Honeywell Series 3000 MkII / MkIII Toxic and Oxygen Gas Detector
100% GENUINE
View larger
Honeywell Series 3000 MkII / MkIII Toxic and Oxygen Gas Detector

Honeywell Series 3000 MkII / MkIII Toxic and Oxygen Gas Detector

PRODUCT CODE
Series 3000 MkII / MkIII
BRAND
Honeywell

Series 3000 MkII / MkIII is a Honeywell 2-wire 4-20mA toxic and oxygen gas detector for hazardous areas: MkII flameproof, MkIII intrinsically safe; ATEX/IECEx/UL, IP66.

  • Brand Honeywell
  • Series Series 3000
  • Type 2-wire loop powered toxic and oxygen gas detector for potentially explosive atmospheres (explosion-proof MkII and intrinsically safe MkIII versions)
  • Complete assembly Two parts ordered separately: a transmitter and a sensor
REQUEST A QUOTE DOWNLOAD DATASHEET (PDF)
  • Genuine products
  • Full CO/CQ
  • VAT invoice
  • Quote within 24 working hours

PRODUCT DESCRIPTION

Honeywell Series 3000 MkII / MkIII Toxic and Oxygen Gas Detector

Series 3000 MkII / MkIII is the Honeywell range of 2-wire loop powered 4-20mA toxic and oxygen gas detectors for potentially explosive atmospheres, mounted indoors or outdoors. It uses Surecell electrochemical cells, suited to hot and humid environments, with patented “Reflex” sensing element verification diagnostics; the plug-in sensor can be hot swapped without removing power. Epoxy painted aluminium alloy LM25 or 316 stainless steel housing, IP66 / NEMA 4X.

A complete assembly consists of two parts ordered separately: a transmitter (S3K…) and a sensor chosen by gas. The datasheet lists compliance with ATEX (European), UL (US), c-UL (Canadian), Inmetro (South America) and IECEx (international).

How does Series 3000 MkII differ from MkIII?

The MkII is in a flameproof housing with an intrinsically safe sensor connection, for predominantly Zone 1 applications (Zone 1, 2, 21 or 22 and North American Class I and II Division 1 or 2 areas); with the optional remote mounting kit the MkII sensor can be mounted in a Zone 0 environment. The MkIII is used with a suitable intrinsically safe (IS) barrier, allowing the complete transmitter to be used in Zone 0 applications (Zone 0, 1, 2, 20, 21 or 22). Supply voltage: MkII 17Vdc (±10%) to 32Vdc; MkIII 10Vdc (±10%) to 30Vdc. ATEX/IECEx certified temperature: MkII -20°C to +55°C, MkIII -40°C to +55°C. Transmitter codes S3KAL2, S3KAS2, S3KUL2 and S3KUS2 are MkII; S3KAL3, S3KAS3, S3KUL3 and S3KUS3 are MkIII.

