and Modbus outputs, CU-TR Ex, fully wired with flexible conduit, electro polished 316SS. Includes Tx, Rx, 316SS mounting plates, brackets and hardware

Medium range (40 to 120 m)

Order code Description
02104-N-4024 Excel line-of-sight gas detection system, medium range (40 to 120 m), 4 to 20mA (source) and Modbus outputs, ATEX/IECEx, fully wired with flexible conduit, electro polished 316SS. Includes Tx, Rx, 2 x Ex e junction boxes with M20/M25 cable entries, 316SS mounting plates, brackets and hardware
02104-N-4054 Excel line-of-sight gas detection system, medium range (40 to 120 m), 4 to 20mA (sink) and Modbus outputs, ATEX/IECEx, fully wired with flexible conduit, electro polished 316SS. Includes Tx, Rx, 2 x Ex e junction boxes with M20/M25 cable entries, 316SS mounting plates, brackets and hardware
02104-N-5022 Medium range system 40m to 120m UL complete IR Source and Receiver system, fully wired with flexible conduit, SS316 mounting plates and brackets, Junction Box. Current Source
02104-N-5052 Medium range system 40m to 120m UL complete IR Source and Receiver system, fully wired with flexible conduit, SS316 mounting plates and brackets, Junction Box. Current Sink
02104-N-6022 Medium range system 40m to 120m CSA complete IR Source and Receiver system, fully wired with flexible conduit, SS316 mounting plates and brackets, Junction Box. Current Source
02104-N-6052 Medium range system 40m to 120m CSA complete IR Source and Receiver system, fully wired with flexible conduit, SS316 mounting plates and brackets, Junction Box. Current Sink
02104-N-7022 Medium range system 40m to 120m Inmetro complete TXR and RXR system, fully wired with flexible conduit, SS316 mounting plates and brackets, Junction Box. Current Source
02104-N-7052 Medium range system 40m to 120m Inmetro complete TXR and RXR system, fully wired with flexible conduit, SS316 mounting plates and brackets, Junction Box. Current Sink
02104-N-4824 Excel line-of-sight gas detection system, medium range (40 to 120 m), 4 to 20mA (source) and Modbus outputs, CU-TR Ex, fully wired with flexible conduit, electro polished 316SS. Includes Tx, Rx, 316SS mounting plates, brackets and hardware
02104-N-4854 Excel line-of-sight gas detection system, medium range (40 to 120 m), 4 to 20mA (sink) and Modbus outputs, CU-TR Ex, fully wired with flexible conduit, electro polished 316SS. Includes Tx, Rx, 316SS mounting plates, brackets and hardware

Long range (120 to 200 m)

Order code Description
02104-N-4034 Excel line-of-sight gas detection system, long range (120 to 200 m), 4 to 20mA (source) and Modbus outputs, ATEX/IECEx, fully wired with flexible conduit, electro polished 316SS. Includes Tx, Rx, 2 x Ex e junction boxes with M20/M25 cable entries, 316SS mounting plates, brackets and hardware
02104-N-4064 Excel line-of-sight gas detection system, long range (120 to 200 m), 4 to 20mA (sink) and Modbus outputs, ATEX/IECEx, fully wired with flexible conduit, electro polished 316SS. Includes Tx, Rx, 2 x Ex e junction boxes with M20/M25 cable entries, 316SS mounting plates, brackets and hardware
02104-N-5032 Long range system 120m to 200m UL complete IR Source and Receiver system, fully wired with flexible conduit, SS316 mounting plates and brackets, Junction Box. Current Source
02104-N-5062 Long range system 120m to 200m UL complete IR Source and Receiver system, fully wired with flexible conduit, SS316 mounting plates and brackets, Junction Box. Current Sink
02104-N-6032 Long range system 120m to 200m CSA complete IR Source and Receiver system, fully wired with flexible conduit, SS316 mounting plates and brackets, Junction Box. Current Source
02104-N-6062 Long range system 120m to 200m CSA complete IR Source and Receiver system, fully wired with flexible conduit, SS316 mounting plates and brackets, Junction Box. Current Sink
02104-N-7032 Long range system 120m to 200m Inmetro complete TXR and RXR system, fully wired with flexible conduit, SS316 mounting plates and brackets, Junction Box. Current Source
02104-N-7062 Long range system 120m to 200m Inmetro complete TXR and RXR system, fully wired with flexible conduit, SS316 mounting plates and brackets, Junction Box. Current Sink
02104-N-4834 Excel line-of-sight gas detection system, long range (120 to 200 m), 4 to 20mA (source) and Modbus outputs, CU-TR Ex, fully wired with flexible conduit, electro polished 316SS. Includes Tx, Rx, 316SS mounting plates, brackets and hardware
02104-N-4864 Excel line-of-sight gas detection system, long range (120 to 200 m), 4 to 20mA (sink) and Modbus outputs, CU-TR Ex, fully wired with flexible conduit, electro polished 316SS. Includes Tx, Rx, 316SS mounting plates, brackets and hardware

