Honeywell Sensepoint XRL Fixed Gas Detector
100% GENUINE
View larger
Honeywell Sensepoint XRL Fixed Gas Detector

Honeywell Sensepoint XRL Fixed Gas Detector

PRODUCT CODE
Sensepoint XRL
BRAND
Honeywell

Sensepoint XRL is a Honeywell fixed gas detector for flammable, toxic and oxygen gases, mA or Modbus RTU output, smartphone setup and calibration over Bluetooth, IP66, ATEX/IECEx/cULus.

  • Brand Honeywell
  • Type Fixed point gas detector for flammable, toxic and oxygen gases; configuration, calibration and bump tests from a smartphone over Bluetooth
  • Gases per datasheet Combustible 0-100 %LEL (adjustable 20-100 %LEL, factory calibrated to methane); O2 0-25 %vol; CO 0-300 ppm (adjustable 50-1000 ppm); H2 0-1000 ppm; H2S low range 0-50 ppm (adjustable 10-50 ppm); H2S high range 0-100 ppm (adjustable 50-200 ppm)
  • Output Analog 0 to 22 mA (selectable source or sink) or Modbus RTU
REQUEST A QUOTE DOWNLOAD DATASHEET (PDF)
  • Genuine products
  • Full CO/CQ
  • VAT invoice
  • Quote within 24 working hours

PRODUCT DESCRIPTION

Honeywell Sensepoint XRL Fixed Gas Detector

Sensepoint XRL is a Honeywell fixed point gas detector for flammable, toxic and oxygen gases, with an analog mA output (selectable source or sink) or Modbus RTU. The detector pairs with a smartphone over Bluetooth for configuration, calibration, bump tests and unit history without opening the enclosure. Aluminium casing, IP66 / NEMA 4X, operating temperature -40 to 65 °C, ATEX, IECEx and cULus certification.

How to choose a Sensepoint XRL code

The codes below differ in gas and range, certification (ATEX or cULus; the Cl2 versions are the Rugged Safe Area type) and output (mA or Modbus). The Honeywell datasheet (08/2017) lists flammable, O2, CO, H2 and H2S sensors; the NO2, SO2 and Cl2 codes in the table come from CAD’s part-number list.

Sensepoint XRL specifications

  • Type: Fixed point gas detector for flammable, toxic and oxygen gases; configuration, calibration and bump tests from a smartphone over Bluetooth
  • Gases per datasheet: Combustible 0-100 %LEL (adjustable 20-100 %LEL, factory calibrated to methane); O2 0-25 %vol; CO 0-300 ppm (adjustable 50-1000 ppm); H2 0-1000 ppm; H2S low range 0-50 ppm (adjustable 10-50 ppm); H2S high range 0-100 ppm (adjustable 50-200 ppm)
  • Output: Analog 0 to 22 mA (selectable source or sink) or Modbus RTU
  • Power supply: 24 V DC (mA versions: 11 to 32 VDC, Modbus versions: 9 to 32 VDC) or 24 V AC (20 to 27 VAC), 50/60 Hz; inrush current 850 mA
  • Maximum power consumption: mA versions: < 1.5 W (toxic), < 2.6 W (flammable); Modbus versions: < 1.0 W (toxic), < 2.0 W (flammable)
  • Visual indicator: Multi-colour LED light ring: flashing green = normal, flashing red = alarm, flashing green and yellow = warning, flashing yellow = fault, solid yellow = inhibited, blue = Bluetooth pairing / connected
  • Wireless interface: Bluetooth 4.0 (Bluetooth Low Energy), dedicated mobile app, connection up to 10 m (30 ft); Android 4.3 or above
  • Casing material: Aluminum alloy LM20 (charcoal or yellow)
  • Ingress protection: IP66, NEMA 4X
  • Dimensions: 118 x 159 x 93 mm
  • Weight: 1400 g
  • Lifetime: 10 years (excludes sensor)
  • Operating temperature: -40 to 65 °C
  • Storage temperature: 0 to 30 °C
  • Humidity / pressure: 0 to 99 % (non-condensing); 90 to 110 kPa
  • Connection: Pluggable rising clamp style, 0.5 to 2.5 mm2 (20 to 13 AWG)
  • Hazardous area certification: ATEX: II 2 GD, Ex db IIC T6 Gb, Ex tb IIIC T85 °C Db, Tamb -40 to +65 °C. IECEx: Ex db IIC T6 Gb, Ex tb IIIC T85 °C Db. cULus: Class I Div 1 & 2 Groups B, C, D; Class II Div 1 & 2 Groups E, F, G; Class I Zone 1 AEx db IIC T6; Zone 21 AEx tb IIIC T85 °C, IP6X
  • Other standards: Electrical safety EN/IEC/UL 61010-1, CSA C22.2 No. 61010-1-12; EMC EN 50270:2015; radio RED, FCC, IC; gas performance CSA C22.2 No. 152-M1984, UL 2075, AS 1668.2
  • Accessories: Calibration cap, collecting cone, pole mount bracket kit, duct mount kit, weather protection, flow housing
  • Compatible system controller: Touchpoint Plus

