ToxiRAE Pro Family
Honeywell RAE ToxiRAE Pro is a personal toxic gas and oxygen monitor, diffusion sampling, with over 20 field-replaceable electrochemical sensors (NH3, CO, Cl2, H2S, O2, PH3, SO2 and more), Li-ion battery over 30 hours, Man Down alarm, IP-65, optional wireless. CSA, ATEX and IECEx certified.
- Size 4.6" H x 2.4" W x 1.2" D (118 x 60 x 30 mm)
- Weight 7.76 oz. (220 g)
- Sensors More than 20 intelligent, field-replaceable electrochemical sensors
- Battery Rechargeable Li-ion battery
- Genuine products
- Full CO/CQ
- VAT invoice
- Quote within 24 working hours
PRODUCT DESCRIPTION
ToxiRAE Pro Family
The ToxiRAE Pro is a gas detector that can detect a wide range of gases, from carbon monoxide, hydrogen sulfide and oxygen to ammonia, chlorine and formaldehyde. It stores calibration data, so users can monitor one toxic gas one day and a different gas the next simply by swapping the sensor in the ToxiRAE Pro.
Gases and measuring ranges:
- AMMONIA (NH3) 0 to 100 ppm
- CARBON MONOXIDE (CO) 0 to 500 ppm
- CARBON MONOXIDE (CO) 0 to 2,000 ppm
- EXT. RANGE CARBON MONOXIDE (CO), H2-COMP. 0 to 2,000 ppm
- CHLORINE (CI2) 0 to 50 ppm
- CHLORINE DIOXIDE (CIO2) 0 to 1 ppm
- ETHYLENE OXIDE (ETO-A) 0 to 100 ppm
- ETHYLENE OXIDE (ETO-B) 0 to 10 ppm
- ETHYLENE OXIDE (ETO-C), EXT. RANGE 0 to 500 ppm
- FORMALDEHYDE (HCHO) 0 to 10 ppm
- HYDROGEN (H2) 0 to 1,000 ppm
- HYDROGEN CYANIDE (HCN) 0 to 50 ppm
- HYDROGEN SULFIDE (H2S) 0 to 100 ppm
- HYDROGEN SULFIDE (H2S), EXT. RANGE 0 to 1,000 ppm
- METHYL MERCAPTAN (CH3-SH) 0 to 10 ppm
- NITRIC OXIDE (NO) 0 to 250 ppm
- NITROGEN DIOXIDE (NO2) 0 to 20 ppm
- OXYGEN (O2) 0 to 30% Vol
- PHOSPHINE (PH3) 0 to 20 ppm
- SULFUR DIOXIDE (SO2) 0 to 20 ppm
Specifications:
SIZE: 4.6" H x 2.4" W x 1.2" D (118 x 60 x 30 mm)
WEIGHT: 7.76 oz. (220 g)
SENSORS: More than 20 interchangeable, field-replaceable intelligent electrochemical sensors
BATTERY: Rechargeable Li-ion battery
– Run time: > 30 hours (normal operation, wireless off)
– Recharge time: < 4 hours via charging cradle
DISPLAY: LCD with white LED backlight (activated by an alarm condition or by pressing a button)
DISPLAY READOUT: Real-time gas concentration in parts per million (ppm) or mg/m3; battery status; datalogging on/off; wireless on/off and reception quality
SAMPLING: Diffusion; automatic with the AutoRAE 2 Test and Calibration System, or manual
ALARM MODES:
– Wireless remote alarm notification; audible (95 dB @ 30 cm), vibration, visible (flashing bright red LEDs) and on-screen indication of alarm conditions.
– Man Down Alarm with pre-alarm and real-time wireless remote notification
DATALOGGING:
– Data storage: three months (at one-minute intervals)
– Sampling interval adjustable from 1 to 3,600 seconds
COMMUNICATION AND DATA DOWNLOAD:
– Download of logged data via PC
– Data download via the AutoRAE 2 Automatic Test and Calibration System
– Data and status transmission via built-in RF modem (optional)
WIRELESS NETWORK: ProRAE Guardian real-time wireless safety system or closed-loop network with EchoView Host
WIRELESS RANGE (TYPICAL): ToxiRAE Pro to Mesh Router, EchoView Host or Mesh Reader2 ~ 660 feet (200 meters); ToxiRAE Pro to RAELink3 Mesh or RAELink3 Z1 Mesh modem ~ 330 feet (100 meters)
OPERATING TEMPERATURE: -4° to 131°F (-20° to 55°C)
HUMIDITY: 0% to 95% relative humidity (non-condensing)
RATING: IP-65
SAFETY CERTIFICATIONS: CSA: Class I, Division 1, Groups A, B, C and D, T-code T4; Class I, Zone 0 A/Ex ia IIC T4. ATEX: II 1G, Ex ia IIC Ga T4. IECEx: Ex ia IIC Ga T4. China Ex: Ex ia IIC T4
Choosing the sensor and range
According to the manufacturer’s data sheet (DS-1064-11), the ToxiRAE Pro uses intelligent electrochemical sensors that store calibration data, so a sensor can be swapped to monitor a different gas the next day. Main ranges (resolution in brackets):
- NH3 0-100 ppm (1 ppm); CO 0-500 ppm (1 ppm) or 0-2,000 ppm (10 ppm); Cl2 0-50 ppm (0.1 ppm); ClO2 0-1 ppm (0.03 ppm).