Applications

The Honeywell datasheet lists these applications: offshore platforms and vessels (FPSOs), downstream chemical processing plants, gas transport and pipelines, large storage areas and buildings, perimeter detection.

TECHNICAL SPECIFICATIONS

Specifications of Honeywell Searchline Excel Infrared Open Path Gas Detector

PARAMETER VALUE
Model Searchline Excel
Brand Honeywell
Type Infrared open path (line-of-sight) flammable gas detection system with transmitter (Tx) and receiver (Rx)
Available gases Methane, ethane, propane, butane, pentane, ethylene, propylene, butadiene
Range 0 to 5 LEL.m
Recommended alarm settings (Low) 1.0 LEL.m; (high) 3.0 LEL.m
Path lengths Short range 5 to 40 m (15 to 130 ft); medium range 40 to 120 m (130 to 390 ft); long range 120 to 200 m (390 to 650 ft)
Speed of response T90 less than 3 seconds (under normal operating conditions)
Output signal 4-20 mA (maximum loop resistance 600 ohms; source and sink available) and RS485; 21 mA over range; 4-20 mA normal operation (0 to 5 LEL.m); 3 mA dirty optics; 2.5 mA beam blocked; 2 mA, 0 mA fault (user programmable)
Digital output Modbus RS485 multi drop, using DX100 (M) or XNX Universal Transmitter with Modbus option (up to 32 detectors on one comms cable)
Operating temperature -40°C to +65°C
Humidity / pressure 0 to 99 % RH (non-condensing); 91.5 to 105.5 kPa (non-compensated)
Warm-up time Less than 5 minutes (operational), or less than 1 hour (fully stabilised)
Power supply 18 to 32 VDC
Power consumption Short range Tx: 3.5 W / 5.0 W* maximum; medium and long range Tx: 10 W / 13 W* maximum; Rx: 8 W maximum. * Turboheating activated (standard feature, user selectable; recommended for the most severe weather conditions)
Enclosure material 316 stainless steel
Weight (inc. mounting bracket) Short range Tx: 3.5 kg; medium and long range Tx: 7 kg; Rx: 3.5 kg
Ingress protection IP66 and IP67
Vibration 2 to 60 Hz, max peak-to-peak amplitude 1 mm
Misalignment tolerance Short range ±0.5° (±35 cm at 40 m); medium range ±0.5° (±104 cm at 120 m); long range ±0.5° (±170 cm at 200 m)
Safety approval ATEX Tx: II 2 G Ex d op is IIC T5 (Tamb -40°C to +65°C) Gb and T6 (Tamb -40°C to +40°C) Gb; Rx: II 2 G Ex d IIC T5 / T6 Gb. IECEx equivalent. UL: Class 1 Groups B, C, D, Zone 1 AEx d IIB + Hydrogen; CSA: Class 1 Div 1 groups B, C, D, T5 and Exd IIC T5; FM: Class 1 Div 1 groups B, C, D & T5; GOST
Performance approval / EMC FM performance approved; independently assessed to IEC 61508; EMC EN 50270
Accessories Deluge shield / sunshade, True Alignment system, gassing cell, hand-held interrogator, optical gas test filters, SHC protection device

Specifications may vary with the ordered configuration. Contact a CAD engineer for sizing to your actual operating conditions.

FAQ

Frequently asked questions about Searchline Excel

What path lengths does the Searchline Excel cover?

Three: short 5 to 40 m, medium 40 to 120 m and long 120 to 200 m. Range 0 to 5 LEL.m; recommended alarm settings are low 1.0 LEL.m and high 3.0 LEL.m.

Which gases does the Searchline Excel detect and how fast does it respond?

Methane, ethane, propane, butane, pentane, ethylene, propylene and butadiene; T90 response under 3 seconds under normal operating conditions.

How does the Searchline Excel connect to a control system?

4-20 mA output (source or sink) and multi drop RS485 Modbus using a DX100 (M) or an XNX Universal Transmitter with the Modbus option; one comms cable can serve up to 32 detectors.