RAE Systems MultiRAE Pro Multi-Gas Monitor
Honeywell RAE MultiRAE Pro is a portable multi-gas monitor with a built-in pump (250 cc/min): over 25 replaceable sensors covering gamma radiation, PID for VOCs, LEL and NDIR combustibles, CO2, toxic gases and O2. IP-65, -20 to +50 °C, Man Down alarm, optional wireless. CSA, ATEX and IECEx certified.
- Hazardous area approvals (standard) CSA Class I, Div. 1, Groups A, B, C, D, T4; ATEX 0575 II 1G Ex ia IIC T4 Ga; IECEx Ex ia IIC T4 Ga
- Hazardous area approvals (with IR sensor) ATEX 2G Ex ia d IIC T4 Gb; IECEx Ex ia d IIC T4 Gb
- Brand RAE Systems
- Dimensions 7.6" H x 3.8" W x 2.6" D (193 x 96.5 x 66 mm)
- Genuine products
- Full CO/CQ
- VAT invoice
- Quote within 24 working hours
PRODUCT DESCRIPTION
RAE Systems MultiRAE Pro Multi-Gas Monitor
The MultiRAE Pro is highly versatile, accepting up to 25 interchangeable sensors to monitor a wide range of hazards, including volatile organic compounds (VOCs), toxic gases, combustible gases and O2 levels, as well as gamma radiation. Its large, intuitive display and easily replaced sensors make it simple to use and calibrate, and 5 alarm types, including a low alarm, give you the flexibility to detect and respond to incidents quickly.
- Intuitive display shows 1-3 hazardous gases at once
- Flexible and customizable for different applications
- Real-time Man Down Alarm
- Field-replaceable sensors, pump and battery
- Fully automatic bump testing and calibration with AutoRAE 21
Measuring range by gas
- Gamma 0 to 20,000 microREM/h to 4.29 REM (dose range)
- VOC 10.6 eV (HR) 0 to 5,000 ppm
- VOC 10.6 eV (ppb) 0 to 2,000 ppm
- VOC 9.8 eV1 0 to 1,000 ppm
- Catalytic LEL 0 to 100% LEL
- NDIR (0-100% LEL Methane) 0 to 100% LEL
- NDIR (0-100% Vol. Methane) 0 to 100% Vol
- Carbon Dioxide (CO2) NDIR 0 to 50,000 ppm 100 ppm
- Ammonia (NH3) 0 to 100 ppm 1 ppm
- Carbon Monoxide (CO) 0 to 500 ppm
- Carbon Monoxide (CO), Ext. Range 0 to 2,000 ppm
- Carbon Monoxide (CO), H2-comp 0 to 2,000 ppm
- Carbon Monoxide (CO) 0 to 500 ppm
- Hydrogen Sulfide (H2S) Combo 0 to 200 ppm
- Chlorine (Cl2) 0 to 50 ppm 0.1 ppm
- Chlorine Dioxide (ClO2) 0 to 1 ppm 0.03 ppm
- Ethylene Oxide (EtO-A) 0 to 100 ppm
- Ethylene Oxide (EtO-B) 0 to 10 ppm
- Ethylene Oxide (EtO-C), Ext. 0 to 500 ppm
- Formaldehyde (HCHO) 0 to 10 ppm
- Hydrogen (H2) 0 to 1,000 ppm 2 ppm
- Hydrogen Chloride (HCl) 0 to 15 ppm
- Hydrogen Cyanide (HCN) 0 to 50 ppm
- Hydrogen Fluoride (HF) 0 to 10 ppm
- Hydrogen Sulfide (H2S) 0 to 100 ppm
- Hydrogen Sulfide (H2S), Ext. Range 0 to 1,000 ppm
- Methyl Mercaptan (CH3-SH) 0 to 10 ppm
- Nitric Oxide (NO) 0 to 250 ppm 0.5 ppm
- Nitrogen Dioxide (NO2) 0 to 20 ppm
- Oxygen (O2) 0 to 30% Vol
- Phosgene (COCl2) 0 to 1 ppm
- Phosphine (PH3) 0 to 20 ppm
- Phosphine (PH3), Ext. Range 0 to 1,000 ppm
- Sulfur Dioxide (SO2) 0 to 20 ppm
- Dimensions 7.6 “H x 3.8” W x 2.6 “D (193 x 96.5 x 66 mm)
- Weight 31 oz. (880 g)
Battery options
- Rechargeable Li-ion battery (runtime ~ 12 hours, recharge time <6 hours)
