Kidde KI-PD Photoelectric Smoke Detector
100% GENUINE
View larger
Kidde KI-PD Photoelectric Smoke Detector

Kidde KI-PD Photoelectric Smoke Detector

PRODUCT CODE
CAD-SF-440
BRAND
Kidde
PRODUCT LINE
KI Series

Kidde KI-PD is an intelligent addressable photoelectric smoke detector for Kidde VS and VM series panels: up to 250 addresses per loop, 0.53–3.94 %/ft sensitivity, five sensitivity settings, dirty-detector diagnostics. For multi-use buildings and slow smouldering fires; UL 268.

  • Brand Kidde
  • Detector type Intelligent Optical Smoke Detector
  • Smoke sensitivity range 0.53 to 3.94 %/ft. (1.7 to 12.35 %/m) obscuration
  • Addresses Up to 250 addresses per loop
REQUEST A QUOTE DOWNLOAD DATASHEET (PDF)
  • Genuine products
  • Full CO/CQ
  • VAT invoice
  • Quote within 24 working hours

PRODUCT DESCRIPTION

Kidde KI-PD Photoelectric Smoke Detector

Standard Features
Note: Some features described here may not be supported by all control systems. Check your control panel’s Installation and Operation Guide for details.
• Next generation optical smoke sensing technology
• Wide 0.53 to 3.94 %/ft. (1.7 to 12.35 %/m) smoke obscuration
• Uses Existing Wiring
• Automatic Device Mapping
• Up To 250 Total Addresses Per Loop
• Two Levels of Environmental Compensation
• Two Levels of Dirty Detector Warning
• Twenty Pre-Alarm Settings
• Five Sensitivity Settings
• Non-Volatile Memory
• Electronic Addressing
• Identification of Dirty or Defective Detectors
• Automatic Day/Night Sensitivity Adjustment
• Bicolor (Green/Red) Status Led
• Standard, Relay, Fault Isolator, and Audible Mounting Bases
• Sensor Markings Provide Easy Testing Identification

Application
The KI-PD detects extremely small particles of combustion and
triggers an alarm at the first sign of smoke. Thanks to its high
performance forward-scattering reflective response technology,
the photoelectric smoke sensor responds quickly and reliably to
a wide range of fire types, espe cially slow burning fires fuelled by
combustibles typically found in modern multi-use buildings.
Compatibility
The KI-PD detector is compatible with Kidde VS and VM series
panels

Compatibility and bases

According to the Kidde datasheet, the KI-PD is compatible with Kidde VS and VM series panels. Some features may not be supported by every control system; check the panel’s installation and operation guide. The detector needs a separate mounting base:

Code Description
KI-SB / KI-SB4 Standard base (KI-SB4: 4-inch base with GSA-TS4 trim skirt); supports the GSA-LED remote LED
KI-RB / KI-RB4 Base with relay (dry contact 1 A pilot duty @ 30 VDC; normally open or closed selected at installation)
KI-IB / KI-IB4 Base with a built-in line fault isolator for Class A circuits
KI-ABST Sounder base for fire (smoke and heat) detectors
KI-ABLT 520 Hz low-frequency sounder base for fire and CO detectors
KI-ABDT Sounder base for fire and CO detectors when used with a GSA-T3T4 temporal pattern generator
GSA-LED Remote alarm LED (connects to the KI-SB or KI-SB4 only; not for EN 54 applications)
GSA-TS4 / GSA-TS Trim skirt (supplied with 4-inch bases; GSA-TS ordered separately to hide surface imperfections)
GSA-DMP Detector mounting plate

Installation

  • Bases mount to North American 1-gang boxes, 3-1/2 or 4 inch octagon boxes 38 mm (1-1/2 inch) deep, and European BESA and 1-gang boxes with 60.3 mm fixing centres; the KI-SB4, KI-RB4 and KI-IB4 also mount to 4 inch square boxes.
  • Wiring terminals are accessible from the room side and accept 18, 16, 14 and 12 AWG wire (0.75 – 2.5 mm²); 18 and 16 AWG are preferred.
  • Wall mounting: maximum 305 mm (12 in.) from the ceiling. Air velocity 0 to 20 m/s (0 to 4,000 ft/min).

Operating conditions, standards and cautions

  • Operating environment 0 to 49 °C (0 – 93% RH, non-condensing); storage -20 to 60 °C; shipping weight about 0.16 kg.
  • Agency listings per the datasheet: CAN/ULC-S529, UL 268, UL 268A. In Canada install according to CAN/ULC-S524, CSA C22.1 and the local authority.
  • The detector does not operate without power and does not sense fires where smoke cannot reach it; photoelectric detectors are best suited to slow, smouldering fires.
  • A sensitivity report can be printed to satisfy NFPA sensitivity measurements (end of the first year and every two years thereafter).

Information to send with a quote request

So that CAD can quote within 24 working hours, please send:

  • The Kidde panel in use or planned (VS or VM series) and the number of addresses on the loop.
  • The number of KI-PD detectors and the bases needed (standard, relay, isolator, sounder).
  • Accessories: GSA-LED remote LED, detector tester (Testifire), mounting plate.
  • Any approvals or certificates the project requires (for example UL, EN 54, local fire-department certificates).

TECHNICAL SPECIFICATIONS

Specifications of Kidde KI Series

PARAMETER VALUE
Model KI-PD
Brand Kidde
Detector type Intelligent Optical Smoke Detector
Smoke sensitivity range 0.53 to 3.94 %/ft. (1.7 to 12.35 %/m) obscuration
Addresses Up to 250 addresses per loop
Operating voltage 15.20 to 19.95 VDC
Current draw Normal 51 µA; alarm 68 µA
Operating environment 32 to 120 °F (0 to 49 °C), 0 to 93% RH, non-condensing
Material High Impact Engineering Polymer, white
Standards CAN/ULC-S529, UL 268, UL 268A

Specifications may vary with the ordered configuration. Contact a CAD engineer for sizing to your actual operating conditions.

FAQ

Frequently asked questions about CAD-SF-440

Which fire panels is the Kidde KI-PD smoke detector compatible with?

According to the Kidde datasheet the KI-PD is compatible with Kidde VS and VM series panels. Some features depend on the panel; check the panel guide or send the panel model so CAD can confirm.

Which base does the KI-PD need, and are there sounder or relay bases?

The KI-PD needs a separate base: KI-SB/KI-SB4 (standard), KI-RB/KI-RB4 (relay), KI-IB/KI-IB4 (fault isolator, Class A circuits) and the KI-ABST, KI-ABLT and KI-ABDT sounder bases. See the bases table above.

What kind of fire is the KI-PD best at detecting?

It is a forward-scattering photoelectric detector that senses extremely small particles of combustion at the first sign of smoke and responds quickly to a wide range of fire types, especially slow-burning fires fuelled by combustibles typical of modern multi-use buildings. Smoke sensitivity range 0.53 to 3.94 %/ft (1.7 to 12.35 %/m).

What approvals does the KI-PD have?

The datasheet lists CAN/ULC-S529, UL 268 and UL 268A; it does not list EN 54. If your project requires EN 54 or another approval, send an enquiry and CAD will confirm with the manufacturer.

What do I send to get a quote for the KI-PD?

Send the Kidde panel series, number of detectors, bases and accessories, and any approvals required. CAD quotes within 24 working hours.

Used this product? Write a review

Your rating

20 to 1500 characters, no links.

CAD uses your name, company and text only to publish your review once approved. Your email is for CAD to check only; it is never shown or used for anything else.

MORE IN SAFETY SOLUTION

RELATED PRODUCTS

View the full equipment catalogue