Honeywell V5055 Safety Shutoff Valve
100% GENUINE
View larger
Honeywell V5055 Safety Shutoff Valve

Honeywell V5055 Safety Shutoff Valve

PRODUCT CODE
CAD-TH-220
BRAND
Honeywell

The Honeywell V5055 is a series of normally closed die-cast aluminium industrial gas valve bodies, 3/4 to 4 inch, for natural gas and LP gas; paired with a V4055, V4062 or V9055 fluid power actuator it forms a safety shutoff valve controlling gas to commercial and industrial burners.

  • For use with actuators V9055; V4055; V4062
  • Operating temperature -40 to +66 °C
  • Connection NPT threads for valves up to 3". Flanged connection for 4" valves
  • Maximum operating pressure differential (V4055A,D / V4062) 5 psi (340 mbar)
REQUEST A QUOTE DOWNLOAD DATASHEET (PDF)
  • Genuine products
  • Full CO/CQ
  • VAT invoice
  • Quote within 24 working hours

PRODUCT DESCRIPTION

Honeywell V5055 Safety Shutoff Valve

Specifications

  • For use with actuators: V9055; V4055; V4062
  • Operating temperature: -40 to +66 °C
  • Connection: NPT threads for valves up to 3″. Flanged connection for 4″ valves
  • Normally closed valve
  • Sizes 3/4″ – 4″
  • When used with V4055A,D or V4062: 5 psi (340 mbar);
  • When used with V4055B or E: 15 psi (1 bar)

Construction material

Cast aluminum

Approvals

  • V4055A,B,D,E, V4062, V9055: Listed, File No. MH1639 Guide No. YIOZ
  • V4055, V4062, V5097: Certified General listed File No. 158158, Class 3371 for USA and Canada

Models in the V5055 range

Model Characteristics
V5055A On-off valve
V5055B Characterized guide; with V4055, V4062 and V9055 actuators gives slow-opening, hi-lo-off and modulating functions
V5055C Same as V5055A but with a double seal; used with the V4055D actuator for a proof-of-closure switch
V5055D Same as V5055A, for high pressure applications
V5055E Same as V5055C, for high pressure applications
V5055F Same as V5055E, meets the intent of EN 161 leakage requirements

Sizes, connections and capacity

  • Seven NPT threaded sizes from 3/4 to 3 inch (BSP-PL threaded versions available); the 4 inch size (V5055A, B, C) has flange connections. Most models have a 1/4 inch upstream and downstream tap and plug; a yellow SHUT indicator on the valve stem shows the closed position.
  • Rated capacity at 1 in. w.c. (2.5 mbar) pressure drop, gas of specific gravity 0.64: 3/4 in 18.8 m³/h; 1 in 27.2; 1-1/4 in 39.8; 1-1/2 in 48.6; 2 in 102.5; 2-1/2 in 120.3; 3 in 148.1; 4 in 288.8 (V5055A) or 259.9 (V5055B, C) m³/h.
  • Weight about 1.8 kg (3/4-1-1/2 in), 3.6 kg (2 in), 5.0 kg (2-1/2 and 3 in), 12.7 kg (4 in).
  • Maximum rated pressure of the high-pressure V5055D, E: 5 bar (75 psi) in the 3/4-1-1/2 in sizes and 3 bar (45 psi) in the 2-3 in sizes; see the pressure table in Honeywell’s document for each valve and actuator combination.

Information to send for a quote

  • The valve body model (V5055A to F), valve size and thread type (NPT or BSP-PL) or flange.
  • The actuator to be paired (V4055, V4062, V9055), the control type (on-off, hi-lo-off, modulating) and the voltage.
  • The gas type, working pressure, required flow, and any need for a proof-of-closure switch or EN 161.

TECHNICAL SPECIFICATIONS

Specifications of Honeywell V5055 Safety Shutoff Valve

PARAMETER VALUE
Model V5055
For use with actuators V9055; V4055; V4062
Operating temperature -40 to +66 °C
Connection NPT threads for valves up to 3". Flanged connection for 4" valves
Maximum operating pressure differential (V4055A,D / V4062) 5 psi (340 mbar)
Maximum operating pressure differential (V4055B,E) 15 psi (1 bar)
UL approval (V4055A,B,D,E / V4062 / V9055) Listed, File No. MH1639, Guide No. YIOZ
CSA approval (V4055 / V4062 / V5097) Certified General listed File No. 158158, Class 3371 for USA and Canada
Valve type Normally closed
Size 3/4" - 4"
Body material Cast aluminum
Gas type Natural or liquefied petroleum (LP) only
Brand Honeywell

Specifications may vary with the ordered configuration. Contact a CAD engineer for sizing to your actual operating conditions.

FAQ

Frequently asked questions about CAD-TH-220

Does the V5055 open and close by itself or does it need an actuator?

The V5055 is the valve body; it must be paired with a V4055, V4062 or V9055 fluid power actuator to control the gas. Choose the actuator by the mode needed: on-off, hi-lo-off or modulating.

How do the V5055A and V5055B differ?

The V5055A is an on-off valve. The V5055B has a characterized guide and, with the V4055 (slow-opening), V4062 (hi-lo-off) or V9055 (modulating), regulates gas flow.

When should I choose V5055C, D, E or F?

C and E have a double seal and are used with V4055D/E actuators for a proof-of-closure switch; D and E are for high pressure; F meets the EN 161 leakage requirements. State your requirement when asking for a quote.

What should I send CAD to quote a V5055?

Send the valve body model, size and connection type, actuator and voltage, gas type, pressure and flow. CAD quotes within 24 working hours.