Honeywell Sensepoint XCD Fixed Gas Detector (Flammable, Toxic, Oxygen)
Sensepoint XCD is the Honeywell fixed gas detector range for flammable, toxic and oxygen gases: 4-20mA, 3 relays, optional MODBUS, ATEX/IECEx/UL, IP66, plug-in sensors.
- Brand Honeywell
- Series Sensepoint XCD
- Type Fixed gas detector for flammable, toxic and oxygen gases (transmitter with plug-in sensor)
- Use 3 wire, 4-20mA and RS485 MODBUS output fixed point detector with in-built alarm and fault relays for the protection of personnel and plant from flammable, toxic and oxygen hazards; transmitter with local display, fully configurable via non-intrusive magnetic switch interface; wide range of sensors available
- Genuine products
- Full CO/CQ
- VAT invoice
- Quote within 24 working hours
PRODUCT DESCRIPTION
Honeywell Sensepoint XCD Fixed Gas Detector (Flammable, Toxic, Oxygen)
Sensepoint XCD is the Honeywell range of fixed gas detectors for flammable (catalytic or infrared), toxic and oxygen gases in potentially explosive atmospheres, indoors and outdoors. The detector is a 3-wire 4-20mA device (sink or source) with 3 built-in relays (2 alarm, 1 fault), optional MODBUS, a tri-colour LCD that shows status from a distance and magnetic-switch configuration without opening the cover. Explosion-proof aluminium or 316 stainless steel housing, IP66 as standard; plug-in sensors are quick to replace without a hot work permit in hazardous areas.
The datasheet lists ATEX, IECEx, UL/c-UL, KTL, PA, GB and CCCF approvals. Each transmitter auto-recognises any sensor in its family: the mV family (catalytic and infrared), the electrochemical (EC) family (CO, H2S, NO2, H2) and the oxygen (O2) family.
How does Sensepoint XCD differ from Sensepoint XCD RFD and Sensepoint XCD RTD?
Sensepoint XCD is the complete detector with the sensor plugged into the base of the transmitter. Sensepoint XCD RFD is the transmitter for remotely mounted flammable gas sensors, with a range adjustable from 0-100%LEL down to 0-20%LEL. Sensepoint XCD RTD is the transmitter for Sensepoint toxic and oxygen sensors, mounted directly or remotely. The four codes SPXCDALMFX, SPXCDALMRX, SPXCDALMO1 and SPXCDALMG1 in the order-code table below are configurations of this range (flammable catalytic, methane IR, oxygen, hydrogen; painted marine grade aluminium housing, M20 entry).
Sensepoint XCD specifications
- Brand: Honeywell
- Series: Sensepoint XCD
- Type: Fixed gas detector for flammable, toxic and oxygen gases (transmitter with plug-in sensor)
- Use: 3 wire, 4-20mA and RS485 MODBUS output fixed point detector with in-built alarm and fault relays for the protection of personnel and plant from flammable, toxic and oxygen hazards; transmitter with local display, fully configurable via non-intrusive magnetic switch interface; wide range of sensors available
- Input voltage range: 16 to 32VDC (24VDC nominal) for ATEX/IECEx/AP versions; 12 to 32VDC (24VDC nominal) for UL/CSA version
