Honeywell Sensepoint XCD SPXCDALMRX Fixed Gas Detector (Methane, Infrared)
SPXCDALMRX is a Honeywell Sensepoint XCD methane (CH4) infrared (IR) detector, 0-100%LEL range (20,0 to 100.0%LEL selectable), 4-20mA, 3 relays, painted marine grade aluminium housing, M20 entry, ATEX/IECEx & AP, IP66.
- Brand Honeywell
- Series Sensepoint XCD
- Type Fixed gas detector (transmitter with plug-in sensor)
- Approval of this code ATEX/IECEx & AP
- Genuine products
- Full CO/CQ
- VAT invoice
- Quote within 24 working hours
PRODUCT DESCRIPTION
Honeywell Sensepoint XCD SPXCDALMRX Fixed Gas Detector (Methane, Infrared)
SPXCDALMRX is a Honeywell Sensepoint XCD fixed gas detector: methane (CH4) infrared (IR) detector, 0-100%LEL range (20,0 to 100.0%LEL selectable). Painted marine grade aluminium housing, M20 entry, ATEX/IECEx & AP approval, IP66. A 3-wire 4-20mA device with 3 relays (2 alarm, 1 fault), a local display and configuration by magnetic switch without opening the cover.
How does SPXCDALMRX differ from SPXCDALMFX, SPXCDALMO1 and SPXCDALMG1?
SPXCDALMRX differs from SPXCDALMFX, SPXCDALMO1 and SPXCDALMG1 in the gas, sensor and range; same Sensepoint XCD transmitter, the same painted marine grade aluminium housing, M20 entry and ATEX/IECEx & AP approval. SPXCDALMFX: flammable gas detector with a catalytic bead (Cat) sensor, 0-100%LEL range (20,0 to 100.0%LEL selectable). SPXCDALMRX: methane (CH4) infrared (IR) detector, 0-100%LEL range (20,0 to 100.0%LEL selectable). SPXCDALMO1: oxygen (O2) detector, fixed 25.0%Vol range. SPXCDALMG1: hydrogen (H2) detector, 0-1000ppm range. The optional Modbus version is the code with an M suffix (for example SPXCDALMFXM), listed in the Sensepoint XCD order-code table.
SPXCDALMRX specifications
- Brand: Honeywell
- Series: Sensepoint XCD
- Type: Fixed gas detector (transmitter with plug-in sensor)
- Approval of this code: ATEX/IECEx & AP
- Housing and entry of this code: Painted Marine Grade Al, M20 entry
- Gas: Methane (CH4)
- Sensor technology: Infrared (IR)
- User selectable full scale range: 20.0 to 100.0%LEL
- Default range: 100%LEL
- Steps: 10%LEL
- User selectable cal gas range: 30 to 70% of selected full scale range
- Default cal point: 50%LEL
- Response time (T90): < 30 secs
- Accuracy: < ±1.5%LEL
- Sensor operating temperature: -20°C (-4°F) to 50°C (122°F)
- Default alarm A1 / A2: 20%LEL rising / 40%LEL rising
- Lowest limits: Lowest detectable limit 5%LEL; lowest alarm level 10%LEL
- Use: 3 wire, 4-20mA and RS485 MODBUS output fixed point detector with in-built alarm and fault relays for the protection of personnel and plant from flammable, toxic and oxygen hazards; incorporates a transmitter with local display, fully configurable via non-intrusive magnetic switch interface
- Input voltage range: 12 to 32VDC (24VDC nominal)
- Max power consumption: Depends on the sensor type: electrochemical cells = 3.7W, IR = 3.7W, catalytic = 4.9W; maximum inrush current = 800mA at 24VDC
- Current output: Sink or source
- Relays: 3 x 5A@250VAC; selectable normally open or normally closed (switch) and energised / de-energised (programmable). Alarm relays default normally open / de-energised; fault relay default normally open / energised
- Communication: RS485, MODBUS RTU
- Housing material: Epoxy painted aluminium alloy or 316 stainless steel (this code: painted marine grade aluminium); sensor: 316 stainless steel
- Weight (approx): Aluminium alloy: 4.4 lbs (2.0 kg); 316 stainless steel: 11 lbs (5.0 kg)
- Mounting: Integral mounting plate with 4 x mounting holes suitable for M8 bolts; optional pipe mounting kit for horizontal or vertical pipe Ø1.5 to 3″ (2″ nominal)
- Cable entries: 2 x M20 (ATEX/IECEx versions)
- IP rating: IP66 in accordance with EN60529:1992
- Certified temperature range: -40°C to +65°C (-40°F to +149°F)
- European approval: ATEX Ex II 2 GD Ex d IIC Gb T6 (Ta -40°C to +65°C) Ex tb IIIC T85°C Db IP66
- International approval: IEC Ex d IIC Gb T6 (Ta -40°C to +65°C) Ex tb IIIC T85°C Db IP66
- EMC: CE: EN50270:2006, EN6100-6-4:2007
- Performance approvals: UL508; CSA 22.2 No. 152 (flammable gases, excludes infrared sensors); ATEX, IEC/EN60079-29-1:2007, EN45544, EN50104, EN50271; China: PA Pattern Measurement (for transmitter and toxic gas sensors), “CCCF” Shenyang for flammable (fire dept approval)
Applications
The Honeywell datasheet lists typical Sensepoint XCD applications: industrial manufacturing facilities, power plants, waste water facilities, utilities, food and beverage production, refineries and chemical plants, onshore oil and gas terminals, production platforms, and exploration and drilling.
