Honeywell RM7885A1015 Burner Controller
The Honeywell RM7885A1015 is a microprocessor-based 7800 SERIES integrated burner control, 120 Vac, with semi-automatic start through a Start switch, for single industrial burners firing gas, oil or combined fuel. Flame failure response time 0.8 or 3.0 seconds, used with a Q7800 subbase and a flame signal amplifier.
- Pilot control type Interrupted
- Power supply 120 Vac (+10, -15%), 50 Hz; 60 Hz (±10%)
- Modules used with the RM7800 Q7800A,B Universal Wiring Subbases. R7847, R7849, R7848, R7851, R7861 or Flame Signal Amplifier. R7886
- Ignition period (Start switch held) up to 15 minutes
- Genuine products
- Full CO/CQ
- VAT invoice
- Quote within 24 working hours
PRODUCT DESCRIPTION
Honeywell RM7885A1015 Burner Controller
Features:
- Factory-built-in system safety features.
- Semi-automatically fired: the operator pushes the Start switch to begin; the ignition period lasts while the switch is pushed, limited to 15 minutes (lockout if held 15 minutes).
- Pilot control type: Interrupted
- Supports a local or remote-mounted system display.
- Interchangeable plug-in flame signal amplifier.
- 5 LEDs show the step-by-step sequence while the system operates.
Specifications:
- Power supply: 120 Vac (+10, -15%), 50 Hz; 60 Hz (±10%)
- Modules used with the RM7800: Q7800A,B Universal Wiring Subbases. R7847,R7849, R7848, R7851, T7852, R7861 or Flame Signal Amplifier. R7886
- Ignition period (Start switch held): up to 15 minutes
- Combustion air flow check: Optional
- Dimensions (mm): 127 mm wide x 127 mm high x 133 mm deep with Q7800A module
- Subbase depth 155 mm with Q7800B module
- Approvals: CSA: Certified, File No. LR95329-3.
- Operating temperature: -40 C to +60 C
Semi-automatic start
According to Honeywell, the EC7885/RM7885 is an integrated burner control for semi-automatically fired gas, oil or combination-fuel single burner industrial applications. The system consists of a relay module, subbase and amplifier, and suits continuous, high-low or modulating firing.
- Torch ignition of a main burner or pilot, using an S445A Start-Stop Station or any conventional start-stop station.
- Electric ignition for a direct-ignition oil burner or pilot: electric ignition is maintained as long as the Start switch is pressed, up to 15 minutes.
- Normal sequence: Initiate 10 seconds; Standby and Run can be indefinite; Ignition is limited to 15 minutes. Lockout if the Start switch is held for 15 minutes.
Compatibility and installation
- A Q7800A1005 (panel mount) or Q7800B1003 (wall mount) subbase and a plug-in flame signal amplifier are required; the amplifier sets the flame failure response time of 0.8 or 3.0 seconds.
- Options: Keyboard Display Module (KDM), PC interface, Data ControlBus, remote display, first-out annunciator and Combustion System Manager software.
- Non-volatile memory keeps the history and sequence status through power loss; five LEDs show the sequence; maximum connected load 2000 VA, 15 A fast-blow fuse; operating temperature -40°C to +60°C.
Information to send for a quote
- The code RM7885A1015 and the quantity; the supply voltage (RM = 120 Vac, EC = 220-240 Vac).
- The fuel and ignition type (torch, electric, pilot) and the flame detector type, to select the amplifier and Q7800 subbase.
TECHNICAL SPECIFICATIONS
Specifications of Honeywell 7800 Series
| PARAMETER | VALUE |
|---|---|
| Model | RM7885A1015 |
| Pilot control type | Interrupted |
| Power supply | 120 Vac (+10, -15%), 50 Hz; 60 Hz (±10%) |
| Modules used with the RM7800 | Q7800A,B Universal Wiring Subbases. R7847, R7849, R7848, R7851, R7861 or Flame Signal Amplifier. R7886 |
| Ignition period (Start switch held) | up to 15 minutes |
| Combustion air flow check | Optional |
| Dimensions (mm) | 127 mm wide x 127 mm high x 133 mm deep with Q7800A module |
| Approvals | CSA: Certified, File No. LR95329-3. |
| Operating temperature | -40 C to +60 C |
| Brand | Honeywell |
| Origin | USA |
Specifications may vary with the ordered configuration. Contact a CAD engineer for sizing to your actual operating conditions.
FAQ
Frequently asked questions about CAD-TH-201
Does the RM7885A start fully automatically or semi-automatically?
Semi-automatically. According to Honeywell the burner is started with a Start switch (or the S445A station): the ignition period lasts while the button is pressed, up to 15 minutes, after which the system enters Run. If you need fully automatic control, talk to CAD about other models in the 7800 series.
How does the RM7885A differ from the EC7885A?
In supply voltage: the RM7885A uses 120 Vac and the EC7885A uses 220-240 Vac (both 50 or 60 Hz). The control functions are the same.
What accessories does the RM7885A need?
A Q7800A1005 or Q7800B1003 subbase and a plug-in flame signal amplifier, with a matching flame detector. A KDM keyboard display can be added for diagnostics.
What should I send CAD to quote an RM7885A1015?
Send the code RM7885A1015, quantity, fuel type, ignition type and flame detector. CAD quotes within 24 working hours.