Honeywell XNX Universal Transmitter Gas Detector
XNX Universal Transmitter is a Honeywell universal gas transmitter for catalytic, infrared and electrochemical sensors: 4-20 mA/HART, relay, Modbus or Foundation Fieldbus options, IP66, SIL 2.
- Brand Honeywell
- Type Universal gas transmitter for Honeywell Analytics flammable, toxic and oxygen gas sensors (local or remote)
- Configurations (personalities) mV, EC (electrochemical) or IR (infrared), depending on the sensor fitted
- Standard output 4-20 mA + HART (HART 6.0), selectable sink, source or isolated; accuracy ±1 % of full scale
- Genuine products
- Full CO/CQ
- VAT invoice
- Quote within 24 working hours
PRODUCT DESCRIPTION
Honeywell XNX Universal Transmitter Gas Detector
XNX Universal Transmitter is a Honeywell universal gas transmitter compatible with all Honeywell Analytics gas sensor technologies: catalytic, point infrared, open path infrared and electrochemical. 4-20 mA with HART is standard, with relay, Modbus RTU or Foundation Fieldbus options; aluminium or 316 stainless steel housing, IP66, ATEX, IECEx, UL and CSA approvals and an SIL 2 assessment to IEC 61508.
How does the XNX Universal Transmitter differ from the individual XNX codes?
This page describes the whole XNX transmitter range and all of its order codes. XNX-AMSV-NNCB1, XNX-AMSV-NHCB1, XNX-AMAV-NNCB1 and XNX-AMAV-NHCB1 are four mV configurations supplied with an MPD catalytic sensor, each with its own page; XNXXSO1SS is the oxygen sensor for the EC configuration.
The three XNX configurations
The POD (Personality, Options and Display) sets the transmitter behaviour from the sensor type attached and the selected output options.
| Configuration | Supported sensors |
|---|---|
| mV | mV signal sensors: MPD catalytic, MPD infrared (flammable and CO2), Sensepoint HT (High Temperature), Sensepoint PPM, Model 705 HT |
| EC (electrochemical) | XNX toxic and oxygen sensors (electrochemical cartridges) |
| IR (infrared) | Searchpoint Optima Plus (point) and Searchline Excel (open path) |
XNX Universal Transmitter specifications
- Type: Universal gas transmitter for Honeywell Analytics flammable, toxic and oxygen gas sensors (local or remote)
- Configurations (personalities): mV, EC (electrochemical) or IR (infrared), depending on the sensor fitted
- Standard output: 4-20 mA + HART (HART 6.0), selectable sink, source or isolated; accuracy ±1 % of full scale
- Relay option: 3 configurable relays (2 x SPCO alarm, 1 x SPCO fault), max 240 VAC 5 A (non-inductive); mutually exclusive with Modbus / Foundation Fieldbus
- Modbus option: Modbus RTU, isolated RS485, 1200 to 19.2K baud, up to 254 XNX transmitters
- Foundation Fieldbus option: Multi-drop H1 network, IEC 1158-2 / ISA 50.02, 31.25 Kbit/s, up to 32 nodes
- Local HART port (optional): Externally accessible IS port for hot connection of an HC275/375 HART hand-held configurator or equivalent, cover rated IP66/67
- Housing: 5-coat marine finish painted aluminium alloy or 316 stainless steel
- Cable entries: 5 entries (2 right, 2 left, 1 bottom): M25 for ATEX/IECEx versions, ¾” NPT for UL/CSA versions
- Ingress protection: IP66 (EN 60529:1992), NEMA 4X
- Operating temperature: -40°C to +65°C
- Operating humidity: 0-99 %RH, non-condensing
- Supply voltage: EC and mV versions: 16 to 32 Vdc; IR version: 18 to 32 Vdc (24 Vdc nominal)
- Maximum power: XNX EC: 6.2 W; XNX mV: 6.5 W; XNX IR with Searchpoint Optima Plus: 9.7 W; XNX IR with Searchline Excel receiver: 13.2 W
- Weight: Aluminium alloy: 2.8 kg; 316 stainless steel: 5 kg
- Dimensions: 160 x 197 x 114 mm
- Display: Backlit multilingual LCD (text, bar graph, digits and icons); configured with magnetic switches without opening the unit
- Certification: ATEX: II 2 (1) G Ex d [ia IIC Ga] IIC T4/T6 Gb; II 2 (1) D Ex tb [ia IIIC Da] IIIC T85 Db. IECEx: Ex d [ia IIC Ga] IIC T4/T6 Gb; Ex tb [ia IIIC Da] IIIC T85 Db. UL: Class I, Div 1, Groups A, B, C, D; Class II, Div 1 Groups F & G; Class I, Zone 1 Groups IIB + H2; Class II, Zone 20 & 21. CSA: Class I, Div 1, Groups B, C, D; Class II, Div 1 Groups F & G; Class I, Zone 1 Groups IIB + H2
- Performance standards: SIL assessment to IEC 61508 (SIL 2); EN 45544, EN 50104, EN 50271:2010, EN 13980, EN 60079-29-1; UL 913, UL 1203, CSA 22.2 No. 152; IECEx OD 005
How to read the order code
According to the ordering diagram in the datasheet, the code is built from: approval (A: ATEX/IEC, U: UL-CSA), entry type (M: M25, T: ¾” NPT), material (A: aluminium, S: 316 stainless steel), personality (mV, EC, IR), output option (N: none, R: relay, M: Modbus, F: Foundation Fieldbus), local HART (N: none, H: local HART) and sensor and range (NNN: none, CB1: catalytic bead, IF1: IR hydrocarbons 0-100 %LEL propane, IV1: IR methane 0-100 %LEL or 0-5 %Vol, IC1: IR carbon dioxide 0-5 %Vol). Certain combinations are not available, for example ATEX with ¾” NPT entries.
