Honeywell Series 3000 MkII / MkIII Toxic and Oxygen Gas Detector
Series 3000 MkII / MkIII is a Honeywell 2-wire 4-20mA toxic and oxygen gas detector for hazardous areas: MkII flameproof, MkIII intrinsically safe; ATEX/IECEx/UL, IP66.
- Brand Honeywell
- Series Series 3000
- Type 2-wire loop powered toxic and oxygen gas detector for potentially explosive atmospheres (explosion-proof MkII and intrinsically safe MkIII versions)
- Complete assembly Two parts ordered separately: a transmitter and a sensor
- Genuine products
- Full CO/CQ
- VAT invoice
- Quote within 24 working hours
PRODUCT DESCRIPTION
Honeywell Series 3000 MkII / MkIII Toxic and Oxygen Gas Detector
Series 3000 MkII / MkIII is the Honeywell range of 2-wire loop powered 4-20mA toxic and oxygen gas detectors for potentially explosive atmospheres, mounted indoors or outdoors. It uses Surecell electrochemical cells, suited to hot and humid environments, with patented “Reflex” sensing element verification diagnostics; the plug-in sensor can be hot swapped without removing power. Epoxy painted aluminium alloy LM25 or 316 stainless steel housing, IP66 / NEMA 4X.
A complete assembly consists of two parts ordered separately: a transmitter (S3K…) and a sensor chosen by gas. The datasheet lists compliance with ATEX (European), UL (US), c-UL (Canadian), Inmetro (South America) and IECEx (international).
How does Series 3000 MkII differ from MkIII?
The MkII is in a flameproof housing with an intrinsically safe sensor connection, for predominantly Zone 1 applications (Zone 1, 2, 21 or 22 and North American Class I and II Division 1 or 2 areas); with the optional remote mounting kit the MkII sensor can be mounted in a Zone 0 environment. The MkIII is used with a suitable intrinsically safe (IS) barrier, allowing the complete transmitter to be used in Zone 0 applications (Zone 0, 1, 2, 20, 21 or 22). Supply voltage: MkII 17Vdc (±10%) to 32Vdc; MkIII 10Vdc (±10%) to 30Vdc. ATEX/IECEx certified temperature: MkII -20°C to +55°C, MkIII -40°C to +55°C. Transmitter codes S3KAL2, S3KAS2, S3KUL2 and S3KUS2 are MkII; S3KAL3, S3KAS3, S3KUL3 and S3KUS3 are MkIII.
Series 3000 MkII / MkIII specifications
- Brand: Honeywell
- Series: Series 3000
- Type: 2-wire loop powered toxic and oxygen gas detector for potentially explosive atmospheres (explosion-proof MkII and intrinsically safe MkIII versions)
- Complete assembly: Two parts ordered separately: a transmitter and a sensor
- Signal: 0-100% FSD 4-20mA; fault = 3mA; calibration due selectable off or 3mA; max. over range 22mA; inhibit (toxic sensors) selectable 3mA or 4mA; inhibit (oxygen sensors) selectable 3mA or 17.4mA
- MkII power: 2-wire loop powered: 17Vdc (±10%) to 32Vdc (max); 22mA max. over range
- MkIII power: 2-wire loop powered: 10Vdc (±10%) to 30Vdc (max); 22mA max. overrange; entity parameters for barrier selection: Vmax/Ui = 30Vdc, Imax/Ii = 125mA, Pmax/Pi = 1.2W, Li = 0mH, Ci = 0µF
- Recommended cable: 2-wire with screen (90% coverage) or conduit; 0.5mm2 (20AWG) to 2.0mm2 (14AWG)
- Material: Transmitter: epoxy painted aluminium alloy LM25 or 316 stainless steel; sensor: 316 stainless steel with PTFE filter