Series 3000 MkII / MkIII specifications

  • Brand: Honeywell
  • Series: Series 3000
  • Type: 2-wire loop powered toxic and oxygen gas detector for potentially explosive atmospheres (explosion-proof MkII and intrinsically safe MkIII versions)
  • Complete assembly: Two parts ordered separately: a transmitter and a sensor
  • Signal: 0-100% FSD 4-20mA; fault = 3mA; calibration due selectable off or 3mA; max. over range 22mA; inhibit (toxic sensors) selectable 3mA or 4mA; inhibit (oxygen sensors) selectable 3mA or 17.4mA
  • MkII power: 2-wire loop powered: 17Vdc (±10%) to 32Vdc (max); 22mA max. over range
  • MkIII power: 2-wire loop powered: 10Vdc (±10%) to 30Vdc (max); 22mA max. overrange; entity parameters for barrier selection: Vmax/Ui = 30Vdc, Imax/Ii = 125mA, Pmax/Pi = 1.2W, Li = 0mH, Ci = 0µF
  • Recommended cable: 2-wire with screen (90% coverage) or conduit; 0.5mm2 (20AWG) to 2.0mm2 (14AWG)
  • Material: Transmitter: epoxy painted aluminium alloy LM25 or 316 stainless steel; sensor: 316 stainless steel with PTFE filter
  • Maximum dimensions: 164mm x 201mm x 99mm (6.4″ x 7.9″ x 3.9″)
  • Weight: Aluminium alloy LM25: 1.7kg (3.75lbs); 316 stainless steel: 3.7kg (8.16lbs)
  • IP rating: IP66 (EN 60529), NEMA 4X
  • Certified temperature: ATEX/IECEx: -20°C to +55°C (-4°F to +131°F), MkIII: -40°C to +55°C (-40°F to +131°F); UL/c-UL: -40°C to +55°C (-40°F to +131°F)
  • Humidity / pressure / storage: Operating humidity continuous 20-90%RH (non-condensing), intermittent 0-99%RH; operating pressure 90-110kPa; storage 15°C to 30°C (59°F to 86°F), 30-70%RH (non-condensing)
  • MkII transmitter approvals: UL/c-UL: Class I, Div. 1 & 2, Groups B, C & D; Class II, Div. 1 Groups E, F & G, Class II, Div. 2, Groups F & G; Class I, Zone 1, Group IIB + H2; ATEX: II 2 (1) GD Ex d [ia IIC Ga] IIB + H2 T4 Gb Ex t [ia IIIC Da] IIIB T135°C Db; IECEx: Ex d [ia IIC Ga] IIB + H2 T4 Gb Ex t [ia IIIC Da] IIIB T135°C Db
  • MkIII transmitter approvals: UL/cUL: Class I, Divisions 1 & 2, Groups A, B, C & D; Class II, Divisions 1 & 2, Groups E, F & G; ATEX: II 1 (1) GD Ex ia IIC T4 Ga Ex ia IIIC T135°C Da; IECEx: Ex ia IIC T4 Ga Ex ia IIIC T135°C Da
  • Remote sensor accessory approvals (MkII and MkIII): UL/c-UL: Class I, Division 1, Groups A, B, C and D; Class II, Divisions 1 and 2, Groups E, F and G; Class 1, Zone 0, Group IIC; Class II, Zone 20; ATEX: II 1G D Ex ia IIC T4 Ga Ex ia IIIC T135°C Da; IECEx: Ex ia IIC T4 Ga Ex ia IIIC T135°C Da
  • Approvals: CE compliant in accordance with: ATEX Directive 94/9/EC, EMC Directive 2004/108/EC, EN 50270

Gases and ranges

From the “Detectable Gases” table of the datasheet.

Gas Selectable full scale range Default range Operating temperature
Oxygen (O2) 25.0% / Vol only 25.0%Vol -30°C to 55°C
Hydrogen sulphide (H2S) 10.0 to 50.0ppm 15.0ppm -40°C to 55°C
Hydrogen sulphide (H2S) 50 to 500ppm 100ppm -40°C to 55°C
Carbon monoxide (CO) 100 to 500ppm 300ppm -40°C to 55°C
Sulphur dioxide (SO2) 5.0 to 20.0ppm 15.0ppm -40°C to 55°C
Ammonia (NH3) * 50 to 200ppm 200ppm -20°C to 40°C (55°C intermittent)
Ammonia (NH3) * 200 to 1,000ppm 1,000ppm -20°C to 40°C
Chlorine (Cl2) 5.0 to 20ppm 5.0ppm -10°C to 55°C
Chlorine dioxide (ClO2) 1.00ppm only 1.00ppm -20°C to 55°C
Nitric oxide (NO) 100ppm only 100ppm -20°C to 55°C
Nitrogen dioxide (NO2) 5.0 to 50.0ppm 10ppm -20°C to 55°C
Hydrogen (H2) 1,000ppm only 1,000ppm -20°C to 55°C
Hydrogen (H2) 9,999ppm only 9,999ppm -20°C to 55°C
Hydrogen chloride (HCl) 10.0 to 20.0ppm 10ppm -20°C to 40°C
Hydrogen cyanide (HCN) 30.0ppm only 30.0ppm -20°C to 55°C
Hydrogen fluoride (HF) 12.0ppm only 12.0ppm -20°C to 55°C
Phosphine (PH3) 1.2ppm only 1.2ppm -20°C to 40°C
Fluorine (F2) 4.00ppm only 4.00ppm -20°C to 55°C
Ozone (O3) 0.400ppm only 0.400ppm -20°C to 55°C
Ethylene oxide (ETO) 20.0 to 50.0ppm 25.0ppm -20°C to 55°C

* Ammonia: suitable for applications without NH3 ambient background concentrations only.