Order codes
| Order code | Description |
|---|---|
| XNX-AMAV-NNCB1 | XNX Gas Detector, HART® over 4-20mA output, ATEX/IECEx/INMETRO, 4 x M25 entries, painted Aluminium, includes MPD catalytic sensor 0-100%LEL |
| XNX-AMAV-NHCB1 | XNX Gas Detector, HART® over 4-20mA output and local HART® interface port, ATEX/IECEx/INMETRO, 3 x M25 entries, painted Aluminium, includes MPD catalytic sensor 0-100%LEL |
| XNX-AMAV-RNCB1 | XNX Gas Detector, HART® over 4-20mA output and 3 fault/alarm relays, ATEX/IECEx/INMETRO, 4 x M25 entries, painted Aluminium, includes MPD catalytic sensor 0-100%LEL |
| XNX-AMAV-RHCB1 | XNX Gas Detector, HART® over 4-20mA output, 3 fault/alarm relays and local HART® interface port, ATEX/IECEx/INMETRO, 3 x M25 entries, painted Aluminium, includes MPD catalytic sensor 0-100%LEL |
| XNX-AMAV-MNCB1 | XNX Gas Detector, HART® over 4-20mA and Modbus output, ATEX/IECEx/INMETRO, 4 x M25 entries, painted Aluminium, includes MPD catalytic sensor 0-100%LEL |
| XNX-AMAV-MHCB1 | XNX Gas Detector, HART® over 4-20mA and Modbus output and local HART® interface port, ATEX/IECEx/INMETRO, 3 x M25 entries, painted Aluminium, includes MPD catalytic sensor 0-100%LEL |
| XNX-AMSV-NNCB1 | XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, including MPD catalytic sensor 0-100%LEL. |
| XNX-AMSV-NHCB1 | XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with local HART® interface port, including MPD catalytic sensor 0-100%LEL. |
| XNX-AMSV-RNCB1 | XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with alarm and fault relay outputs, including MPD catalytic sensor 0-100%LEL. |
| XNX-AMSV-RHCB1 | XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with alarm and fault relay outputs and local HART® interface port, including MPD catalytic sensor 0-100%LEL. |
| XNX-AMSV-MNCB1 | XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with Modbus® output, including MPD catalytic sensor 0-100%LEL. |
| XNX-AMSV-MHCB1 | XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with Modbus® output and local HART® interface port, including MPD catalytic sensor 0-100%LEL. |
| XNX-AMAV-NNNNN | XNX Transmitter, HART® over 4-20mA output, ATEX/IECEx, 5 x M25 entries, painted Aluminium, configured for Sensepoint High Temperature Sensor |
| XNX-AMSV-NNNNN | XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, configured for mV sensors. |
| XNX-AMAE-NNNNN | XNX Transmitter, HART® over 4-20mA output, ATEX/IECEx/INMETRO, 4 x M25 entries, painted Aluminium, configured for XNX toxic and oxygen sensors |
| XNX-AMSE-NNNNN | XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, configured for XNX toxic and oxygen sensors. |
| XNX-AMAI-NNNNN | XNX Transmitter, HART® over 4-20mA output, ATEX/IECEx, 5 x M25 entries, painted Aluminium, configured for Optima Plus and Excel |
| XNX-AMSI-NNNNN | XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, configured for Optima Plus and Searchline Excel. |
Applications
The Honeywell datasheet lists these typical applications: offshore oil and gas production platforms, oil and gas exploration and drilling, refineries, chemical and petrochemical plants, onshore oil and gas terminals, gas transmission, power stations.