- Extended-duration rechargeable Li-ion battery (runtime ~ 18 hours, recharge time <9 hours)
- Alkaline battery adapter (A) with 4 x AA batteries (runtime ~ 6 hours)
- LCD display (128 x 160) with indicator lights
- STEL (short-term exposure limit), TWA (time-weighted average) values, peak and minimum values
- Keypad buttons: 3 operation and programming keys (Mode, Y / + and N / -)
- Built-in sampling pump. Average flow rate: 250 cc / min. Automatic shutoff under low-flow conditions
- Automatic calibration with the AutoRAE 21 test and calibration system, or manual
Data logging
- Continuous data logging (6 months for 5 sensors at 1-minute intervals, 24/7)
- User-configurable data logging interval (1 to 3,600 seconds)
- Data download, instrument setup and upgrades on a PC via the travel charger
- Data transmission and status notification via built-in RF modem (optional)
- Operating range 656 feet (200 meters)
- Operating temperature -4 ° to 122 ° F (-20 ° to 50 ° C)
- Humidity 0% to 95% relative humidity (non-condensing)
- Dust and water resistance: IP-65 rating
- Hazardous location approvals CSA: Class I, Division 1, Groups A, B, C and D, T4 ATEX: 0575 II 2G Ex ia d IIC T4 Gb IECEx: Ex ia d IIC T4 Gb
- CE compliance (European Conformity) EMC Directive: 2004/108 / EC. R & TTE Directive: 1999/5 / EC. ATEX Directive: 94/9 / EC
- Performance testing compliant with MIL-STD-810G and 461F. LEL CSA C22.2 No. 152; ISA-12.13.01
- Languages: Arabic, Chinese, Czech, Danish, Dutch, English, French, German, Indonesian, Italian, Japanese, Korean, Norwegian, Polish, Portuguese, Russian, Spanish and Swedish
Choosing sensors and configuration
According to the manufacturer’s data sheet (DS-1068-11), the MultiRAE Pro has over 25 intelligent field-replaceable sensors that store calibration data and monitors up to six threat types at a time (a six-gas configuration needs a two-gas combination sensor). Sensor groups:
- Gamma radiation: 0 to 20,000 μRem/h, 1 cc CsI(Tl) scintillator with photodiode.
- PID for VOCs: 10.6 eV extended range 0-5,000 ppm (0.1 ppm) and ppb range 0-2,000 ppm (10 ppb).
- Combustible gas: catalytic LEL 0-100% LEL; NDIR 0-100% LEL or 0-100% Vol. methane; CO2 NDIR 0-50,000 ppm.
- Electrochemical: NH3, CO (several ranges, including H2-compensated and H2S combination), Cl2, ClO2, ethylene oxide, formaldehyde, HCN, H2S, methyl mercaptan, NO, NO2, O2, phosphine and SO2; liquid O2 is also available.
Operation and durability
- Built-in pump, average flow 250 cc/min, auto shutoff in low-flow conditions; 128 x 160 graphical display with backlight and an automatic screen flip.
- Alarms: multi-tone audible 95 dB at 30 cm, vibration, flashing red LEDs and on-screen indication; Man Down with pre-alarm and remote notification (wireless version).
- Battery: Li-ion about 12 h (recharge under 6 h), extended Li-ion about 18 h (recharge under 9 h), or an alkaline adapter with 4 x AA about 6 h (specifications are for non-wireless monitors).
