Honeywell Touchpoint Pro Modular Gas Control System
Touchpoint Pro is a Honeywell modular gas control system with up to 64 input and 128 output channels, a 5.7-inch touchscreen, ring network, optional redundant controller and SIL 2.
- Brand Honeywell
- Product type Modular gas control system (central controller, plug-in I/O modules, power and communications rail, plug-in power supplies), centralised or distributed
- Control module display 5.7-inch TFT colour LCD with LED backlight (resistive touch screen), 320 x 240 pixels (QVGA), active area 115.2 x 86.4 mm; front panel 483 x 222 mm
- Controls and indicators LEDs: power (green), alarm (red), fault (yellow), inhibit (yellow); alarm accept and alarm reset buttons, alarm buzzer; 2 system state relays
- Genuine products
- Full CO/CQ
- VAT invoice
- Quote within 24 working hours
PRODUCT DESCRIPTION
Honeywell Touchpoint Pro Modular Gas Control System
Touchpoint Pro is Honeywell’s modular gas control system, built from four main blocks: a central controller with a colour touchscreen, plug-in input / output modules, a power and communications rail and plug-in power supplies. A system can be centralised, distributed or a mix of both, with up to 64 input and 128 output channels, and is SIL 2 certified. It has a Web Server, a self-healing ring network and an optional redundant central controller.
How does Touchpoint Pro differ from Touchpoint Plus and Unipoint?
Touchpoint Pro differs from Touchpoint Plus and Unipoint in scale and architecture. Touchpoint Pro: a modular system mounted in cabinets or racks, up to 64 input and 128 output channels, with remote I/O units linked by a ring network to cut cabling, a 5.7-inch touchscreen, redundancy and SIL 2. Touchpoint Plus: a compact wall-mounted system with 8 channels (16 with an expansion unit), a 7-inch touchscreen and IP65. Unipoint: a DIN-rail controller with one detector input per unit.
Touchpoint Pro specifications
- Brand: Honeywell
- Product type: Modular gas control system (central controller, plug-in I/O modules, power and communications rail, plug-in power supplies), centralised or distributed
- Control module display: 5.7-inch TFT colour LCD with LED backlight (resistive touch screen), 320 x 240 pixels (QVGA), active area 115.2 x 86.4 mm; front panel 483 x 222 mm
- Controls and indicators: LEDs: power (green), alarm (red), fault (yellow), inhibit (yellow); alarm accept and alarm reset buttons, alarm buzzer; 2 system state relays
- Input supply: 18-32 VDC (24 VDC nominal), voltage ripple 50 mVp-p maximum
- Redundancy and communication: Optional redundant Control Centre Board (CCB); self-healing ring network (Ring A / Ring B); redundant RS-485 Modbus RTU interface (optional), Ethernet; Web Server
- Controller operating conditions: -20°C to +55°C (operating and storage); 10% to 90% RH (non-condensing)
- I/O modules: Up to 16 input modules (64 input channels) and 32 output modules (128 output channels) per system. Analogue input module 4-20 mA, 4 channels (2- or 3-wire detectors); analogue input module mV bridge, 4 channels; digital input module, 4 channels; relay output module, 4 channels (4 single pole change over relays)
- Module common specifications: 35.0 x 99.5 x 114.5 mm (H x W x D); 18-32 VDC; DIN rail TS-35 / 15; -40°C to 55°C; 10 to 90% RH (non-condensing)
- Sensors: Catalytic or IR for combustible gas (4-20 mA transmitters); electrochemical for toxic and oxygen; conventional smoke, heat and fire detectors
- Communication / power rail: DIN rail with 1 Ring Coupling Module (RCM) and 5, 7, 9 or 10-way backplanes; single 24 VDC supply connection
- DIN-rail power supplies: 120 W / 240 W / 480 W 24 VDC; Power Supply Redundancy Module (RDN); Uninterruptible Power Supply Module (UPS)
