Detected gases: flammables; CO2; O2; H2S; CO; SO2; NH3; CL2; ClO2; NO; NO2; H2; HF; PH3; CH4; HC. Approvals: ATEX, UL, cUL, IECEx. Housing: LM25 aluminum, SS316 stainless steel

  • Supported sensor types Catalytic Bead, Electrochemical Cell, IR (point and open-path)
  • Housing material Painted LM25 aluminum; optional painted SS316 stainless steel
  • Output signals HART over 3-wire 4-20 mA (sink/source); optional Modbus RS-485, Foundation Fieldbus, 3 relays
  • 4-20 mA signal accuracy +/- 1% FS
Product description Last updated 09/2026

PRODUCT DESCRIPTION

Honeywell XNX™ Universal Gas Detector

The XNX gas detector is a complete solution designed to operate in hazardous locations, using sensor technology to detect toxic or flammable gas hazards and oxygen depletion with infrared, catalytic bead or electrochemical sensors.

Specifications:

Measured gases: O2 (0-25%), H2S (0-50ppm or 0-500ppm), CO ( 0-1000ppm), SO2 (0-20ppm or 0-50ppm), NH3 (0-200ppm or 0-1000ppm), Cl2 (0-20ppm or 0-1ppm), NO (0-100ppm), NO2 (0-50ppm), H2 (0-1000ppm or 0-10000ppm), HCL (0-20ppm), HF (0-12ppm), O3 (0-0.4ppm), PH3 (0-1.2ppm), CO2 (0-5% Vol), CH4 (0-5%Vol or 0-100% LEL), Flammable (0-100%LEL)

Supports all three sensor types: Catalytic, Electrochemical Cell and IR

Housing material: Aluminum 25, SS316 stainless steel

Output signals: 4-20mA (sink, source), HART, Modbus, Relay (option)

Accuracy: +/- 1% of full scale

Operating temperature: -40°C to +65°C

Humidity: 20% – 90%

IP: NEMA 4X IP65

Power supply: 18VDC – 32 VDC

Approvals: ATEX: Ex II 2 G D, EEx [ia] IIC T5 (Tamb -40°C to +65°C) UL: Class I, Div 1, Groups B, C, and D / Class 1, Zone 1 AEx d IIC T5 (Tamb -40°C to +65°C) CSA: Class I, Div 1, Groups B, C, and D T5 (Tamb -40°C to +65°C)

SIL Level: SIL 2

Three-color red, yellow and green display lets operators easily recognize faults from a distance

Self-test and fault diagnostics

TECHNICAL SPECIFICATIONS

Specifications of Honeywell XNX

PARAMETER VALUE
Model XNX Universal Transmitter
Supported sensor types Catalytic Bead, Electrochemical Cell, IR (point and open-path)
Housing material Painted LM25 aluminum; optional painted SS316 stainless steel
Output signals HART over 3-wire 4-20 mA (sink/source); optional Modbus RS-485, Foundation Fieldbus, 3 relays
4-20 mA signal accuracy +/- 1% FS
Operating temperature -40 °C to +65 °C (sensor dependent)
Humidity 20% - 90% RH (non-condensing)
Power supply 18 VDC - 32 VDC (24 V nominal)
SIL Level SIL 2
Brand Honeywell
Ingress protection NEMA 4X IP65