- Continuous datalogging: six months for 5 sensors at one-minute intervals, running 24/7.
- IP-65; -20 to +50 °C; humidity 0 to 95% non-condensing; MIL-STD-810G and 461F compliant; 193 x 96.5 x 66 mm, 880 g.
- Manual calibration or automatic with AutoRAE 2; the manufacturer recommends calibrating the sensors on installation.
Approvals
Per the data sheet: CSA Class I Div. 1 Groups A, B, C, D, T4 and Class II Div. 1 Groups E, F, G; ATEX 0575 II 1G Ex ia IIC T4 Ga, and II 2G Ex ia d IIC T4 Gb with an IR sensor installed; IECEx Ex ia IIC T4 Ga (and Ex ia d IIC T4 Gb with an IR sensor installed); IECEx/ANZEx Ex ia IIC T4 Ga. The LEL sensor (model PGM-6248) is to CSA C22.2 No. 152 and ISA-12.13.01. Country-specific wireless approvals: ask the manufacturer.
What to send for a quote
- The gases and hazards to measure (VOC, LEL, O2, toxic gas, CO2, gamma) and their ranges.
- Wireless or non-wireless; battery option.
- Hazardous-area requirements and approvals needed.
- Whether you need AutoRAE 2 automatic calibration, and quantity.
CAD replies with a quote within 24 working hours of receiving the details.
TECHNICAL SPECIFICATIONS
Specifications of RAE Systems MultiRAE
| PARAMETER | VALUE |
|---|---|
| Model | MultiRAE Pro |
| Hazardous area approvals (standard) | CSA Class I, Div. 1, Groups A, B, C, D, T4; ATEX 0575 II 1G Ex ia IIC T4 Ga; IECEx Ex ia IIC T4 Ga |
| Hazardous area approvals (with IR sensor) | ATEX 2G Ex ia d IIC T4 Gb; IECEx Ex ia d IIC T4 Gb |
| Brand | RAE Systems |
| Dimensions | 7.6" H x 3.8" W x 2.6" D (193 x 96.5 x 66 mm) |
| Weight | 31 oz (880 g) |
| Sensors | More than 25 intelligent, field-replaceable sensors (gamma, PID, electrochemical, LEL, NDIR) |
| Operating temperature | -4 °F to 122 °F (-20 °C to 50 °C) |
| Humidity | 0% to 95% relative humidity (non-condensing) |
| Protection rating | IP-65 |
| Battery | Rechargeable Li-ion ~12 hours (charge < 6 hours); extended Li-ion ~18 hours (charge < 9 hours) |
| Sampling pump | Built-in, average flow rate 250 cc/min |
Specifications may vary with the ordered configuration. Contact a CAD engineer for sizing to your actual operating conditions.
FAQ
Frequently asked questions about CAD-SF-402
How many gases can the MultiRAE Pro measure at once?
Up to six threat types at a time; a six-gas configuration needs a two-gas combination sensor. The groups are gamma, VOC (PID), combustible (LEL / NDIR), CO2, toxic gases and O2.
How does the MultiRAE Pro differ from the ToxiRAE Pro?
The MultiRAE Pro has a sampling pump, more sensor types (gamma, PID, LEL, NDIR) and monitors several hazards at once. The ToxiRAE Pro is a compact personal monitor with diffusion sampling and electrochemical sensors.
How long does the battery last?
About 12 hours with the standard Li-ion pack, about 18 hours with the extended pack and about 6 hours with the AA alkaline adapter; the figures are for non-wireless monitors.
Can it be calibrated automatically?
Yes, manually or automatically with the AutoRAE 2 system, which runs fully automatic bump testing and calibration.
What do I need to send for a MultiRAE Pro quote?
The gases and hazards to measure with ranges, wireless or non-wireless, hazardous-area approvals and quantity. CAD replies within 24 working hours.