Honeywell FS24X Infrared Flame Detector
100% GENUINE
View larger
Honeywell FS24X Infrared Flame Detector

Honeywell FS24X Infrared Flame Detector

PRODUCT CODE
CAD-SF-410
BRAND
Honeywell
PRODUCT LINE
FS24X

Detects hydrocarbon and non-hydrocarbon fires. Electronic Frequency Analysis™, WideBand IR™ technology. Certifications: INMETRO, CU-TR, SIL rating, EN54-10. Materials: aluminum, stainless steel.

  • Response time 3-5 seconds for a 1 sq. ft. n-Heptane fire at 30 m; 3-10 seconds at 60 m
  • Spectral sensitivity Visible 400 – 700 nm; Near Band IR 0.7 – 1.1 µm; Wide Band IR 1.1 – 3.0 µm; Wide Band IR 3.0 – 5.0 µm
  • Operating voltage 24 Vdc nominal (18-32 Vdc), regulated
  • Operating humidity 5 to 98% relative humidity, non-condensing
Product description Last updated 09/2026

PRODUCT DESCRIPTION

Honeywell FS24X Infrared Flame Detector

FS24X is the latest generation of high-tech multi-spectrum flame detector (IR / IR / IR / Visible). Using advanced WideBand IR™ and WideBand 4.3 micron IR™ detection technology that performs in all weather conditions, the FS24X is a quantum leap in flame detection. Its algorithms, multi-function software and dual microprocessors give the FS24X the highest fire detection performance combined with optimal false alarm immunity.

Technical details:

  • Detection time: 3-5 seconds for a 1 sq. ft. n-Heptane fire at 30 m; 3-10 seconds at 60 m
  • Sensor sensitivity: 400 – 700 nanometres Near Band IR: 0.7 – 1.1 microns Wide Band IR: 1.1 – 3.0 microns Wide Band IR: 3.0 – 5.0 microns
  • Communication: selectable RS-485 ModBus or RS-485 FireBus II
  • Other optional communication: HART (excluded under EN54-10)
  • Optional software interface providing graphics, real-time data and retrieval of stored information
  • Time and date stamping of events
  • Erasable, reprogrammable flash memory
  • Power requirement: 24 Vdc
  • Operating humidity: 5 to 98% relative humidity, non-condensing
  • Operating temperature:

110° field of view FS24X: -40ºC to +85ºC (-40ºF to +185ºF);

90° field of view FS24X: -60°C to +85°C (-76°F to +185°F)

Storage: -55ºC to +110ºC (-67ºF to +230ºF)

  • Three-color visual indicator: green for power, red for alarm, yellow for fault
  • 0 – 20 mA analog output, user-selectable source
  • Alarm, Fault and Fire output relays
  • Dual microprocessors for digital sampling and signal processing, data acquisition, communication and FirePic pre-fire event data storage
  • Two ¾” NPT or 25 mm conduit entries
  • Low power consumption
  • RFI and EMI immunity
  • Approvals: FM, cFM, IECEx, ATEX, CU-TR, EN54-10, Dash 5 and SIL 2
  • Ingress protection: IP66

TECHNICAL SPECIFICATIONS

Specifications of Honeywell FS24X

PARAMETER VALUE
Model FS24X
Response time 3-5 seconds for a 1 sq. ft. n-Heptane fire at 30 m; 3-10 seconds at 60 m
Spectral sensitivity Visible 400 – 700 nm; Near Band IR 0.7 – 1.1 µm; Wide Band IR 1.1 – 3.0 µm; Wide Band IR 3.0 – 5.0 µm
Operating voltage 24 Vdc nominal (18-32 Vdc), regulated
Operating humidity 5 to 98% relative humidity, non-condensing
Operating temperature (110° field of view) -40 °C to +85 °C (-40 °F to +185 °F)
Operating temperature (90° field of view) -60 °C to +85 °C (-76 °F to +185 °F)
Storage temperature -55 °C to +110 °C (-67 °F to +230 °F)
Three-color visual indicator green for power, red for alarm, yellow for fault
Certifications FM, IECEx, ATEX, CU-TR, INMETRO, EN54-10 (FS24X-9), SIL 2 capable
Ingress protection IP66 and NEMA 4 & 4X
Brand Honeywell
Field of view FS24X-2: 110°; FS24X-9: 90°
Analog output 0 - 20 mA, source or sink selectable
Housing material Copper-free powder-coated aluminum or 316 stainless steel

Specifications may vary with the ordered configuration. Contact a CAD engineer for sizing to your actual operating conditions.