Honeywell Searchpoint Optima Plus 2108N4010H Fixed Gas Detector
2108N4010H is the Honeywell Searchpoint Optima Plus point infrared hydrocarbon gas detector, 0-100% LEL, 4-20mA, IP66/67, ATEX/IECEx, SIL 2; configuration: hydrocarbon calibration, with dust barrier, weather housing, deluge/heat shade, HART output, including remote gassing cell.
- Brand Honeywell
- Series Searchpoint Optima Plus
- Type Point infrared hydrocarbon gas detector
- Configuration of this code Hydrocarbon calibration, with dust barrier, weather housing, deluge/heat shade, HART output, including remote gassing cell
- Genuine products
- Full CO/CQ
- VAT invoice
- Quote within 24 working hours
PRODUCT DESCRIPTION
Honeywell Searchpoint Optima Plus 2108N4010H Fixed Gas Detector
2108N4010H is the Honeywell Searchpoint Optima Plus point infrared hydrocarbon gas detector, 0-100% LEL range, 4-20mA autosensing sink or source output, 316 stainless steel housing, IP66/67. Approved to ATEX, IECEx and UL/CSA, with IEC61508 SIL 2 functional safety. Configuration of this code: hydrocarbon calibration, with dust barrier, weather housing, deluge/heat shade, HART output, including remote gassing cell.
Per the datasheet, the infrared principle gives fail-to-safe operation, a fast response, immunity to catalytic poisons and operation in inert atmospheres, with no moving parts. Over 100 gas and vapour calibrations are available; ask CAD for the list of gases.
How does 2108N4010H differ from 2108N4000N, 2108N4000H?
2108N4010H differs from 2108N4000N and 2108N4000H in HART output and the remote gassing cell. 2108N4000N: hydrocarbon calibration, with dust barrier, weather housing, deluge/heat shade. 2108N4000H: as 2108N4000N, plus HART output. 2108N4010H: as 2108N4000H, plus a remote gassing cell. The measuring, electrical and approval data below is the Searchpoint Optima Plus datasheet table shared by all three codes. HART (Highway Addressable Remote Transducer) superimposes a digital signal on the existing 4-20mA cable, so no extra cabling is needed; the datasheet lists functions such as viewing gas readings and diagnostics, bump test, mA loop and gas calibration, simulating alarm / fault / warning, changing the target gas and configuring thresholds. The remote gassing cell is factory-fitted within the optical path and allows functional test gas to be injected remotely to validate the detector.
2108N4010H specifications
- Brand: Honeywell
- Series: Searchpoint Optima Plus
- Type: Point infrared hydrocarbon gas detector
- Configuration of this code: Hydrocarbon calibration, with dust barrier, weather housing, deluge/heat shade, HART output, including remote gassing cell
- Measuring range: 0-100% LEL; wide selection of hydrocarbon gas and vapour calibrations; different measuring ranges and solvent calibrations available for specialist applications
- Signal output: 4-20mA autosensing sink or source
- Inhibit: 1-3mA (default 2mA)
- Warning: 0-6mA (default 3mA *)
- Fault: 0mA (HART units adjustable to 1mA)
- Over range: 20-21.5mA (default 21mA)
- Digital output: Optional multidrop Modbus RS485 (via XNX); optional HART over 4-20mA output (HART version 7)
- Material: 316 stainless steel
- Weight: 1.6kg
- Accuracy: Optima Plus (hydrocarbon): baseline < ±1% FSD, 50% FSD < ±2% FSD; Optima Plus (ethylene): baseline < ±2% FSD, 50% FSD < ±3% FSD
- Repeatability: < ±2% FSD at 50% FSD
- Linearity: < 5% FSD
- Response time: T50 < 3 seconds, T90 < 4 seconds (methane)
- Operating and certified temperature: -40°C to +65°C; CU-TR-EX (Russia) approval, XTC version: -60°C to +65°C
- Long-term stability (as defined in EN 60079-29-1): Baseline: methane 100 %LEL range ≤ ±2 %FSD, ethylene 100 %LEL range ≤ ±4 %FSD; 50 %FSD: methane 100 %LEL range ≤ ±4 %FSD, ethylene 100 %LEL range ≤ ±5 %FSD
- Drift over temperature range (-40°C to 65°C): Baseline ≤ ±2 %FSD; 50 %FSD: methane 100 %LEL range ≤ ±0.131 %FSD per °C, ethylene 100 %LEL range ≤ ±0.078 %FSD per °C
- Variation with pressure: 0.1% (of reading) per mbar
- Power supply: 18-32Vdc (24Vdc nominal), < 4.5W max
- Environmental protection: IP66/67
- Diagnostics (and re-calibration): Via certified Hand-held Interrogator, XNX or optional HART communications
- Safety approvals: ATEX: Baseefa13ATEX0296X, II 2 GD Ex d op is IIC Gb Ex tb IIIC Db, T96°C (Tamb -40°C to +65°C), T86°C (Tamb -40°C to +55°C), IP66/67; UL/CSA: Class 1, Div 1, groups B, C and D (-40°C to +65°C); IECEx: II 2 GD Ex d op is IIC Gb Ex tb IIIC Db, T86°C (Tamb -40°C to +55°C) or T96°C (Tamb -40°C to +65°C), IP66/67; CU-TR-EX (Russian Customs Union), XTC version: 1Ex d op is IIC T5/T4 Gb X (Tamb -60°C to +65°C)
- Performance approvals: EN 60079-29-1 (BVS 03 ATEX G 016 X), CSA C22.2 152, FM ANSI/ISA-12.13.01, Russian Pattern Approval (Metrology) – XTC version (refer to manual for full information)
- Functional safety: IEC61508 Safety Integrity Level 2 (SIL 2)
- EMC compliance: EN 50270:2006
- Software: EN 50271:2010
- Marine approvals: Marine Equipment Directive (MED), type approvals from DNV, BV, ABS, Lloyd’s Register
- Note: * For ATEX compliance the warning value should not be set between 3 and 5mA
Applications
The Honeywell datasheet lists typical applications for the Searchpoint Optima Plus: environments that may suffer from catalytic bead poisons or inhibitors, or harsh conditions that call for longer intervals between routine maintenance, for example offshore oil and gas platforms, floating production storage and offloading (FPSO) vessels, tankers, onshore oil and gas terminals, refineries, LNG / LPG bottling plants, gas compressor / metering stations, gas turbine power plants and solvent printing and coating plants.