- Max power consumption: Depends on the sensor type: electrochemical cells = 3.7W, IR = 3.7W, catalytic = 4.9W; maximum inrush current = 800mA at 24VDC
- Current output: Sink or source. ≥0.0<1.0mA: fault; 2.0mA or 4.0mA (17.4mA): inhibit (during configuration / user settings); 4.0mA to 20.0mA: normal gas measurement; 22.0mA: maximum over range
- Terminals: 15 x screw terminals suitable for wire diameter 0.5mm2 to 2.5mm2 (20AWG to 13AWG)
- Relays: 3 x 5A@250VAC; selectable normally open or normally closed (switch) and energised / de-energised (programmable). Alarm relays default normally open / de-energised; fault relay default normally open / energised
- Communication: RS485, MODBUS RTU (optional)
- Material: Housing: epoxy painted aluminium alloy LM25 or 316 stainless steel; sensor: 316 stainless steel; weather protection: plastic
- Weight (approx): Aluminium alloy LM25: 2.0kg (4.4lbs); 316 stainless steel: 5.0kg (11lbs)
- Mounting: Integral mounting plate with 4 x mounting holes suitable for M8 bolts; optional pipe mounting kit for horizontal or vertical pipe Ø1.5 to 3″ (2″ nominal)
- Entries: European ATEX/IECEx versions: 2 x M20 cable entries; North American UL/c-UL versions: 2 x ¾”NPT conduit entries (blanking plug supplied, to be sealed to maintain the IP rating if only 1 entry is used)
- IP rating: IP66 in accordance with EN60529:1992
- Certified temperature range: -40°C to +75°C (-40°F to +167°F); the display may become illegible below -20°C but the detector continues gas monitoring
- Humidity / pressure / storage: Operating humidity continuous 20-90%RH (non-condensing), intermittent 10-99%RH; operating pressure 90-110kPa (EC toxic sensors); storage -25°C to +65°C (-13°F to 131°F)
- Certification: European: ATEX II 2 GD Ex d IIC Gb T6 (Ta -40°C to +65°C) T5 (Ta -40°C to +75°C) Ex tb IIIC T85°C Db IP66 T100°C (Ta -40°C to +75°C); international: IECEx equivalent; China: GB Ex d IIC T4 GB3836.1&2 -2000, PA, CCCF; Korea: KTL Ex d IIC T6 (-40°C to +65°C); North America: UL/c-UL Class I, Division 1, Groups B, C and D, Class I, Division 2, Groups B, C & D, Class II, Division 1, Groups E, F & G, Class II, Division 2, Groups F & G (-40°C to +65°C); EMC: EN50270:2006, EN6100-6-4:2007; performance: ATEX, EN60079-29-1:2007 (flammable), EN45544 (toxic), EN50104 (oxygen), EN50271, CSA C22.2-152
- Standard supply: Integral wall mounting plate, 2 x M20 cable entries (ATEX/IECEx) or 2 x ¾”NPT conduit entries (UL/cUL), 1 x plug, Allen key for locking screw, weatherproof cap, operating magnet, sensor cartridge with retainer, quick start guide and instruction manual CD; each unit is supplied with a calibration and test certificate
Gases, ranges and sensor performance
From the datasheet table “Detectable Gases and XCD Sensor Performance”: selectable full scale range, default range, T90 response time (seconds), accuracy and default alarm points A1 / A2 (sensor operating temperature, steps and cal point are in the datasheet).