- Back-up battery: 24 V sealed lead acid battery (2 x 12 V in series), 12 Ah or 27 Ah; 300 x 395 x 215 mm; 15.7 kg (12 Ah) or 25 kg (27 Ah)
- Enclosures: Wall mount (600 x 600 x 300, 800 x 600 x 300, 1200 x 600 x 300 mm), 19” 5U rack unit (483 x 222 x 110 mm), floor standing cabinets (2000 x 800 x 600 mm); mild steel
- Approvals: EMC/RFI EN 50270:2006; LVD EN 61010-1:2010; CSA-C22.2 No. 61010-1-04; UL 61010-1 (2nd Edition); ATEX performance EN 50271:2010, EN 60079-29-1, EN 45544-1/-2/-3, EN 50104:2010, C22.2 No. 152-M1984, FM Std. 6310 and 6320; IEC/EN 61508 and EN 50402 SIL 2
System architecture
The central controller is loaded with a sensor catalog of Honeywell gas sensors with default settings, so configuring a channel takes three steps: select the channel ID, program the channel tag, select the sensor and gas. A system can be configured from the touchscreen, from a PC over Ethernet (optional PC configuration software) or monitored remotely through the Web Server (not for critical safety functions such as configuration or calibration). The ring network runs two loops in opposite directions, so a failed module is detected and located without affecting the rest of the system. It accepts inputs from a wide range of flammable and toxic gas detectors, and from most third-party flame detectors, gas detectors and manual call points. The datasheet says the system can reduce total cost per channel by as much as 50% compared with conventional control systems (the manufacturer’s estimate).
Order codes
The codes below are the enclosures from CAD’s document. The datasheet states that detailed ordering information for the controller, I/O modules, power supplies and communications rail is available on request.
| Order code | Description |
|---|---|
| TPPR-V-0602 | 19” 5U Rack Enclosures: 19” 5U Rack Controller Enclosure |
| TPPR-V-0612 | 19” 5U Rack Enclosures: 19” 5U Rack Remote Unit Enclosure |
| TPPR-V-1210 | Wall Mount Controller Enclosures: Dimensions: 600 mm x 600 mm x 300 mm (approx. weight: 37 kg) |
| TPPR-V-1220 | Wall Mount Controller Enclosures: Dimensions: 800 mm x 600 mm x 300 mm (approx. weight: 46 kg) |
| TPPR-V-1230 | Wall Mount Controller Enclosures: Dimensions: 1200 mm x 600 mm x 300 mm (approx. weight: 81 kg) |
| TPPR-V-1215 | Wall Mount Remote Unit Enclosures: Dimensions: 600 mm x 600 mm x 300 mm (weight: 37 kg) |
| TPPR-V-1225 | Wall Mount Remote Unit Enclosures: Dimensions: 800 mm x 600 mm x 300 mm (weight: 46 kg) |
| TPPR-V-1250 | Floor Standing Cabinets – Front Access: No ventilation (dimensions 2000 mm x 800 mm x 600 mm, approx. weight 201 kg) |
| TPPR-V-1252 | Floor Standing Cabinets – Front Access: Natural ventilation (dimensions 2000 mm x 800 mm x 600 mm, approx. weight 201 kg) |
| TPPR-V-1254 | Floor Standing Cabinets – Front Access: Forced ventilation (dimensions 2000 mm x 800 mm x 600 mm, approx. weight 201 kg) |
| TPPR-V-1260 | Floor Standing Cabinets – Rear Access: No ventilation (dimensions 2000 mm x 800 mm x 600 mm, approx. weight 201 kg) |
| TPPR-V-1262 | Floor Standing Cabinets – Rear Access: Natural ventilation (dimensions 2000 mm x 800 mm x 600 mm, approx. weight 201 kg) |
| TPPR-V-1264 | Floor Standing Cabinets – Rear Access: Forced ventilation (dimensions 2000 mm x 800 mm x 600 mm, approx. weight 201 kg) |
| TPPR-V-1241 | Hazardous Area Enclosure: Wall mount stainless steel Div 2 / Zone 2 remote unit enclosure (dimensions 780 mm x 510 mm x 300 mm, approx. weight 42 kg) |
Applications
The datasheet positions Touchpoint Pro for small and medium plants that want to optimise uptime and reduce risk, for new installations, for upgrades and expansions of existing systems (re-using existing cabling) and for system integrators. A distributed configuration cuts cabling cost compared with home-run wiring to a central cabinet.