Transmitter order codes

Fourth character: A = ATEX/IECEx, U = UL/c-UL; fifth character: L = LM25 aluminium, S = 316 stainless steel; last character: 2 = MkII, 3 = MkIII.

Transmitter code Description
S3KAL2 ATEX/IECEx approved Series 3000 MkII toxic and oxygen transmitter, Painted Marine Grade Al and 2 x M20 entries
S3KAS2 ATEX/IECEx approved Series 3000 MkII toxic and oxygen transmitter, Stainless Steel 316 and 2 x M20 entries
S3KUL2 UL/cUL approved Series 3000 MkII toxic and oxygen transmitter, Painted Marine Grade Al and 2 x 3/4″NPT entries
S3KUS2 UL/cUL approved Series 3000 MkII toxic and oxygen transmitter, Stainless Steel 316 and 2 x 3/4″NPT entries
S3KAL3 ATEX/IECEx approved Series 3000 MkIII toxic and oxygen transmitter, Painted Marine Grade Al and 2 x M20 entries
S3KAS3 ATEX/IECEx approved Series 3000 MkIII toxic and oxygen transmitter, Stainless Steel 316 and 2 x M20 entries
S3KUL3 UL/cUL approved Series 3000 MkIII toxic and oxygen transmitter, Painted Marine Grade Al and 2 x 3/4″NPT entries
S3KUS3 UL/cUL approved Series 3000 MkIII toxic and oxygen transmitter, Stainless Steel 316 and 2 x 3/4″NPT entries

Sensor codes

Sensor codes per the datasheet; all sensors are certified ATEX, IECEx, UL and CSA (c-UL), and two digits in the code specify the gas type and range.

Sensor code Gas and range
S3KXSO1SS Oxygen (O2) 0-25% Vol
S3KXSC1SS Carbon monoxide (CO) 0-300ppm (default) 0-100 to 0-500ppm selectable
S3KXSC2SS Carbon monoxide (CO) 0-300ppm (default) 0-100 to 0-999ppm selectable
S3KXSH1SS Hydrogen sulphide (H2S) 0-15ppm (default) 0-10 to 0-50ppm selectable
S3KXSH2SS Hydrogen sulphide (H2S) 0-100ppm (default) 0-50 to 0-500ppm selectable
S3KXSL1SS Chlorine (Cl2) 0-5ppm (default) 0-5 to 0-20ppm selectable
S3KXSS1SS Sulphur dioxide (SO2) 0-15ppm (default) 0-5 to 0-20ppm selectable
S3KXSX1SS Chlorine dioxide (ClO2) 0-1ppm only
S3KXSM1SS Nitrogen monoxide (NO) 0-100ppm only
S3KXSN1SS Nitrogen dioxide (NO2) 0-10ppm (default) 0-5 to 0-50ppm selectable
S3KXSG1SS Hydrogen (H2) 0-1000ppm only
S3KXSG2SS Hydrogen (H2) 0-10,000 only
S3KXSR1SS Hydrogen chloride (HCl) 0-10ppm (default) 0-10 to 0-20ppm selectable
S3KXSA1SS Ammonia (NH3) 0-200ppm (default) 0-50 to 0-200ppm selectable
S3KXSA2SS Ammonia (NH3) 0-1000ppm (default) 0-200 to 0-1,000ppm selectable
S3KXSY1SS Hydrogen cyanide (HCN) 0-30ppm only
S3KXSF1SS Hydrogen fluoride (HF) 0-12ppm only
S3KXSP1SS Phosphine (PH3) 0-1.2ppm only
S3KXSU1SS Fluorine (F2) 0-4.00ppm only
S3KXSZ1SS Ozone (O3) 0-0.400ppm only
S3KXSE1SS Ethylene oxide (ETO) 0-25.0ppm (default) 0-20.0 to 0-50.0ppm selectable

Applications

The datasheet lists: exploration and drilling platforms, production platforms, onshore oil and gas terminals, refineries and chemical plants, power plants, waste water facilities and utilities.