- H2S 0-100 ppm (0.1 ppm) or 0-1,000 ppm (1 ppm); SO2 0-20 ppm (0.1 ppm); NO2 0-20 ppm (0.1 ppm); NO 0-250 ppm (0.5 ppm).
- O2 0-30% Vol. (0.1%); PH3 0-20 ppm (0.1 ppm); HCN 0-50 ppm (0.5 ppm); H2 0-1,000 ppm (10 ppm); HCHO 0-10 ppm (0.05 ppm).
- Ethylene oxide has three ranges (0-100, 0-10 and 0-500 ppm); methyl mercaptan 0-10 ppm.
Operation and safety
- Diffusion sampling; graphical LCD with backlight; readings in ppm or mg/m3 with STEL, TWA and peak values; two buttons.
- Alarms: audible 95 dB at 30 cm, vibration, flashing red LEDs and on-screen indication; Man Down with pre-alarm and real-time remote notification (wireless version).
- Continuous datalogging with a three-month capacity at one-minute intervals; configurable interval from 1 to 3,600 seconds; data download through the charging cradle and PC cable.
- Rechargeable Li-ion battery, over 30 hours of operation (non-wireless), recharge in under 4 hours.
- 118 x 60 x 30 mm, 220 g; IP-65; -20 to +55 °C; humidity 0 to 95% non-condensing.
- Manual calibration or automatic with the AutoRAE 2 system (the manufacturer states “contact Honeywell RAE Systems for availability”); the manufacturer recommends calibrating the sensors on installation.
Wireless and approvals
The wireless version uses a licence-free ISM-band RF modem and connects to the ProRAE Guardian system or an EchoView Host closed-loop network; typical range is about 200 m to a mesh router or EchoView Host and about 100 m to a RAELink3 modem. Wireless and non-wireless are separate configurations; a non-wireless unit cannot be upgraded. Approvals per the data sheet: CSA Class I Div. 1 Groups A, B, C, D, T4; ATEX II 1G Ex ia IIC Ga T4; IECEx Ex ia IIC Ga T4; China Ex Ex ia IIC T4. Country-specific wireless approvals: ask the manufacturer.
What to send for a quote
- Gases to measure and the range (ppm or % Vol.), and number of sensors.
- Wireless or non-wireless, and the receiving system (ProRAE Guardian, EchoView).
- Whether you need AutoRAE 2 automatic calibration or a multi-unit charging station.
- Hazardous-area approvals required and quantity.
CAD replies with a quote within 24 working hours of receiving the details.
TECHNICAL SPECIFICATIONS
Specifications of RAE Systems ToxiRAE
| PARAMETER | VALUE |
|---|---|
| Model | ToxiRAE Pro |
| Size | 4.6" H x 2.4" W x 1.2" D (118 x 60 x 30 mm) |
| Weight | 7.76 oz. (220 g) |
| Sensors | More than 20 intelligent, field-replaceable electrochemical sensors |
| Battery | Rechargeable Li-ion battery |
| Battery run time | > 30 hours (normal operation, wireless off) |
| Recharge time | < 4 hours via charging cradle |
| Display | LCD with white LED backlight (activated by an alarm or by pressing a button) |
| Sampling | Diffusion |
| Data storage | three months (at one-minute intervals) |
| Wireless network | ProRAE Guardian real-time wireless safety system or closed-loop network with EchoView Host |
| Operating temperature | -4 °F to 131 °F (-20 °C to 55 °C) |
| Ingress protection | IP-65 |
| Brand | RAE Systems |
| Humidity | 0% to 95% relative humidity (non-condensing) |
Specifications may vary with the ordered configuration. Contact a CAD engineer for sizing to your actual operating conditions.
FAQ
Frequently asked questions about CAD-SF-400
Which gases can the ToxiRAE Pro measure?
Over 20 replaceable electrochemical sensors: NH3, CO, Cl2, ClO2, ethylene oxide, formaldehyde, H2, HCN, H2S, methyl mercaptan, NO, NO2, O2, PH3 and SO2, each with its own range.
Can one unit measure several gases at once?
The ToxiRAE Pro is a personal monitor that takes one sensor per configuration; swap the sensor to measure another gas. If you need simultaneous multi-gas measurement, see the MultiRAE Pro.
What is different about the wireless version?
It has an RF modem that sends readings and alarms (including Man Down) to the ProRAE Guardian system or an EchoView network, with a typical range of 100 to 200 m depending on the receiver. A non-wireless unit cannot be upgraded to wireless.
How long does the battery last?
Over 30 hours of normal operation (non-wireless), recharged in under 4 hours through the cradle.
What do I need to send for a ToxiRAE Pro quote?
Gases and ranges, wireless or non-wireless, AutoRAE 2 needs, approvals required and quantity. CAD replies within 24 working hours.