| Gas, sensor type | Selectable full scale range | Default range | T90 (secs) | Accuracy | Default alarm A1 / A2 |
|---|---|---|---|---|---|
| Oxygen (O2), electrochemical | 25.0%Vol only | 25.0%Vol | < 30 | < ±0.5%Vol | 19.5%Vol falling / 23.5%Vol rising |
| Hydrogen sulphide (H2S), electrochemical | 10.0 to 100.0ppm | 50.0ppm | < 50 | < ±1ppm | 10ppm rising / 20ppm rising |
| Carbon monoxide (CO), electrochemical | 100 to 1,000ppm | 300ppm | < 30 | < ±6ppm | 100ppm rising / 200ppm rising |
| Hydrogen (H2), electrochemical | 1,000ppm only | 1,000ppm | < 65 | < ±25ppm | 200ppm rising / 400ppm rising |
| Nitrogen dioxide (NO2), electrochemical | 10.0 to 50.0ppm | 10.0ppm | < 40 | < ±3ppm or ±20% | 0.7ppm rising / 2.0ppm rising |
| Flammable 1 to 8, catalytic bead | 20 to 100%LEL | 100%LEL | < 25 | < ±1.5%LEL | 20%LEL rising / 40%LEL rising |
| Methane, infrared (IR) | 20 to 100%LEL | 100%LEL | < 30 | < ±1.5%LEL | 20%LEL rising / 40%LEL rising |
| Propane, infrared (IR) | 20 to 100%LEL | 100%LEL | < 30 | < ±1.5%LEL | 20%LEL rising / 40%LEL rising |
| Carbon dioxide (CO2), infrared (IR) | 2.00%Vol only | 2.00%Vol | < 30 | < ±0.04%Vol | 0.40%Vol rising / 0.80%Vol rising |
How to read the order code
- Certification: A = ATEX/IECEx (datasheet: ATEX/IECEx/KTL/PA and GB); U = UL/CSA
- Enclosure material: L = LM25 aluminium; S = stainless steel
- Entry: M = M20 (ATEX/IECEx); N = 3/4″NPT (UL/CSA)
- Sensor type: F = flammable catalytic bead; R = flammable IR methane %LEL; P = flammable IR propane; O = oxygen; H = hydrogen sulphide; C = carbon monoxide; G = hydrogen; N = nitrogen dioxide; B = carbon dioxide IR
- Gas range: X = user adjustable; 1 = fixed
- M suffix: add M to the end of the code for the optional MODBUS output (for example SPXCDALMFXM)
Order codes
The table lists the Sensepoint XCD detector codes and the spare sensor cartridges (codes starting SPXCDXS) from the CAD document; the four codes SPXCDALMFX, SPXCDALMRX, SPXCDALMO1 and SPXCDALMG1 also have their own pages.
| Order code | Description |
|---|---|
| SPXCDALMFX | ATEX/IECEX & AP approved SP XCD Flammable CAT, 0-100%LEL (20,0 to 100.0%LEL) with Painted Marine Grade Al, M20 Entry |
| SPXCDALMRX | ATEX/IECEX & AP approved SP XCD CH4(Methane) IR, 0-100%LEL (20,0 to 100.0%LEL) with Painted Marine Grade Al, M20 Entry |
| SPXCDALMPX | ATEX/IECEX & AP approved SP XCD C3H8(Propane) IR, 0-100%LEL (20,0 to 100.0%LEL) with Painted Marine Grade Al, M20 Entry |
| SPXCDALMO1 | ATEX/IECEX & AP approved SP XCD Oxygen, 25.0%/Vol with Painted Marine Grade Al, M20 Entry |
| SPXCDALMHX | ATEX/IECEX & AP approved SP XCD Hydrogen Sulphide 0-50ppm (10.0 to 100.0ppm) with Painted Marine Grade Al, M20 Entry |
| SPXCDALMCX | ATEX/IECEX & AP approved SP XCD Carbon Monoxide 0-300ppm (100 to 1000ppm) with Painted Marine Grade Al, M20 Entry |
| SPXCDALMG1 | ATEX/IECEX & AP approved SP XCD Hydrogen 0-1000ppm with Painted Marine Grade Al, M20 Entry |
| SPXCDALMNX | ATEX/IECEX & AP approved SP XCD Nitrogen Dioxide 0-50ppm with Painted Marine Grade Al, M20 Entry |