TECHNICAL SPECIFICATIONS
Specifications of Honeywell XNX
| PARAMETER | VALUE |
|---|---|
| Model | XNX Universal Transmitter |
| Brand | Honeywell |
| Type | Universal gas transmitter for Honeywell Analytics flammable, toxic and oxygen gas sensors (local or remote) |
| Configurations (personalities) | mV, EC (electrochemical) or IR (infrared), depending on the sensor fitted |
| Standard output | 4-20 mA + HART (HART 6.0), selectable sink, source or isolated; accuracy ±1 % of full scale |
| Relay option | 3 configurable relays (2 x SPCO alarm, 1 x SPCO fault), max 240 VAC 5 A (non-inductive); mutually exclusive with Modbus / Foundation Fieldbus |
| Modbus option | Modbus RTU, isolated RS485, 1200 to 19.2K baud, up to 254 XNX transmitters |
| Foundation Fieldbus option | Multi-drop H1 network, IEC 1158-2 / ISA 50.02, 31.25 Kbit/s, up to 32 nodes |
| Local HART port (optional) | Externally accessible IS port for hot connection of an HC275/375 HART hand-held configurator or equivalent, cover rated IP66/67 |
| Housing | 5-coat marine finish painted aluminium alloy or 316 stainless steel |
| Cable entries | 5 entries (2 right, 2 left, 1 bottom): M25 for ATEX/IECEx versions, ¾" NPT for UL/CSA versions |
| Ingress protection | IP66 (EN 60529:1992), NEMA 4X |
| Operating temperature | -40°C to +65°C |
| Operating humidity | 0-99 %RH, non-condensing |
| Supply voltage | EC and mV versions: 16 to 32 Vdc; IR version: 18 to 32 Vdc (24 Vdc nominal) |
| Maximum power | XNX EC: 6.2 W; XNX mV: 6.5 W; XNX IR with Searchpoint Optima Plus: 9.7 W; XNX IR with Searchline Excel receiver: 13.2 W |
| Weight | Aluminium alloy: 2.8 kg; 316 stainless steel: 5 kg |
| Dimensions | 160 x 197 x 114 mm |
| Display | Backlit multilingual LCD (text, bar graph, digits and icons); configured with magnetic switches without opening the unit |
| Certification | ATEX: II 2 (1) G Ex d [ia IIC Ga] IIC T4/T6 Gb; II 2 (1) D Ex tb [ia IIIC Da] IIIC T85 Db. IECEx: Ex d [ia IIC Ga] IIC T4/T6 Gb; Ex tb [ia IIIC Da] IIIC T85 Db. UL: Class I, Div 1, Groups A, B, C, D; Class II, Div 1 Groups F & G; Class I, Zone 1 Groups IIB + H2; Class II, Zone 20 & 21. CSA: Class I, Div 1, Groups B, C, D; Class II, Div 1 Groups F & G; Class I, Zone 1 Groups IIB + H2 |
| Performance standards | SIL assessment to IEC 61508 (SIL 2); EN 45544, EN 50104, EN 50271:2010, EN 13980, EN 60079-29-1; UL 913, UL 1203, CSA 22.2 No. 152; IECEx OD 005 |
Specifications may vary with the ordered configuration. Contact a CAD engineer for sizing to your actual operating conditions.
OTHER CODES IN THE RANGE
Same series
- XNX-AMAV-NHCB1 Honeywell XNX-AMAV-NHCB1 Fixed Gas Detector, Aluminium, HART 4-20 mA, Local HART Port
- XNX-AMAV-NNCB1 Honeywell XNX-AMAV-NNCB1 Fixed Gas Detector, Aluminium, HART 4-20 mA
- XNX-AMSV-NHCB1 Honeywell XNX-AMSV-NHCB1 Fixed Gas Detector, 316 Stainless Steel, HART 4-20 mA, Local HART Port
- XNX-AMSV-NNCB1 Honeywell XNX-AMSV-NNCB1 Fixed Gas Detector, 316 Stainless Steel, HART 4-20 mA
- XNXXSO1SS Honeywell XNXXSO1SS Oxygen Sensor for XNX Gas Detector, 0-25 %Vol
FAQ
Frequently asked questions about CAD-SF-430
What configurations and outputs does the XNX Universal Transmitter have?
Three configurations: mV, EC (electrochemical) and IR (infrared). 4-20 mA with HART is standard; options are 3 relays, Modbus RTU or Foundation Fieldbus (mutually exclusive) and a local HART port.
Which sensors work with the XNX Universal Transmitter?
All Honeywell Analytics fixed gas sensors: Searchline Excel, Searchpoint Optima Plus, Sensepoint (HT and PPM), Model 705, the MPD catalytic / infrared sensors and the XNX toxic and oxygen sensors.
What ingress protection and approvals does the XNX Universal Transmitter have?
IP66, NEMA 4X, operating temperature -40°C to +65°C. ATEX, IECEx, UL and CSA certification for hazardous areas; SIL 2 assessment to IEC 61508.