Honeywell Searchpoint Optima Plus 2108N4000N Fixed Gas Detector
100% GENUINE
View larger
Honeywell Searchpoint Optima Plus 2108N4000N Fixed Gas Detector

Honeywell Searchpoint Optima Plus 2108N4000N Fixed Gas Detector

PRODUCT CODE
CAD-SF-432
BRAND
Honeywell
PRODUCT LINE
Searchpoint Optima Plus

2108N4000N is the Honeywell Searchpoint Optima Plus point infrared hydrocarbon gas detector, 0-100% LEL, 4-20mA, IP66/67, ATEX/IECEx, SIL 2; configuration: hydrocarbon calibration, with dust barrier, weather housing, deluge/heat shade.

  • Brand Honeywell
  • Series Searchpoint Optima Plus
  • Type Point infrared hydrocarbon gas detector
  • Configuration of this code Hydrocarbon calibration, with dust barrier, weather housing, deluge/heat shade
REQUEST A QUOTE DOWNLOAD DATASHEET (PDF)
  • Genuine products
  • Full CO/CQ
  • VAT invoice
  • Quote within 24 working hours

PRODUCT DESCRIPTION

Honeywell Searchpoint Optima Plus 2108N4000N Fixed Gas Detector

2108N4000N is the Honeywell Searchpoint Optima Plus point infrared hydrocarbon gas detector, 0-100% LEL range, 4-20mA autosensing sink or source output, 316 stainless steel housing, IP66/67. Approved to ATEX, IECEx and UL/CSA, with IEC61508 SIL 2 functional safety. Configuration of this code: hydrocarbon calibration, with dust barrier, weather housing, deluge/heat shade.

Per the datasheet, the infrared principle gives fail-to-safe operation, a fast response, immunity to catalytic poisons and operation in inert atmospheres, with no moving parts. Over 100 gas and vapour calibrations are available; ask CAD for the list of gases.

How does 2108N4000N differ from 2108N4000H, 2108N4010H?

2108N4000N differs from 2108N4000H and 2108N4010H in HART output and the remote gassing cell. 2108N4000N: hydrocarbon calibration, with dust barrier, weather housing, deluge/heat shade. 2108N4000H: as 2108N4000N, plus HART output. 2108N4010H: as 2108N4000H, plus a remote gassing cell. The measuring, electrical and approval data below is the Searchpoint Optima Plus datasheet table shared by all three codes.

2108N4000N specifications

  • Brand: Honeywell
  • Series: Searchpoint Optima Plus
  • Type: Point infrared hydrocarbon gas detector
  • Configuration of this code: Hydrocarbon calibration, with dust barrier, weather housing, deluge/heat shade
  • Measuring range: 0-100% LEL; wide selection of hydrocarbon gas and vapour calibrations; different measuring ranges and solvent calibrations available for specialist applications
  • Signal output: 4-20mA autosensing sink or source
  • Inhibit: 1-3mA (default 2mA)
  • Warning: 0-6mA (default 3mA *)
  • Fault: 0mA (HART units adjustable to 1mA)
  • Over range: 20-21.5mA (default 21mA)
  • Digital output: Optional multidrop Modbus RS485 (via XNX); optional HART over 4-20mA output (HART version 7)
  • Material: 316 stainless steel
  • Weight: 1.6kg
  • Accuracy: Optima Plus (hydrocarbon): baseline < ±1% FSD, 50% FSD < ±2% FSD; Optima Plus (ethylene): baseline < ±2% FSD, 50% FSD < ±3% FSD
  • Repeatability: < ±2% FSD at 50% FSD
  • Linearity: < 5% FSD
  • Response time: T50 < 3 seconds, T90 < 4 seconds (methane)
  • Operating and certified temperature: -40°C to +65°C; CU-TR-EX (Russia) approval, XTC version: -60°C to +65°C
  • Long-term stability (as defined in EN 60079-29-1): Baseline: methane 100 %LEL range ≤ ±2 %FSD, ethylene 100 %LEL range ≤ ±4 %FSD; 50 %FSD: methane 100 %LEL range ≤ ±4 %FSD, ethylene 100 %LEL range ≤ ±5 %FSD
  • Drift over temperature range (-40°C to 65°C): Baseline ≤ ±2 %FSD; 50 %FSD: methane 100 %LEL range ≤ ±0.131 %FSD per °C, ethylene 100 %LEL range ≤ ±0.078 %FSD per °C
  • Variation with pressure: 0.1% (of reading) per mbar
  • Power supply: 18-32Vdc (24Vdc nominal), < 4.5W max
  • Environmental protection: IP66/67
  • Diagnostics (and re-calibration): Via certified Hand-held Interrogator, XNX or optional HART communications
  • Safety approvals: ATEX: Baseefa13ATEX0296X, II 2 GD Ex d op is IIC Gb Ex tb IIIC Db, T96°C (Tamb -40°C to +65°C), T86°C (Tamb -40°C to +55°C), IP66/67; UL/CSA: Class 1, Div 1, groups B, C and D (-40°C to +65°C); IECEx: II 2 GD Ex d op is IIC Gb Ex tb IIIC Db, T86°C (Tamb -40°C to +55°C) or T96°C (Tamb -40°C to +65°C), IP66/67; CU-TR-EX (Russian Customs Union), XTC version: 1Ex d op is IIC T5/T4 Gb X (Tamb -60°C to +65°C)
  • Performance approvals: EN 60079-29-1 (BVS 03 ATEX G 016 X), CSA C22.2 152, FM ANSI/ISA-12.13.01, Russian Pattern Approval (Metrology) – XTC version (refer to manual for full information)
  • Functional safety: IEC61508 Safety Integrity Level 2 (SIL 2)
  • EMC compliance: EN 50270:2006
  • Software: EN 50271:2010
  • Marine approvals: Marine Equipment Directive (MED), type approvals from DNV, BV, ABS, Lloyd’s Register
  • Note: * For ATEX compliance the warning value should not be set between 3 and 5mA