| SPXCDALMB1 | ATEX/IECEX & AP approved SP XCD CO2(Carbon Dioxide) IR 0-2%VOL with Painted Marine Grade Al, M20 Entry |
| SPXCDALMB2 | ATEX/IECEX & AP approved SP XCD CO2(Carbon Dioxide) IR 0-5%VOL with Painted Marine Grade Al, M20 Entry |
| SPXCDASMFX | ATEX/IECEX & AP approved SP XCD Flammable CAT 0-100%LEL (20,0 to 100.0%LEL) with SS316, M20 Entry |
| SPXCDASMRX | ATEX/IECEX & AP approved SP XCD CH4(Methane) IR 0-100%LEL (20,0 to 100.0%LEL) with SS316, M20 Entry |
| SPXCDASMPX | ATEX/IECEX & AP approved SP XCD C3H8(Propane) IR 0-100%LEL (20,0 to 100.0%LEL) with SS316, M20 Entry |
| SPXCDASMO1 | ATEX/IECEX & AP approved SP XCD Oxygen 25.0%/Vol with SS316, M20 Entry |
| SPXCDASMHX | ATEX/IECEX & AP approved SP XCD Hydrogen Sulphide 0-50ppm (10.0 to 100.0ppm) with SS316, M20 Entry |
| SPXCDASMCX | ATEX/IECEX & AP approved SP XCD Carbon Monoxide 0-300ppm (100 to 1000ppm) with SS316, M20 Entry |
| SPXCDASMG1 | ATEX/IECEX & AP approved SP XCD Hydrogen 0-1000ppm with SS316, M20 Entry |
| SPXCDASMNX | ATEX/IECEX & AP approved SP XCD Nitrogen Dioxide 0-50ppm with SS316, M20 Entry |
| SPXCDASMB1 | ATEX/IECEX & AP approved SP XCD CO2(Carbon Dioxide) IR 0-2%VOL with SS316, M20 Entry |
| SPXCDASMB2 | ATEX/IECEX & AP approved SP XCD CO2(Carbon Dioxide) IR 0-5%VOL with SS316, M20 Entry |
| SPXCDALMFXM | ATEX/IECEX & AP approved SP XCD Flammable CAT, 0-100%LEL (20,0 to 100.0%LEL) with Painted Marine Grade Al, M20 Entry, With Modbus |
| SPXCDALMRXM | ATEX/IECEX & AP approved SP XCD CH4(Methane) IR, 0-100%LEL (20,0 to 100.0%LEL) with Painted Marine Grade Al, M20 Entry, With Modbus |
| SPXCDALMPXM | ATEX/IECEX & AP approved SP XCD C3H8(Propane) IR, 0-100%LEL (20,0 to 100.0%LEL) with Painted Marine Grade Al, M20 Entry, With Modbus |
| SPXCDALMO1M | ATEX/IECEX & AP approved SP XCD Oxygen, 25.0%/Vol with Painted Marine Grade Al, M20 Entry, With Modbus |
| SPXCDALMHXM | ATEX/IECEX & AP approved SP XCD Hydrogen Sulphide 0-50ppm (10.0 to 100.0ppm) with Painted Marine Grade Al, M20 Entry, With Modbus |
| SPXCDALMCXM | ATEX/IECEX & AP approved SP XCD Carbon Monoxide 0-300ppm (100 to 1000ppm) with Painted Marine Grade Al, M20 Entry, With Modbus |
| SPXCDALMG1M | ATEX/IECEX & AP approved SP XCD Hydrogen 0-1000ppm with Painted Marine Grade Al, M20 Entry, With Modbus |
| SPXCDALMNXM | ATEX/IECEX & AP approved SP XCD Nitrogen Dioxide 0-50ppm with Painted Marine Grade Al, M20 Entry, With Modbus |
| SPXCDALMB1M | ATEX/IECEX & AP approved SP XCD CO2(Carbon Dioxide) IR 0-2%VOL with Painted Marine Grade Al, M20 Entry, With Modbus |
| SPXCDALMB2M | ATEX/IECEX & AP approved SP XCD CO2(Carbon Dioxide) IR 0-5%VOL with Painted Marine Grade Al, M20 Entry, With Modbus |
| SPXCDASMFXM | ATEX/IECEX & AP approved SP XCD Flammable CAT 0-100%LEL (20,0 to 100.0%LEL) with SS316, M20 Entry, With Modbus |
| SPXCDASMRXM | ATEX/IECEX & AP approved SP XCD CH4(Methane) IR 0-100%LEL (20,0 to 100.0%LEL) with SS316, M20 Entry, With Modbus |