TECHNICAL SPECIFICATIONS
Specifications of Honeywell Touchpoint
| PARAMETER | VALUE |
|---|---|
| Model | Touchpoint Pro |
| Brand | Honeywell |
| Product type | Modular gas control system (central controller, plug-in I/O modules, power and communications rail, plug-in power supplies), centralised or distributed |
| Control module display | 5.7-inch TFT colour LCD with LED backlight (resistive touch screen), 320 x 240 pixels (QVGA), active area 115.2 x 86.4 mm; front panel 483 x 222 mm |
| Controls and indicators | LEDs: power (green), alarm (red), fault (yellow), inhibit (yellow); alarm accept and alarm reset buttons, alarm buzzer; 2 system state relays |
| Input supply | 18-32 VDC (24 VDC nominal), voltage ripple 50 mVp-p maximum |
| Redundancy and communication | Optional redundant Control Centre Board (CCB); self-healing ring network (Ring A / Ring B); redundant RS-485 Modbus RTU interface (optional), Ethernet; Web Server |
| Controller operating conditions | -20°C to +55°C (operating and storage); 10% to 90% RH (non-condensing) |
| I/O modules | Up to 16 input modules (64 input channels) and 32 output modules (128 output channels) per system. Analogue input module 4-20 mA, 4 channels (2- or 3-wire detectors); analogue input module mV bridge, 4 channels; digital input module, 4 channels; relay output module, 4 channels (4 single pole change over relays) |
| Module common specifications | 35.0 x 99.5 x 114.5 mm (H x W x D); 18-32 VDC; DIN rail TS-35 / 15; -40°C to 55°C; 10 to 90% RH (non-condensing) |
| Sensors | Catalytic or IR for combustible gas (4-20 mA transmitters); electrochemical for toxic and oxygen; conventional smoke, heat and fire detectors |
| Communication / power rail | DIN rail with 1 Ring Coupling Module (RCM) and 5, 7, 9 or 10-way backplanes; single 24 VDC supply connection |
| DIN-rail power supplies | 120 W / 240 W / 480 W 24 VDC; Power Supply Redundancy Module (RDN); Uninterruptible Power Supply Module (UPS) |
| Back-up battery | 24 V sealed lead acid battery (2 x 12 V in series), 12 Ah or 27 Ah; 300 x 395 x 215 mm; 15.7 kg (12 Ah) or 25 kg (27 Ah) |
| Enclosures | Wall mount (600 x 600 x 300, 800 x 600 x 300, 1200 x 600 x 300 mm), 19'' 5U rack unit (483 x 222 x 110 mm), floor standing cabinets (2000 x 800 x 600 mm); mild steel |
| Approvals | EMC/RFI EN 50270:2006; LVD EN 61010-1:2010; CSA-C22.2 No. 61010-1-04; UL 61010-1 (2nd Edition); ATEX performance EN 50271:2010, EN 60079-29-1, EN 45544-1/-2/-3, EN 50104:2010, C22.2 No. 152-M1984, FM Std. 6310 and 6320; IEC/EN 61508 and EN 50402 SIL 2 |
Specifications may vary with the ordered configuration. Contact a CAD engineer for sizing to your actual operating conditions.
FAQ
Frequently asked questions about CAD-SF-420
How does Touchpoint Pro differ from Touchpoint Plus and Unipoint?
Touchpoint Pro is a modular system with up to 64 input and 128 output channels, a 5.7-inch touchscreen, ring network, redundancy and SIL 2. Touchpoint Plus is a wall-mounted system with 8 channels (16 with an expansion unit) and a 7-inch touchscreen. Unipoint is a DIN-rail controller with one detector input per unit.
What does a Touchpoint Pro system consist of?
A central controller with a touchscreen, plug-in I/O modules (4-20 mA, mV, digital, relay), a power and communications rail, and plug-in power supplies (120 W, 240 W, 480 W, redundancy, UPS). Up to 16 input modules (64 channels) and 32 output modules (128 channels).
What communications and redundancy does Touchpoint Pro have?
Ethernet and a Web Server, an optional redundant RS-485 Modbus RTU interface, a self-healing ring network between the I/O units, and an optional redundant Control Centre Board (CCB) that takes over on a fault.