Honeywell HON 200 Gas Pressure Regulator
100% GENUINE
View larger
Honeywell HON 200 Gas Pressure Regulator

Honeywell HON 200 Gas Pressure Regulator

PRODUCT CODE
CAD-FL-141
BRAND
Honeywell

HON 200 small gas pressure regulator is used for controlling outlet and differential pressure (flow control), and superimposed electric control loops. It is ideal for deployment at offtake stations in gas transmission, industrial facilities and low-load lines in larger gas pressure regulating stations.

  • Max. admissible pressure PS 100 bar (depending on type of flange)
  • Max. inlet pressure pu max up to 100 bar
  • Outlet pressure range Wd 0.02 bar up to 90 bar
  • Min. pressure drop approx. 1 bar, others on enquiry
Product description Last updated 09/2026

PRODUCT DESCRIPTION

Honeywell HON 200 Gas Pressure Regulator

HON 200 is a pilot-operated gas pressure regulator according to DIN EN 334, with CE registration according to PED.

Applications include:

  • Device for offtake stations in gas transmission, industrial facilities and low-load lines in larger gas pressure regulating stations
  • Optional outdoor type
  • Suitable for large turn down ratios
  • Installation of different valve seat diameters is possible
  • Straightforward, easy-to-maintain design
  • Suitable for controlling outlet and inlet pressure, outlet and differential pressure (flow control), and superimposed electric control loops
  • Fail-close function
  • Suitable for non-aggressive gases and other gases on enquiry.

Other features include:

  • Max. admissible pressure PS: 100 bar (depending on type of flange)
  • Max. inlet pressure pu max: up to 100 bar
  • Outlet pressure range Wd: 0.02 bar up to 90 bar
  • Min. pressure drop approx.: 1 bar, others on enquiry
  • Class of lock-up pressure zone: SZ 2.5
  • Connection
    • Pipe connections according to DIN EN ISO 8434-1 (DIN 2353), for pipe diameters 18 mm, 22 mm, 25 mm, 28 mm, 38 mm, 42 mm
    • DIN flange PN 40 or Flange Class 300, Class 600 according to ANSI 16.5 with transition pieces in DN 25, DN 40, DN 50
  • Supplemental fixture (as requested by customer):
    • Electrical and pneumatic remote setpoint adjustment

    • Fitted with noise-reducing outlet device flanges PN 40 or Class 600 according to ANSI 16.5

    • Pipe connection for use with SSVs HON 703 and/or 704.

All mechanical components of this device are without potential ignition sources and/ or hot faces. They are not subject to ATEX 95 (94/9/EC). All electronic accessories, on the other hand, meet ATEX requirements.

TECHNICAL SPECIFICATIONS

Specifications of Honeywell HON 200 Gas Pressure Regulator

PARAMETER VALUE
Model HON 200
Max. admissible pressure PS 100 bar (depending on type of flange)
Max. inlet pressure pu max up to 100 bar
Outlet pressure range Wd 0.02 bar up to 90 bar
Min. pressure drop approx. 1 bar, others on enquiry
Class of lock-up pressure zone SZ 2.5
Brand Honeywell
Standards DIN EN 334, CE per PED
Flange connections DIN PN 40 or ANSI 16.5 Class 300, 600 (DN 25, 40, 50)
Pipe connections DIN EN ISO 8434-1 (DIN 2353), 18 to 42 mm
Function Fail-close

Specifications may vary with the ordered configuration. Contact a CAD engineer for sizing to your actual operating conditions.