TECHNICAL SPECIFICATIONS
Specifications of Honeywell Searchpoint Optima Plus 2108N4010H Fixed Gas Detector
| PARAMETER | VALUE |
|---|---|
| Model | 2108N4010H |
| Brand | Honeywell |
| Series | Searchpoint Optima Plus |
| Type | Point infrared hydrocarbon gas detector |
| Configuration of this code | Hydrocarbon calibration, with dust barrier, weather housing, deluge/heat shade, HART output, including remote gassing cell |
| Measuring range | 0-100% LEL; wide selection of hydrocarbon gas and vapour calibrations; different measuring ranges and solvent calibrations available for specialist applications |
| Signal output | 4-20mA autosensing sink or source |
| Inhibit | 1-3mA (default 2mA) |
| Warning | 0-6mA (default 3mA *) |
| Fault | 0mA (HART units adjustable to 1mA) |
| Over range | 20-21.5mA (default 21mA) |
| Digital output | Optional multidrop Modbus RS485 (via XNX); optional HART over 4-20mA output (HART version 7) |
| Material | 316 stainless steel |
| Weight | 1.6kg |
| Accuracy | Optima Plus (hydrocarbon): baseline < ±1% FSD, 50% FSD < ±2% FSD; Optima Plus (ethylene): baseline < ±2% FSD, 50% FSD < ±3% FSD |
| Repeatability | < ±2% FSD at 50% FSD |
| Linearity | < 5% FSD |
| Response time | T50 < 3 seconds, T90 < 4 seconds (methane) |
| Operating and certified temperature | -40°C to +65°C; CU-TR-EX (Russia) approval, XTC version: -60°C to +65°C |
| Long-term stability (as defined in EN 60079-29-1) | Baseline: methane 100 %LEL range ≤ ±2 %FSD, ethylene 100 %LEL range ≤ ±4 %FSD; 50 %FSD: methane 100 %LEL range ≤ ±4 %FSD, ethylene 100 %LEL range ≤ ±5 %FSD |
| Drift over temperature range (-40°C to 65°C) | Baseline ≤ ±2 %FSD; 50 %FSD: methane 100 %LEL range ≤ ±0.131 %FSD per °C, ethylene 100 %LEL range ≤ ±0.078 %FSD per °C |
| Variation with pressure | 0.1% (of reading) per mbar |
| Power supply | 18-32Vdc (24Vdc nominal), < 4.5W max |
| Environmental protection | IP66/67 |
| Diagnostics (and re-calibration) | Via certified Hand-held Interrogator, XNX or optional HART communications |
| Safety approvals | ATEX: Baseefa13ATEX0296X, II 2 GD Ex d op is IIC Gb Ex tb IIIC Db, T96°C (Tamb -40°C to +65°C), T86°C (Tamb -40°C to +55°C), IP66/67; UL/CSA: Class 1, Div 1, groups B, C and D (-40°C to +65°C); IECEx: II 2 GD Ex d op is IIC Gb Ex tb IIIC Db, T86°C (Tamb -40°C to +55°C) or T96°C (Tamb -40°C to +65°C), IP66/67; CU-TR-EX (Russian Customs Union), XTC version: 1Ex d op is IIC T5/T4 Gb X (Tamb -60°C to +65°C) |
| Performance approvals | EN 60079-29-1 (BVS 03 ATEX G 016 X), CSA C22.2 152, FM ANSI/ISA-12.13.01, Russian Pattern Approval (Metrology) - XTC version (refer to manual for full information) |
| Functional safety | IEC61508 Safety Integrity Level 2 (SIL 2) |
| EMC compliance | EN 50270:2006 |
| Software | EN 50271:2010 |
| Marine approvals | Marine Equipment Directive (MED), type approvals from DNV, BV, ABS, Lloyd’s Register |
| Note | * For ATEX compliance the warning value should not be set between 3 and 5mA |
Specifications may vary with the ordered configuration. Contact a CAD engineer for sizing to your actual operating conditions.
OTHER CODES IN THE RANGE
Same series
FAQ
Frequently asked questions about 2108N4010H
How does 2108N4010H differ from 2108N4000N, 2108N4000H?
They differ in HART output and the remote gassing cell. 2108N4000N: hydrocarbon calibration, with dust barrier, weather housing, deluge/heat shade. 2108N4000H: as 2108N4000N, plus HART output. 2108N4010H: as 2108N4000H, plus a remote gassing cell.
What measuring range and output does 2108N4010H have?
0-100% LEL with a wide selection of hydrocarbon gas and vapour calibrations; 4-20mA autosensing sink or source output; 18-32Vdc supply (24Vdc nominal), < 4.5W max; response T50 < 3 seconds, T90 < 4 seconds (methane).
What approvals does 2108N4010H hold?
ATEX (Baseefa13ATEX0296X, II 2 GD Ex d op is IIC Gb Ex tb IIIC Db), IECEx, UL/CSA Class 1 Div 1 groups B, C and D, IEC61508 SIL 2 functional safety, performance to EN 60079-29-1; IP66/67.