Applications

The Honeywell datasheet lists typical applications for the Searchpoint Optima Plus: environments that may suffer from catalytic bead poisons or inhibitors, or harsh conditions that call for longer intervals between routine maintenance, for example offshore oil and gas platforms, floating production storage and offloading (FPSO) vessels, tankers, onshore oil and gas terminals, refineries, LNG / LPG bottling plants, gas compressor / metering stations, gas turbine power plants and solvent printing and coating plants.

TECHNICAL SPECIFICATIONS

Specifications of Honeywell Searchpoint Optima Plus

PARAMETER VALUE
Model 2108N4000N
Brand Honeywell
Series Searchpoint Optima Plus
Type Point infrared hydrocarbon gas detector
Configuration of this code Hydrocarbon calibration, with dust barrier, weather housing, deluge/heat shade
Measuring range 0-100% LEL; wide selection of hydrocarbon gas and vapour calibrations; different measuring ranges and solvent calibrations available for specialist applications
Signal output 4-20mA autosensing sink or source
Inhibit 1-3mA (default 2mA)
Warning 0-6mA (default 3mA *)
Fault 0mA (HART units adjustable to 1mA)
Over range 20-21.5mA (default 21mA)
Digital output Optional multidrop Modbus RS485 (via XNX); optional HART over 4-20mA output (HART version 7)
Material 316 stainless steel
Weight 1.6kg
Accuracy Optima Plus (hydrocarbon): baseline < ±1% FSD, 50% FSD < ±2% FSD; Optima Plus (ethylene): baseline < ±2% FSD, 50% FSD < ±3% FSD
Repeatability < ±2% FSD at 50% FSD
Linearity < 5% FSD
Response time T50 < 3 seconds, T90 < 4 seconds (methane)
Operating and certified temperature -40°C to +65°C; CU-TR-EX (Russia) approval, XTC version: -60°C to +65°C
Long-term stability (as defined in EN 60079-29-1) Baseline: methane 100 %LEL range ≤ ±2 %FSD, ethylene 100 %LEL range ≤ ±4 %FSD; 50 %FSD: methane 100 %LEL range ≤ ±4 %FSD, ethylene 100 %LEL range ≤ ±5 %FSD
Drift over temperature range (-40°C to 65°C) Baseline ≤ ±2 %FSD; 50 %FSD: methane 100 %LEL range ≤ ±0.131 %FSD per °C, ethylene 100 %LEL range ≤ ±0.078 %FSD per °C
Variation with pressure 0.1% (of reading) per mbar
Power supply 18-32Vdc (24Vdc nominal), < 4.5W max
Environmental protection IP66/67
Diagnostics (and re-calibration) Via certified Hand-held Interrogator, XNX or optional HART communications
Safety approvals ATEX: Baseefa13ATEX0296X, II 2 GD Ex d op is IIC Gb Ex tb IIIC Db, T96°C (Tamb -40°C to +65°C), T86°C (Tamb -40°C to +55°C), IP66/67; UL/CSA: Class 1, Div 1, groups B, C and D (-40°C to +65°C); IECEx: II 2 GD Ex d op is IIC Gb Ex tb IIIC Db, T86°C (Tamb -40°C to +55°C) or T96°C (Tamb -40°C to +65°C), IP66/67; CU-TR-EX (Russian Customs Union), XTC version: 1Ex d op is IIC T5/T4 Gb X (Tamb -60°C to +65°C)
Performance approvals EN 60079-29-1 (BVS 03 ATEX G 016 X), CSA C22.2 152, FM ANSI/ISA-12.13.01, Russian Pattern Approval (Metrology) - XTC version (refer to manual for full information)
Functional safety IEC61508 Safety Integrity Level 2 (SIL 2)
EMC compliance EN 50270:2006
Software EN 50271:2010
Marine approvals Marine Equipment Directive (MED), type approvals from DNV, BV, ABS, Lloyd’s Register
Note * For ATEX compliance the warning value should not be set between 3 and 5mA

Specifications may vary with the ordered configuration. Contact a CAD engineer for sizing to your actual operating conditions.

OTHER CODES IN THE RANGE

Same series

FAQ

Frequently asked questions about CAD-SF-432

How does 2108N4000N differ from 2108N4000H, 2108N4010H?

They differ in HART output and the remote gassing cell. 2108N4000N: hydrocarbon calibration, with dust barrier, weather housing, deluge/heat shade. 2108N4000H: as 2108N4000N, plus HART output. 2108N4010H: as 2108N4000H, plus a remote gassing cell.

What measuring range and output does 2108N4000N have?

0-100% LEL with a wide selection of hydrocarbon gas and vapour calibrations; 4-20mA autosensing sink or source output; 18-32Vdc supply (24Vdc nominal), < 4.5W max; response T50 < 3 seconds, T90 < 4 seconds (methane).

What approvals does 2108N4000N hold?

ATEX (Baseefa13ATEX0296X, II 2 GD Ex d op is IIC Gb Ex tb IIIC Db), IECEx, UL/CSA Class 1 Div 1 groups B, C and D, IEC61508 SIL 2 functional safety, performance to EN 60079-29-1; IP66/67.

Used this product? Write a review