Order codes

ATEX, mA output

Order code Description
SPLIO1BAXYMAZZ Sensepoint XRL BT, ATEX, gas O2 25.0%VOL, mA output, YEL (yellow)
SPLIC1BAXYMAZZ Sensepoint XRL BT, ATEX, gas CO 300ppm, mA output, YEL (yellow)
SPLIH1BAXYMAZZ Sensepoint XRL BT, ATEX, gas H2S 50ppm, mA output, YEL (yellow)
SPLIH2BAXYMAZZ Sensepoint XRL BT, ATEX, gas H2S 100ppm, mA output, YEL (yellow)
SPLIG1BAXYMAZZ Sensepoint XRL BT, ATEX, gas H2 1000ppm, mA output, YEL (yellow)
SPLIF6BAXYMAZZ Sensepoint XRL BT, ATEX, gas CH4 100%LEL, mA output, YEL (yellow)
SPLIN1BAXYMAZZ Sensepoint XRL BT, ATEX, gas NO2 20ppm, mA output, YEL (yellow)
SPLIS1BAXYMAZZ Sensepoint XRL BT, ATEX, gas SO2 50ppm, mA output, YEL (yellow)

ATEX, Modbus output

Order code Description
SPLIO1BMXYMAZZ Sensepoint XRL BT, ATEX, gas O2 25.0%VOL, Modbus output, YEL (yellow)
SPLIC1BMXYMAZZ Sensepoint XRL BT, ATEX, gas CO 300ppm, Modbus output, YEL (yellow)
SPLIH1BMXYMAZZ Sensepoint XRL BT, ATEX, gas H2S 50ppm, Modbus output, YEL (yellow)
SPLIH2BMXYMAZZ Sensepoint XRL BT, ATEX, gas H2S 100ppm, Modbus output, YEL (yellow)
SPLIG1BMXYMAZZ Sensepoint XRL BT, ATEX, gas H2 1000ppm, Modbus output, YEL (yellow)
SPLIF6BMXYMAZZ Sensepoint XRL BT, ATEX, gas CH4 100%LEL, Modbus output, YEL (yellow)
SPLIN1BMXYMAZZ Sensepoint XRL BT, ATEX, gas NO2 20ppm, Modbus output, YEL (yellow)
SPLIS1BMXYMAZZ Sensepoint XRL BT, ATEX, gas SO2 50ppm, Modbus output, YEL (yellow)

cULus, mA output

Order code Description
SPLIO1BAXYNUZZ Sensepoint XRL BT, cULus, gas O2 25.0%VOL, mA output, YEL (yellow)
SPLIC1BAXYNUZZ Sensepoint XRL BT, cULus, gas CO 300ppm, mA output, YEL (yellow)
SPLIH1BAXYNUZZ Sensepoint XRL BT, cULus, gas H2S 50ppm, mA output, YEL (yellow)
SPLIH2BAXYNUZZ Sensepoint XRL BT, cULus, gas H2S 100ppm, mA output, YEL (yellow)
SPLIG1BAXYNUZZ Sensepoint XRL BT, cULus, gas H2 1000ppm, mA output, YEL (yellow)
SPLIF6BAXYNUZZ Sensepoint XRL BT, cULus, gas CH4 100%LEL, mA output, YEL (yellow)
SPLIN1BAXYNUZZ Sensepoint XRL BT, cULus, gas NO2 20ppm, mA output, YEL (yellow)
SPLIS1BAXYNUZZ Sensepoint XRL BT, cULus, gas SO2 50ppm, mA output, YEL (yellow)

cULus, Modbus output

Order code Description
SPLIO1BMXYNUZZ Sensepoint XRL BT, cULus, gas O2 25.0%VOL, Modbus output, YEL (yellow)
SPLIC1BMXYNUZZ Sensepoint XRL BT, cULus, gas CO 300ppm, Modbus output, YEL (yellow)
SPLIH1BMXYNUZZ Sensepoint XRL BT, cULus, gas H2S 50ppm, Modbus output, YEL (yellow)
SPLIH2BMXYNUZZ Sensepoint XRL BT, cULus, gas H2S 100ppm, Modbus output, YEL (yellow)
SPLIG1BMXYNUZZ Sensepoint XRL BT, cULus, gas H2 1000ppm, Modbus output, YEL (yellow)
SPLIF6BMXYNUZZ Sensepoint XRL BT, cULus, gas CH4 100%LEL, Modbus output, YEL (yellow)
SPLIN1BMXYNUZZ Sensepoint XRL BT, cULus, gas NO2 20ppm, Modbus output, YEL (yellow)
SPLIS1BMXYNUZZ Sensepoint XRL BT, cULus, gas SO2 50ppm, Modbus output, YEL (yellow)

