Maxon KINEDIZER® LE Burner
Maxon KINEDIZER LE is a high-capacity low-NOx gas burner: nine sizes from 1-1/2" to 16", up to 75 MMBtu/h (21,960 kW), turndown up to 20:1, chamber up to 1,100 °C, combustion air preheated up to 350 °C. For oxidizers, kilns, dryers and waste incineration.
- Fuel Natural gas, propane or other gaseous fuels
- Capacity Up to 75 MMBtu/h
- Turndown ratio Up to 20:1
- Maximum combustion chamber temperature 2000 °F
- Genuine products
- Full CO/CQ
- VAT invoice
- Quote within 24 working hours
PRODUCT DESCRIPTION
Maxon KINEDIZER® LE Burner
The KINEDIZER® LE is a nozzle-mix, medium-velocity burner design using advanced mixing technology. The burner produces low emissions at very low excess air. It fires natural gas, propane or other gaseous fuels. Combustion air is supplied by an external blower. Precise air/fuel ratio control is achieved with a MAXON MICRO-RATIO® valve or SMARTLINK® technology. Combustion air can range from 21% down to 17% O2 if vitiated, and from ambient temperature up to 660°F (800°F maximum) preheated on request. Maximum chamber temperature is 2000°F. Turndown ratio is up to 20:1.
- Low NOx emissions with low excess oxygen
- Rugged design for oxidizers, process heaters, furnaces, kilns, dryers, waste incineration and other high-temperature applications
- Available in many capacity sizes, each with a turndown ratio of up to 20:1
- Fires natural gas, propane or other fuel gases
- Excellent stirring and mixing with medium-velocity discharge
- Accepts preheated combustion air
- Capacity up to 75 MMBtu/h
- Multiple supply voltages: 1 phase, 3 phase 220V, 380V (50Hz, 60Hz)
Applications
According to Maxon, the KINEDIZER LE has a rugged design suited to oxidizers and incinerators, process heaters, kilns, furnaces, dryers and other high temperature applications with low to ultra-low emissions. In low temperature air heating applications (below 760 °C) a user-supplied discharge sleeve is needed; contact Maxon for the recommended size.
Construction
- Nozzle-mix, medium-velocity design; reinforced refractory block, steel burner body and nozzle.
- Combustion air is supplied by an external blower; accurate air and fuel modulation with the MAXON MICRO-RATIO valve or SMARTLINK technology.
- Combustion air can range from 21% down to 17% O2 if preheated, and from ambient up to 350 °C (max. 430 °C on request); maximum chamber temperature 1,100 °C; turndown up to 20:1.
- Low NOx is reached with 20–30% excess air at high fire; adjusted for on-ratio operation the burner gives low CO and high thermal efficiency; flue gas recirculation improves emissions and efficiency further.
Maximum capacity by size
| Size | 1-1/2″ | 3″ | 4″ | 6″ | 8″ | 10″ | 12″ | 14″ | 16″ |
|---|---|---|---|---|---|---|---|---|---|
| Max. capacity @ n=1.3, low NOx (kW, HHV) | 160 | 700 | 1,350 | 2,870 | 4,630 | 7,120 | 9,955 | 16,100 | 21,960 |
Manufacturer note: pressures and data are indicative; actual pressures depend on air humidity, altitude, type of fuel and gas quality. Contact Maxon for application details.
Information to send with a quote request
So that CAD can quote within 24 working hours, please send:
- Required capacity (kW or MMBtu/h) and burner size (1-1/2″ to 16″).
- Fuel (natural gas, propane or other) and the gas pressure available.
- Chamber temperature, combustion air temperature (preheated or not) and the O2 content of the air.
- The application (furnace, dryer, oxidizer…), NOx / emission requirements and the ratio control system (MICRO-RATIO, SMARTLINK).
TECHNICAL SPECIFICATIONS
Specifications of Maxon KINEDIZER® LE
| PARAMETER | VALUE |
|---|---|
| Model | KINEDIZER® LE |
| Fuel | Natural gas, propane or other gaseous fuels |
| Capacity | Up to 75 MMBtu/h |
| Turndown ratio | Up to 20:1 |
| Maximum combustion chamber temperature | 2000 °F |
| Preheated combustion air temperature | From ambient up to 660 °F (800 °F maximum on request) |
| Burner sizes | 1.5", 3", 4", 6", 8", 10", 12", 14", 16" |
| Supply voltages | 1 phase, 3 phase 220V, 380V (50Hz, 60Hz) |
| Brand | Maxon |
| Origin | USA |
Specifications may vary with the ordered configuration. Contact a CAD engineer for sizing to your actual operating conditions.
FAQ
Frequently asked questions about CAD-TH-211
Which sizes and capacities does the Maxon KINEDIZER LE come in?
Nine sizes from 1-1/2" to 16", with maximum capacity (n=1.3, low NOx, HHV) from 160 kW to 21,960 kW (about 75 MMBtu/h), each with turndown up to 20:1.
Which fuels does the KINEDIZER LE burn, and how is the combustion air supplied?
Natural gas, propane or other fuel gases. Combustion air comes from an external blower and can be preheated up to 350 °C (max. 430 °C on request); the ratio is controlled by a MICRO-RATIO valve or SMARTLINK.
Is the KINEDIZER LE a low-emission burner?
According to Maxon it gives low NOx with about 20–30% excess air at high fire, and low CO and high efficiency when adjusted on-ratio; flue gas recirculation improves it further. Send your specific emission requirement and CAD will pass it to the manufacturer.
What furnaces and applications is the KINEDIZER LE for?
Oxidizers and incinerators, process heaters, kilns, furnaces, dryers and other high temperature applications; maximum chamber temperature 1,100 °C.
What do I send to get a quote for the KINEDIZER LE?
Send the capacity, fuel, chamber and combustion air temperature, application and ratio control system. CAD quotes within 24 working hours.