| SPXCDASMPXM | ATEX/IECEX & AP approved SP XCD C3H8(Propane) IR 0-100%LEL (20,0 to 100.0%LEL) with SS316, M20 Entry, with Modbus |
| SPXCDASMO1M | ATEX/IECEX & AP approved SP XCD Oxygen 25.0%/Vol with SS316, M20 Entry, With Modbus |
| SPXCDASMHXM | ATEX/IECEX & AP approved SP XCD Hydrogen Sulphide 0-50ppm (10.0 to 100.0ppm) with SS316, M20 Entry, With Modbus |
| SPXCDASMCXM | ATEX/IECEX & AP approved SP XCD Carbon Monoxide 0-300ppm (100 to 1000ppm) with SS316, M20 Entry, With Modbus |
| SPXCDASMG1M | ATEX/IECEX & AP approved SP XCD Hydrogen 0-1000ppm with SS316, M20 Entry, With Modbus |
| SPXCDASMNXM | ATEX/IECEX & AP approved SP XCD Nitrogen Dioxide 0-50ppm with SS316, M20 Entry, With Modbus |
| SPXCDASMB1M | ATEX/IECEX & AP approved SP XCD CO2(Carbon Dioxide) IR 0-2%VOL with SS316, M20 Entry, With Modbus |
| SPXCDASMB2M | ATEX/IECEX & AP approved SP XCD CO2(Carbon Dioxide) IR 0-5%VOL with SS316, M20 Entry, With Modbus |
| SPXCDULNFX | UL approved SP XCD Flammable CAT 0-100%LEL (20,0 to 100.0%LEL, 10%LEL) with Painted Marine Grade Al, 3/4″NPT Entry |
| SPXCDULNRX | UL approved SP XCD CH4(Methane) IR 0-100%LEL (20,0 to 100.0%LEL, 10%LEL) with Painted Marine Grade Al, 3/4″NPT Entry |
| SPXCDULNPX | UL approved SP XCD C3H8(Propane) IR 0-100%LEL (20,0 to 100.0%LEL, 10%LEL) with Painted Marine Grade Al, 3/4″NPT Entry |
| SPXCDULNO1 | UL approved SP XCD Oxygen 25.0%/Vol with Painted Marine Grade Al, 3/4″NPT Entry |
| SPXCDULNHX | UL approved SP XCD Hydrogen Sulfide 0-50ppm (10.0 to 100.0ppm, 1ppm) with Painted Marine Grade Al, 3/4″NPT Entry |
| SPXCDULNCX | UL approved SP XCD Carbon Monoxide 0-300ppm (100 to 1000ppm, 100ppm) with Painted Marine Grade Al, 3/4″NPT Entry |
| SPXCDULNG1 | UL approved SP XCD Hydrogen 0-1000ppm with Painted Marine Grade Al, 3/4″NPT Entry |
| SPXCDULNNX | UL approved SP XCD Nitrogen Dioxide 0-50ppm with Painted Marine Grade Al, 3/4″NPT Entry |
| SPXCDULNB1 | UL approved SP XCD Carbon Dioxide IR 0-2%VOL with Painted Marine Grade Al, 3/4″NPT Entry |
| SPXCDULNB2 | UL approved SP XCD Carbon Dioxide IR 0-5%VOL with Painted Marine Grade Al, 3/4″NPT Entry |
| SPXCDUSNFX | UL approved SP XCD Flammable CAT 0-100%LEL (20,0 to 100.0%LEL, 10%LEL) with SS316, 3/4″NPT Entry |
| SPXCDUSNRX | UL approved SP XCD CH4(Methane) IR 0-100%LEL (20,0 to 100.0%LEL, 10%LEL) with SS316, 3/4″NPT Entry |
| SPXCDUSNPX | UL approved SP XCD C3H8(Propane) IR 0-100%LEL (20,0 to 100.0%LEL, 10%LEL) with SS316, 3/4″NPT Entry |
| SPXCDUSNO1 | UL approved SP XCD Oxygen 25.0%/Vol with SS316, 3/4″NPT Entry |
| SPXCDUSNHX | UL approved SP XCD Hydrogen Sulfide 0-50ppm (10.0 to 100.0ppm, 1ppm) with SS316, 3/4″NPT Entry |
| SPXCDUSNCX | UL approved SP XCD Carbon Monoxide 0-300ppm (100 to 1000ppm, 100ppm) with SS316, 3/4″NPT Entry |
| SPXCDUSNG1 | UL approved SP XCD Hydrogen 0-1000ppm with SS316, 3/4″NPT Entry |
| SPXCDUSNNX | UL approved SP XCD Nitrogen Dioxide 0-50ppm with SS316, 3/4″NPT Entry |