Rugged Safe Area, mA output

Order code Description
SPLRL1BAXYNNZZ Sensepoint XRL BT, Rugged Safe Area, gas Cl2 5ppm, mA output, YEL (yellow), 3/4″ NPT
SPLRL1BAXYMNZZ Sensepoint XRL BT, Rugged Safe Area, gas Cl2 5ppm, mA output, YEL (yellow), M20

Rugged Safe Area, Modbus output

Order code Description
SPLRL1BMXYNNZZ Sensepoint XRL BT, Rugged Safe Area, gas Cl2 5ppm, Modbus output, YEL (yellow), 3/4″ NPT
SPLRL1BMXYMNZZ Sensepoint XRL BT, Rugged Safe Area, gas Cl2 5ppm, Modbus output, YEL (yellow), M20

Applications

The Honeywell datasheet lists these typical applications: manufacturing facilities and factories, water treatment plants, battery charging facilities, vehicle test facilities, petrochemical plants, fuelling depots.

TECHNICAL SPECIFICATIONS

Specifications of Honeywell Sensepoint XRL Fixed Gas Detector

PARAMETER VALUE
Model Sensepoint XRL
Brand Honeywell
Type Fixed point gas detector for flammable, toxic and oxygen gases; configuration, calibration and bump tests from a smartphone over Bluetooth
Gases per datasheet Combustible 0-100 %LEL (adjustable 20-100 %LEL, factory calibrated to methane); O2 0-25 %vol; CO 0-300 ppm (adjustable 50-1000 ppm); H2 0-1000 ppm; H2S low range 0-50 ppm (adjustable 10-50 ppm); H2S high range 0-100 ppm (adjustable 50-200 ppm)
Output Analog 0 to 22 mA (selectable source or sink) or Modbus RTU
Power supply 24 V DC (mA versions: 11 to 32 VDC, Modbus versions: 9 to 32 VDC) or 24 V AC (20 to 27 VAC), 50/60 Hz; inrush current 850 mA
Maximum power consumption mA versions: < 1.5 W (toxic), < 2.6 W (flammable); Modbus versions: < 1.0 W (toxic), < 2.0 W (flammable)
Visual indicator Multi-colour LED light ring: flashing green = normal, flashing red = alarm, flashing green and yellow = warning, flashing yellow = fault, solid yellow = inhibited, blue = Bluetooth pairing / connected
Wireless interface Bluetooth 4.0 (Bluetooth Low Energy), dedicated mobile app, connection up to 10 m (30 ft); Android 4.3 or above
Casing material Aluminum alloy LM20 (charcoal or yellow)
Ingress protection IP66, NEMA 4X
Dimensions 118 x 159 x 93 mm
Weight 1400 g
Lifetime 10 years (excludes sensor)
Operating temperature -40 to 65 °C
Storage temperature 0 to 30 °C
Humidity / pressure 0 to 99 % (non-condensing); 90 to 110 kPa
Connection Pluggable rising clamp style, 0.5 to 2.5 mm2 (20 to 13 AWG)
Hazardous area certification ATEX: II 2 GD, Ex db IIC T6 Gb, Ex tb IIIC T85 °C Db, Tamb -40 to +65 °C. IECEx: Ex db IIC T6 Gb, Ex tb IIIC T85 °C Db. cULus: Class I Div 1 & 2 Groups B, C, D; Class II Div 1 & 2 Groups E, F, G; Class I Zone 1 AEx db IIC T6; Zone 21 AEx tb IIIC T85 °C, IP6X
Other standards Electrical safety EN/IEC/UL 61010-1, CSA C22.2 No. 61010-1-12; EMC EN 50270:2015; radio RED, FCC, IC; gas performance CSA C22.2 No. 152-M1984, UL 2075, AS 1668.2
Accessories Calibration cap, collecting cone, pole mount bracket kit, duct mount kit, weather protection, flow housing
Compatible system controller Touchpoint Plus

Specifications may vary with the ordered configuration. Contact a CAD engineer for sizing to your actual operating conditions.

FAQ

Frequently asked questions about Sensepoint XRL

Which gases does the Sensepoint XRL measure?

Per the datasheet: flammable 0-100 %LEL, O2 0-25 %vol, CO 0-300 ppm, H2 0-1000 ppm, H2S 0-50 ppm or 0-100 ppm. CAD's part-number list also has NO2 20 ppm, SO2 50 ppm and Cl2 5 ppm versions.

What outputs and supply does the Sensepoint XRL have?

Analog 0 to 22 mA output (selectable source or sink) or Modbus RTU. Supply is 24 VDC (mA versions 11 to 32 VDC, Modbus versions 9 to 32 VDC) or 24 VAC.

How is the Sensepoint XRL maintained from a smartphone?

Over Bluetooth 4.0 (BLE) within 10 m using the dedicated app on an Android 4.3 or above device: read gas concentrations, change settings, check history and calibrate with one person without opening the detector.

Used this product? Write a review

Your rating

20 to 1500 characters, no links.

CAD uses your name, company and text only to publish your review once approved. Your email is for CAD to check only; it is never shown or used for anything else.