- Maximum dimensions: 164mm x 201mm x 99mm (6.4″ x 7.9″ x 3.9″)
- Weight: Aluminium alloy LM25: 1.7kg (3.75lbs); 316 stainless steel: 3.7kg (8.16lbs)
- IP rating: IP66 (EN 60529), NEMA 4X
- Certified temperature: ATEX/IECEx: -20°C to +55°C (-4°F to +131°F), MkIII: -40°C to +55°C (-40°F to +131°F); UL/c-UL: -40°C to +55°C (-40°F to +131°F)
- Humidity / pressure / storage: Operating humidity continuous 20-90%RH (non-condensing), intermittent 0-99%RH; operating pressure 90-110kPa; storage 15°C to 30°C (59°F to 86°F), 30-70%RH (non-condensing)
- MkII transmitter approvals: UL/c-UL: Class I, Div. 1 & 2, Groups B, C & D; Class II, Div. 1 Groups E, F & G, Class II, Div. 2, Groups F & G; Class I, Zone 1, Group IIB + H2; ATEX: II 2 (1) GD Ex d [ia IIC Ga] IIB + H2 T4 Gb Ex t [ia IIIC Da] IIIB T135°C Db; IECEx: Ex d [ia IIC Ga] IIB + H2 T4 Gb Ex t [ia IIIC Da] IIIB T135°C Db
- MkIII transmitter approvals: UL/cUL: Class I, Divisions 1 & 2, Groups A, B, C & D; Class II, Divisions 1 & 2, Groups E, F & G; ATEX: II 1 (1) GD Ex ia IIC T4 Ga Ex ia IIIC T135°C Da; IECEx: Ex ia IIC T4 Ga Ex ia IIIC T135°C Da
- Remote sensor accessory approvals (MkII and MkIII): UL/c-UL: Class I, Division 1, Groups A, B, C and D; Class II, Divisions 1 and 2, Groups E, F and G; Class 1, Zone 0, Group IIC; Class II, Zone 20; ATEX: II 1G D Ex ia IIC T4 Ga Ex ia IIIC T135°C Da; IECEx: Ex ia IIC T4 Ga Ex ia IIIC T135°C Da
- Approvals: CE compliant in accordance with: ATEX Directive 94/9/EC, EMC Directive 2004/108/EC, EN 50270
Gases and ranges
From the “Detectable Gases” table of the datasheet.
| Gas | Selectable full scale range | Default range | Operating temperature |
|---|---|---|---|
| Oxygen (O2) | 25.0% / Vol only | 25.0%Vol | -30°C to 55°C |
| Hydrogen sulphide (H2S) | 10.0 to 50.0ppm | 15.0ppm | -40°C to 55°C |
| Hydrogen sulphide (H2S) | 50 to 500ppm | 100ppm | -40°C to 55°C |
| Carbon monoxide (CO) | 100 to 500ppm | 300ppm | -40°C to 55°C |
| Sulphur dioxide (SO2) | 5.0 to 20.0ppm | 15.0ppm | -40°C to 55°C |
| Ammonia (NH3) * | 50 to 200ppm | 200ppm | -20°C to 40°C (55°C intermittent) |
| Ammonia (NH3) * | 200 to 1,000ppm | 1,000ppm | -20°C to 40°C |
| Chlorine (Cl2) | 5.0 to 20ppm | 5.0ppm | -10°C to 55°C |
| Chlorine dioxide (ClO2) | 1.00ppm only | 1.00ppm | -20°C to 55°C |
| Nitric oxide (NO) | 100ppm only | 100ppm | -20°C to 55°C |
| Nitrogen dioxide (NO2) | 5.0 to 50.0ppm | 10ppm | -20°C to 55°C |
| Hydrogen (H2) | 1,000ppm only | 1,000ppm | -20°C to 55°C |
| Hydrogen (H2) | 9,999ppm only | 9,999ppm | -20°C to 55°C |
| Hydrogen chloride (HCl) | 10.0 to 20.0ppm | 10ppm | -20°C to 40°C |
| Hydrogen cyanide (HCN) | 30.0ppm only | 30.0ppm | -20°C to 55°C |
| Hydrogen fluoride (HF) | 12.0ppm only | 12.0ppm | -20°C to 55°C |
| Phosphine (PH3) | 1.2ppm only | 1.2ppm | -20°C to 40°C |
| Fluorine (F2) | 4.00ppm only | 4.00ppm | -20°C to 55°C |
| Ozone (O3) | 0.400ppm only | 0.400ppm | -20°C to 55°C |
| Ethylene oxide (ETO) | 20.0 to 50.0ppm | 25.0ppm | -20°C to 55°C |
* Ammonia: suitable for applications without NH3 ambient background concentrations only.