TECHNICAL SPECIFICATIONS
Specifications of Honeywell Sensepoint XCD SPXCDALMRX Fixed Gas Detector (Methane, Infrared)
| PARAMETER | VALUE |
|---|---|
| Model | SPXCDALMRX |
| Brand | Honeywell |
| Series | Sensepoint XCD |
| Type | Fixed gas detector (transmitter with plug-in sensor) |
| Approval of this code | ATEX/IECEx & AP |
| Housing and entry of this code | Painted Marine Grade Al, M20 entry |
| Gas | Methane (CH4) |
| Sensor technology | Infrared (IR) |
| User selectable full scale range | 20.0 to 100.0%LEL |
| Default range | 100%LEL |
| Steps | 10%LEL |
| User selectable cal gas range | 30 to 70% of selected full scale range |
| Default cal point | 50%LEL |
| Response time (T90) | < 30 secs |
| Accuracy | < ±1.5%LEL |
| Sensor operating temperature | -20°C (-4°F) to 50°C (122°F) |
| Default alarm A1 / A2 | 20%LEL rising / 40%LEL rising |
| Lowest limits | Lowest detectable limit 5%LEL; lowest alarm level 10%LEL |
| Use | 3 wire, 4-20mA and RS485 MODBUS output fixed point detector with in-built alarm and fault relays for the protection of personnel and plant from flammable, toxic and oxygen hazards; incorporates a transmitter with local display, fully configurable via non-intrusive magnetic switch interface |
| Input voltage range | 12 to 32VDC (24VDC nominal) |
| Max power consumption | Depends on the sensor type: electrochemical cells = 3.7W, IR = 3.7W, catalytic = 4.9W; maximum inrush current = 800mA at 24VDC |
| Current output | Sink or source |
| Relays | 3 x 5A@250VAC; selectable normally open or normally closed (switch) and energised / de-energised (programmable). Alarm relays default normally open / de-energised; fault relay default normally open / energised |
| Communication | RS485, MODBUS RTU |
| Housing material | Epoxy painted aluminium alloy or 316 stainless steel (this code: painted marine grade aluminium); sensor: 316 stainless steel |
| Weight (approx) | Aluminium alloy: 4.4 lbs (2.0 kg); 316 stainless steel: 11 lbs (5.0 kg) |
| Mounting | Integral mounting plate with 4 x mounting holes suitable for M8 bolts; optional pipe mounting kit for horizontal or vertical pipe Ø1.5 to 3" (2" nominal) |
| Cable entries | 2 x M20 (ATEX/IECEx versions) |
| IP rating | IP66 in accordance with EN60529:1992 |
| Certified temperature range | -40°C to +65°C (-40°F to +149°F) |
| European approval | ATEX Ex II 2 GD Ex d IIC Gb T6 (Ta -40°C to +65°C) Ex tb IIIC T85°C Db IP66 |
| International approval | IEC Ex d IIC Gb T6 (Ta -40°C to +65°C) Ex tb IIIC T85°C Db IP66 |
| EMC | CE: EN50270:2006, EN6100-6-4:2007 |
| Performance approvals | UL508; CSA 22.2 No. 152 (flammable gases, excludes infrared sensors); ATEX, IEC/EN60079-29-1:2007, EN45544, EN50104, EN50271; China: PA Pattern Measurement (for transmitter and toxic gas sensors), "CCCF" Shenyang for flammable (fire dept approval) |
Specifications may vary with the ordered configuration. Contact a CAD engineer for sizing to your actual operating conditions.
OTHER CODES IN THE RANGE
Same series
- Sensepoint XCD Honeywell Sensepoint XCD Fixed Gas Detector (Flammable, Toxic, Oxygen)
- Sensepoint XCD RFD Honeywell Sensepoint XCD RFD Flammable Gas Transmitter (Remote Sensor)
- SPXCDALMFX Honeywell Sensepoint XCD SPXCDALMFX Fixed Gas Detector (Flammable, Catalytic)
- SPXCDALMG1 Honeywell Sensepoint XCD SPXCDALMG1 Fixed Gas Detector (Hydrogen)
- SPXCDALMO1 Honeywell Sensepoint XCD SPXCDALMO1 Fixed Gas Detector (Oxygen)
FAQ
Frequently asked questions about SPXCDALMRX
How does SPXCDALMRX differ from SPXCDALMFX, SPXCDALMO1 and SPXCDALMG1?
Same Sensepoint XCD transmitter; they differ in gas, sensor and range: SPXCDALMFX: flammable gas detector with a catalytic bead (Cat) sensor, 0-100%LEL range (20,0 to 100.0%LEL selectable). SPXCDALMRX: methane (CH4) infrared (IR) detector, 0-100%LEL range (20,0 to 100.0%LEL selectable). SPXCDALMO1: oxygen (O2) detector, fixed 25.0%Vol range. SPXCDALMG1: hydrogen (H2) detector, 0-1000ppm range.
What gas does SPXCDALMRX measure and over what range?
Methane (CH4) infrared (IR), 0-100%LEL (20,0 to 100.0%LEL selectable), T90 < 30 secs, accuracy < ±1.5%LEL.
What approvals and protection rating does SPXCDALMRX have?
ATEX/IECEx & AP approval: ATEX Ex II 2 GD Ex d IIC Gb T6 (Ta -40°C to +65°C) Ex tb IIIC T85°C Db IP66, IEC Ex d IIC Gb T6; IP66 rating; certified temperature range -40°C to +65°C.