Honeywell V5055 Safety Shutoff Valve
The Honeywell V5055 is a series of normally closed die-cast aluminium industrial gas valve bodies, 3/4 to 4 inch, for natural gas and LP gas; paired with a V4055, V4062 or V9055 fluid power actuator it forms a safety shutoff valve controlling gas to commercial and industrial burners.
- For use with actuators V9055; V4055; V4062
- Operating temperature -40 to +66 °C
- Connection NPT threads for valves up to 3". Flanged connection for 4" valves
- Maximum operating pressure differential (V4055A,D / V4062) 5 psi (340 mbar)
- Genuine products
- Full CO/CQ
- VAT invoice
- Quote within 24 working hours
PRODUCT DESCRIPTION
Honeywell V5055 Safety Shutoff Valve
Specifications
- For use with actuators: V9055; V4055; V4062
- Operating temperature: -40 to +66 °C
- Connection: NPT threads for valves up to 3″. Flanged connection for 4″ valves
- Normally closed valve
- Sizes 3/4″ – 4″
- When used with V4055A,D or V4062: 5 psi (340 mbar);
- When used with V4055B or E: 15 psi (1 bar)
Construction material
Cast aluminum
Approvals
- V4055A,B,D,E, V4062, V9055: Listed, File No. MH1639 Guide No. YIOZ
- V4055, V4062, V5097: Certified General listed File No. 158158, Class 3371 for USA and Canada
Models in the V5055 range
| Model | Characteristics |
|---|---|
| V5055A | On-off valve |
| V5055B | Characterized guide; with V4055, V4062 and V9055 actuators gives slow-opening, hi-lo-off and modulating functions |
| V5055C | Same as V5055A but with a double seal; used with the V4055D actuator for a proof-of-closure switch |
| V5055D | Same as V5055A, for high pressure applications |
| V5055E | Same as V5055C, for high pressure applications |
| V5055F | Same as V5055E, meets the intent of EN 161 leakage requirements |
Sizes, connections and capacity
- Seven NPT threaded sizes from 3/4 to 3 inch (BSP-PL threaded versions available); the 4 inch size (V5055A, B, C) has flange connections. Most models have a 1/4 inch upstream and downstream tap and plug; a yellow SHUT indicator on the valve stem shows the closed position.
- Rated capacity at 1 in. w.c. (2.5 mbar) pressure drop, gas of specific gravity 0.64: 3/4 in 18.8 m³/h; 1 in 27.2; 1-1/4 in 39.8; 1-1/2 in 48.6; 2 in 102.5; 2-1/2 in 120.3; 3 in 148.1; 4 in 288.8 (V5055A) or 259.9 (V5055B, C) m³/h.
- Weight about 1.8 kg (3/4-1-1/2 in), 3.6 kg (2 in), 5.0 kg (2-1/2 and 3 in), 12.7 kg (4 in).
- Maximum rated pressure of the high-pressure V5055D, E: 5 bar (75 psi) in the 3/4-1-1/2 in sizes and 3 bar (45 psi) in the 2-3 in sizes; see the pressure table in Honeywell’s document for each valve and actuator combination.
Information to send for a quote
- The valve body model (V5055A to F), valve size and thread type (NPT or BSP-PL) or flange.
- The actuator to be paired (V4055, V4062, V9055), the control type (on-off, hi-lo-off, modulating) and the voltage.
- The gas type, working pressure, required flow, and any need for a proof-of-closure switch or EN 161.
TECHNICAL SPECIFICATIONS
Specifications of Honeywell V5055 Safety Shutoff Valve
| PARAMETER | VALUE |
|---|---|
| Model | V5055 |
| For use with actuators | V9055; V4055; V4062 |
| Operating temperature | -40 to +66 °C |
| Connection | NPT threads for valves up to 3". Flanged connection for 4" valves |
| Maximum operating pressure differential (V4055A,D / V4062) | 5 psi (340 mbar) |
| Maximum operating pressure differential (V4055B,E) | 15 psi (1 bar) |
| UL approval (V4055A,B,D,E / V4062 / V9055) | Listed, File No. MH1639, Guide No. YIOZ |
| CSA approval (V4055 / V4062 / V5097) | Certified General listed File No. 158158, Class 3371 for USA and Canada |
| Valve type | Normally closed |
| Size | 3/4" - 4" |
| Body material | Cast aluminum |
| Gas type | Natural or liquefied petroleum (LP) only |
| Brand | Honeywell |
Specifications may vary with the ordered configuration. Contact a CAD engineer for sizing to your actual operating conditions.
FAQ
Frequently asked questions about CAD-TH-220
Does the V5055 open and close by itself or does it need an actuator?
The V5055 is the valve body; it must be paired with a V4055, V4062 or V9055 fluid power actuator to control the gas. Choose the actuator by the mode needed: on-off, hi-lo-off or modulating.
How do the V5055A and V5055B differ?
The V5055A is an on-off valve. The V5055B has a characterized guide and, with the V4055 (slow-opening), V4062 (hi-lo-off) or V9055 (modulating), regulates gas flow.
When should I choose V5055C, D, E or F?
C and E have a double seal and are used with V4055D/E actuators for a proof-of-closure switch; D and E are for high pressure; F meets the EN 161 leakage requirements. State your requirement when asking for a quote.
What should I send CAD to quote a V5055?
Send the valve body model, size and connection type, actuator and voltage, gas type, pressure and flow. CAD quotes within 24 working hours.