| SPXCDUSNB1 | UL approved SP XCD Carbon Dioxide IR 0-2%VOL with SS316, 3/4″NPT Entry |
| SPXCDUSNB2 | UL approved SP XCD Carbon Dioxide IR 0-5%VOL with SS316, 3/4″NPT Entry |
| SPXCDXSFXSS | Flammable CAT 0-100%LEL (20,0 to 100.0%LEL) |
| SPXCDXSRXSS | CH4(Methane) IR 0-100%LEL (20,0 to 100.0%LEL) |
| SPXCDXSPXSS | C3H8 (Propane) IR 0-100%LEL (20,0 to 100.0%LEL) |
| SPXCDXSO1SS | Oxygen 25.0%/Vol only |
| SPXCDXSHXSS | Hydrogen Sulfide 0-50ppm (10.0 to 100.0ppm) |
| SPXCDXSCXSS | Carbon Monoxide 0-300ppm (100 to 1000ppm) |
| SPXCDXSG1SS | Hydrogen 0-1000ppm only |
| SPXCDXSNXSS | Nitrogen Dioxide 10-50ppm (10.0 to 50.0ppm) |
| SPXCDXSB1SS | Carbon Dioxide IR 0-2%VOL only |
| SPXCDXSB2SS | Carbon Dioxide IR 0-5%VOL only |
Applications
The Honeywell datasheet lists typical applications: industrial manufacturing facilities, power plants, waste water facilities, utilities, food and beverage production, refineries and chemical plants, onshore oil and gas terminals, production platforms, and exploration and drilling.
TECHNICAL SPECIFICATIONS
Specifications of Honeywell Sensepoint XCD Fixed Gas Detector (Flammable, Toxic, Oxygen)
| PARAMETER | VALUE |
|---|---|
| Model | Sensepoint XCD |
| Brand | Honeywell |
| Series | Sensepoint XCD |
| Type | Fixed gas detector for flammable, toxic and oxygen gases (transmitter with plug-in sensor) |
| Use | 3 wire, 4-20mA and RS485 MODBUS output fixed point detector with in-built alarm and fault relays for the protection of personnel and plant from flammable, toxic and oxygen hazards; transmitter with local display, fully configurable via non-intrusive magnetic switch interface; wide range of sensors available |
| Input voltage range | 16 to 32VDC (24VDC nominal) for ATEX/IECEx/AP versions; 12 to 32VDC (24VDC nominal) for UL/CSA version |
| Max power consumption | Depends on the sensor type: electrochemical cells = 3.7W, IR = 3.7W, catalytic = 4.9W; maximum inrush current = 800mA at 24VDC |
| Current output | Sink or source. ≥0.0<1.0mA: fault; 2.0mA or 4.0mA (17.4mA): inhibit (during configuration / user settings); 4.0mA to 20.0mA: normal gas measurement; 22.0mA: maximum over range |
| Terminals | 15 x screw terminals suitable for wire diameter 0.5mm2 to 2.5mm2 (20AWG to 13AWG) |
| Relays | 3 x 5A@250VAC; selectable normally open or normally closed (switch) and energised / de-energised (programmable). Alarm relays default normally open / de-energised; fault relay default normally open / energised |
| Communication | RS485, MODBUS RTU (optional) |
| Material | Housing: epoxy painted aluminium alloy LM25 or 316 stainless steel; sensor: 316 stainless steel; weather protection: plastic |
| Weight (approx) | Aluminium alloy LM25: 2.0kg (4.4lbs); 316 stainless steel: 5.0kg (11lbs) |
| Mounting | Integral mounting plate with 4 x mounting holes suitable for M8 bolts; optional pipe mounting kit for horizontal or vertical pipe Ø1.5 to 3" (2" nominal) |