TECHNICAL SPECIFICATIONS

Specifications of Honeywell Series 3000 MkII / MkIII Toxic and Oxygen Gas Detector

PARAMETER VALUE
Model Series 3000 MkII / MkIII
Brand Honeywell
Series Series 3000
Type 2-wire loop powered toxic and oxygen gas detector for potentially explosive atmospheres (explosion-proof MkII and intrinsically safe MkIII versions)
Complete assembly Two parts ordered separately: a transmitter and a sensor
Signal 0-100% FSD 4-20mA; fault = 3mA; calibration due selectable off or 3mA; max. over range 22mA; inhibit (toxic sensors) selectable 3mA or 4mA; inhibit (oxygen sensors) selectable 3mA or 17.4mA
MkII power 2-wire loop powered: 17Vdc (±10%) to 32Vdc (max); 22mA max. over range
MkIII power 2-wire loop powered: 10Vdc (±10%) to 30Vdc (max); 22mA max. overrange; entity parameters for barrier selection: Vmax/Ui = 30Vdc, Imax/Ii = 125mA, Pmax/Pi = 1.2W, Li = 0mH, Ci = 0µF
Recommended cable 2-wire with screen (90% coverage) or conduit; 0.5mm2 (20AWG) to 2.0mm2 (14AWG)
Material Transmitter: epoxy painted aluminium alloy LM25 or 316 stainless steel; sensor: 316 stainless steel with PTFE filter
Maximum dimensions 164mm x 201mm x 99mm (6.4" x 7.9" x 3.9")
Weight Aluminium alloy LM25: 1.7kg (3.75lbs); 316 stainless steel: 3.7kg (8.16lbs)
IP rating IP66 (EN 60529), NEMA 4X
Certified temperature ATEX/IECEx: -20°C to +55°C (-4°F to +131°F), MkIII: -40°C to +55°C (-40°F to +131°F); UL/c-UL: -40°C to +55°C (-40°F to +131°F)
Humidity / pressure / storage Operating humidity continuous 20-90%RH (non-condensing), intermittent 0-99%RH; operating pressure 90-110kPa; storage 15°C to 30°C (59°F to 86°F), 30-70%RH (non-condensing)
MkII transmitter approvals UL/c-UL: Class I, Div. 1 & 2, Groups B, C & D; Class II, Div. 1 Groups E, F & G, Class II, Div. 2, Groups F & G; Class I, Zone 1, Group IIB + H2; ATEX: II 2 (1) GD Ex d [ia IIC Ga] IIB + H2 T4 Gb Ex t [ia IIIC Da] IIIB T135°C Db; IECEx: Ex d [ia IIC Ga] IIB + H2 T4 Gb Ex t [ia IIIC Da] IIIB T135°C Db
MkIII transmitter approvals UL/cUL: Class I, Divisions 1 & 2, Groups A, B, C & D; Class II, Divisions 1 & 2, Groups E, F & G; ATEX: II 1 (1) GD Ex ia IIC T4 Ga Ex ia IIIC T135°C Da; IECEx: Ex ia IIC T4 Ga Ex ia IIIC T135°C Da
Remote sensor accessory approvals (MkII and MkIII) UL/c-UL: Class I, Division 1, Groups A, B, C and D; Class II, Divisions 1 and 2, Groups E, F and G; Class 1, Zone 0, Group IIC; Class II, Zone 20; ATEX: II 1G D Ex ia IIC T4 Ga Ex ia IIIC T135°C Da; IECEx: Ex ia IIC T4 Ga Ex ia IIIC T135°C Da
Approvals CE compliant in accordance with: ATEX Directive 94/9/EC, EMC Directive 2004/108/EC, EN 50270

Specifications may vary with the ordered configuration. Contact a CAD engineer for sizing to your actual operating conditions.

FAQ

Frequently asked questions about Series 3000 MkII / MkIII

How does Series 3000 MkII differ from MkIII?

The MkII is a flameproof version with an intrinsically safe sensor connection, mainly for Zone 1 (the sensor can sit in Zone 0 with the remote mounting kit); the MkIII is used with an intrinsically safe barrier so the whole transmitter can be used in Zone 0. Supply: MkII 17-32Vdc, MkIII 10-30Vdc.

Which toxic gases can Series 3000 measure?

Oxygen (O2), H2S, CO, SO2, NH3, Cl2, ClO2, NO, NO2, H2, HCl, HCN, HF, PH3, F2, O3 and ethylene oxide (ETO), each with one or several selectable ranges.

What does a Series 3000 assembly consist of?

A transmitter (for example S3KAL2 or S3KAL3) and a sensor (for example S3KXSC1SS for CO) ordered separately; a 2-wire 4-20mA transmitter, IP66 / NEMA 4X.