Transmitter order codes
Fourth character: A = ATEX/IECEx, U = UL/c-UL; fifth character: L = LM25 aluminium, S = 316 stainless steel; last character: 2 = MkII, 3 = MkIII.
| Transmitter code | Description |
|---|---|
| S3KAL2 | ATEX/IECEx approved Series 3000 MkII toxic and oxygen transmitter, Painted Marine Grade Al and 2 x M20 entries |
| S3KAS2 | ATEX/IECEx approved Series 3000 MkII toxic and oxygen transmitter, Stainless Steel 316 and 2 x M20 entries |
| S3KUL2 | UL/cUL approved Series 3000 MkII toxic and oxygen transmitter, Painted Marine Grade Al and 2 x 3/4″NPT entries |
| S3KUS2 | UL/cUL approved Series 3000 MkII toxic and oxygen transmitter, Stainless Steel 316 and 2 x 3/4″NPT entries |
| S3KAL3 | ATEX/IECEx approved Series 3000 MkIII toxic and oxygen transmitter, Painted Marine Grade Al and 2 x M20 entries |
| S3KAS3 | ATEX/IECEx approved Series 3000 MkIII toxic and oxygen transmitter, Stainless Steel 316 and 2 x M20 entries |
| S3KUL3 | UL/cUL approved Series 3000 MkIII toxic and oxygen transmitter, Painted Marine Grade Al and 2 x 3/4″NPT entries |
| S3KUS3 | UL/cUL approved Series 3000 MkIII toxic and oxygen transmitter, Stainless Steel 316 and 2 x 3/4″NPT entries |
Sensor codes
Sensor codes per the datasheet; all sensors are certified ATEX, IECEx, UL and CSA (c-UL), and two digits in the code specify the gas type and range.
| Sensor code | Gas and range |
|---|---|
| S3KXSO1SS | Oxygen (O2) 0-25% Vol |
| S3KXSC1SS | Carbon monoxide (CO) 0-300ppm (default) 0-100 to 0-500ppm selectable |
| S3KXSC2SS | Carbon monoxide (CO) 0-300ppm (default) 0-100 to 0-999ppm selectable |
| S3KXSH1SS | Hydrogen sulphide (H2S) 0-15ppm (default) 0-10 to 0-50ppm selectable |
| S3KXSH2SS | Hydrogen sulphide (H2S) 0-100ppm (default) 0-50 to 0-500ppm selectable |
| S3KXSL1SS | Chlorine (Cl2) 0-5ppm (default) 0-5 to 0-20ppm selectable |
| S3KXSS1SS | Sulphur dioxide (SO2) 0-15ppm (default) 0-5 to 0-20ppm selectable |
| S3KXSX1SS | Chlorine dioxide (ClO2) 0-1ppm only |
| S3KXSM1SS | Nitrogen monoxide (NO) 0-100ppm only |
| S3KXSN1SS | Nitrogen dioxide (NO2) 0-10ppm (default) 0-5 to 0-50ppm selectable |
| S3KXSG1SS | Hydrogen (H2) 0-1000ppm only |
| S3KXSG2SS | Hydrogen (H2) 0-10,000 only |
| S3KXSR1SS | Hydrogen chloride (HCl) 0-10ppm (default) 0-10 to 0-20ppm selectable |
| S3KXSA1SS | Ammonia (NH3) 0-200ppm (default) 0-50 to 0-200ppm selectable |
| S3KXSA2SS | Ammonia (NH3) 0-1000ppm (default) 0-200 to 0-1,000ppm selectable |
| S3KXSY1SS | Hydrogen cyanide (HCN) 0-30ppm only |
| S3KXSF1SS | Hydrogen fluoride (HF) 0-12ppm only |
| S3KXSP1SS | Phosphine (PH3) 0-1.2ppm only |
| S3KXSU1SS | Fluorine (F2) 0-4.00ppm only |
| S3KXSZ1SS | Ozone (O3) 0-0.400ppm only |
| S3KXSE1SS | Ethylene oxide (ETO) 0-25.0ppm (default) 0-20.0 to 0-50.0ppm selectable |
Applications
The datasheet lists: exploration and drilling platforms, production platforms, onshore oil and gas terminals, refineries and chemical plants, power plants, waste water facilities and utilities.