| Entries | European ATEX/IECEx versions: 2 x M20 cable entries; North American UL/c-UL versions: 2 x ¾"NPT conduit entries (blanking plug supplied, to be sealed to maintain the IP rating if only 1 entry is used) |
| IP rating | IP66 in accordance with EN60529:1992 |
| Certified temperature range | -40°C to +75°C (-40°F to +167°F); the display may become illegible below -20°C but the detector continues gas monitoring |
| Humidity / pressure / storage | Operating humidity continuous 20-90%RH (non-condensing), intermittent 10-99%RH; operating pressure 90-110kPa (EC toxic sensors); storage -25°C to +65°C (-13°F to 131°F) |
| Certification | European: ATEX II 2 GD Ex d IIC Gb T6 (Ta -40°C to +65°C) T5 (Ta -40°C to +75°C) Ex tb IIIC T85°C Db IP66 T100°C (Ta -40°C to +75°C); international: IECEx equivalent; China: GB Ex d IIC T4 GB3836.1&2 -2000, PA, CCCF; Korea: KTL Ex d IIC T6 (-40°C to +65°C); North America: UL/c-UL Class I, Division 1, Groups B, C and D, Class I, Division 2, Groups B, C & D, Class II, Division 1, Groups E, F & G, Class II, Division 2, Groups F & G (-40°C to +65°C); EMC: EN50270:2006, EN6100-6-4:2007; performance: ATEX, EN60079-29-1:2007 (flammable), EN45544 (toxic), EN50104 (oxygen), EN50271, CSA C22.2-152 |
| Standard supply | Integral wall mounting plate, 2 x M20 cable entries (ATEX/IECEx) or 2 x ¾"NPT conduit entries (UL/cUL), 1 x plug, Allen key for locking screw, weatherproof cap, operating magnet, sensor cartridge with retainer, quick start guide and instruction manual CD; each unit is supplied with a calibration and test certificate |
Specifications may vary with the ordered configuration. Contact a CAD engineer for sizing to your actual operating conditions.
OTHER CODES IN THE RANGE
Same series
- Sensepoint XCD RFD Honeywell Sensepoint XCD RFD Flammable Gas Transmitter (Remote Sensor)
- SPXCDALMFX Honeywell Sensepoint XCD SPXCDALMFX Fixed Gas Detector (Flammable, Catalytic)
- SPXCDALMG1 Honeywell Sensepoint XCD SPXCDALMG1 Fixed Gas Detector (Hydrogen)
- SPXCDALMO1 Honeywell Sensepoint XCD SPXCDALMO1 Fixed Gas Detector (Oxygen)
- SPXCDALMRX Honeywell Sensepoint XCD SPXCDALMRX Fixed Gas Detector (Methane, Infrared)
FAQ
Frequently asked questions about Sensepoint XCD
How does Sensepoint XCD differ from Sensepoint XCD RFD and Sensepoint XCD RTD?
Sensepoint XCD is the complete detector with the sensor plugged into the base of the transmitter. Sensepoint XCD RFD is the transmitter for remotely mounted flammable gas sensors; Sensepoint XCD RTD is the transmitter for Sensepoint toxic and oxygen sensors.
Which gases can Sensepoint XCD measure?
Flammable gas (catalytic 0-100%LEL, infrared methane, propane), electrochemical toxic gases (H2S, CO, H2, NO2), oxygen (O2) and infrared carbon dioxide (CO2 2.00%Vol).
How do I pick the order code and the Modbus version?
The code reads in order: certification (A or U), enclosure (L aluminium or S stainless steel), entry (M or N), sensor type and gas range. Add M to the end of the code for the optional MODBUS output, for example SPXCDALMFXM.