TECHNICAL SPECIFICATIONS
Specifications of Honeywell Series 3000 MkII / MkIII Toxic and Oxygen Gas Detector
| PARAMETER | VALUE |
|---|---|
| Model | Series 3000 MkII / MkIII |
| Brand | Honeywell |
| Series | Series 3000 |
| Type | 2-wire loop powered toxic and oxygen gas detector for potentially explosive atmospheres (explosion-proof MkII and intrinsically safe MkIII versions) |
| Complete assembly | Two parts ordered separately: a transmitter and a sensor |
| Signal | 0-100% FSD 4-20mA; fault = 3mA; calibration due selectable off or 3mA; max. over range 22mA; inhibit (toxic sensors) selectable 3mA or 4mA; inhibit (oxygen sensors) selectable 3mA or 17.4mA |
| MkII power | 2-wire loop powered: 17Vdc (±10%) to 32Vdc (max); 22mA max. over range |
| MkIII power | 2-wire loop powered: 10Vdc (±10%) to 30Vdc (max); 22mA max. overrange; entity parameters for barrier selection: Vmax/Ui = 30Vdc, Imax/Ii = 125mA, Pmax/Pi = 1.2W, Li = 0mH, Ci = 0µF |
| Recommended cable | 2-wire with screen (90% coverage) or conduit; 0.5mm2 (20AWG) to 2.0mm2 (14AWG) |
| Material | Transmitter: epoxy painted aluminium alloy LM25 or 316 stainless steel; sensor: 316 stainless steel with PTFE filter |
| Maximum dimensions | 164mm x 201mm x 99mm (6.4" x 7.9" x 3.9") |
| Weight | Aluminium alloy LM25: 1.7kg (3.75lbs); 316 stainless steel: 3.7kg (8.16lbs) |
| IP rating | IP66 (EN 60529), NEMA 4X |
| Certified temperature | ATEX/IECEx: -20°C to +55°C (-4°F to +131°F), MkIII: -40°C to +55°C (-40°F to +131°F); UL/c-UL: -40°C to +55°C (-40°F to +131°F) |
| Humidity / pressure / storage | Operating humidity continuous 20-90%RH (non-condensing), intermittent 0-99%RH; operating pressure 90-110kPa; storage 15°C to 30°C (59°F to 86°F), 30-70%RH (non-condensing) |
| MkII transmitter approvals | UL/c-UL: Class I, Div. 1 & 2, Groups B, C & D; Class II, Div. 1 Groups E, F & G, Class II, Div. 2, Groups F & G; Class I, Zone 1, Group IIB + H2; ATEX: II 2 (1) GD Ex d [ia IIC Ga] IIB + H2 T4 Gb Ex t [ia IIIC Da] IIIB T135°C Db; IECEx: Ex d [ia IIC Ga] IIB + H2 T4 Gb Ex t [ia IIIC Da] IIIB T135°C Db |
| MkIII transmitter approvals | UL/cUL: Class I, Divisions 1 & 2, Groups A, B, C & D; Class II, Divisions 1 & 2, Groups E, F & G; ATEX: II 1 (1) GD Ex ia IIC T4 Ga Ex ia IIIC T135°C Da; IECEx: Ex ia IIC T4 Ga Ex ia IIIC T135°C Da |
| Remote sensor accessory approvals (MkII and MkIII) | UL/c-UL: Class I, Division 1, Groups A, B, C and D; Class II, Divisions 1 and 2, Groups E, F and G; Class 1, Zone 0, Group IIC; Class II, Zone 20; ATEX: II 1G D Ex ia IIC T4 Ga Ex ia IIIC T135°C Da; IECEx: Ex ia IIC T4 Ga Ex ia IIIC T135°C Da |
| Approvals | CE compliant in accordance with: ATEX Directive 94/9/EC, EMC Directive 2004/108/EC, EN 50270 |
Specifications may vary with the ordered configuration. Contact a CAD engineer for sizing to your actual operating conditions.
FAQ
Frequently asked questions about Series 3000 MkII / MkIII
How does Series 3000 MkII differ from MkIII?
The MkII is a flameproof version with an intrinsically safe sensor connection, mainly for Zone 1 (the sensor can sit in Zone 0 with the remote mounting kit); the MkIII is used with an intrinsically safe barrier so the whole transmitter can be used in Zone 0. Supply: MkII 17-32Vdc, MkIII 10-30Vdc.
Which toxic gases can Series 3000 measure?
Oxygen (O2), H2S, CO, SO2, NH3, Cl2, ClO2, NO, NO2, H2, HCl, HCN, HF, PH3, F2, O3 and ethylene oxide (ETO), each with one or several selectable ranges.
What does a Series 3000 assembly consist of?
A transmitter (for example S3KAL2 or S3KAL3) and a sensor (for example S3KXSC1SS for CO) ordered separately; a 2-wire 4-20mA transmitter, IP66 / NEMA 4X.