Touchpoint Pro Gas Detection Control Panel
Honeywell Touchpoint Pro is a modular gas and flame detection control system: a colour touch-screen central controller, up to 16 input modules (64 channels) and 32 output modules (128 channels), a self-healing ring network and a SIL 2 design. It accepts 4-20 mA, mV-bridge and digital inputs.
- Inputs Max 16 modules with 64 input channels
- Outputs Max 32 output modules with 128 output channels
- Input signal types 4-20 mA, mV-Bridge, digital
- Output signal types 4-20mA, Relay, Modbus RTU
- Genuine products
- Full CO/CQ
- VAT invoice
- Quote within 24 working hours
PRODUCT DESCRIPTION
Touchpoint Pro Gas Detection Control Panel
Touchpoint Pro makes it simpler to design, install, configure and operate a gas detection control system. Built on input/output modules, Touchpoint Pro adapts to projects of every size.
Touchpoint Pro is designed for applications that demand high standards such as SIL 2.
The hardware mounts in a standard electrical panel or a standard rack cabinet. Thanks to its modular flexibility, Touchpoint Pro suits everything from small projects to large, complex ones
Specifications:
- Color touchscreen interface.
- Remote input/output (Remote I/O)
- PC access via web (Web Server)
- Inputs: Max 16 modules with 64 input channels
- Outputs: Max 32 output modules with 128 output channels
- Input signal types: 4-20 mA, mV-Bridge, digital
- Output signal types: 4-20mA, Relay, Modbus RTU
- Standard enclosure: 19’’ 5U RACK UNIT
- Color touchscreen: 5.7” TFT
- Operating temperature: -20°C to +55°C
- Humidity: 10% to 90% RH (non-condensing)
- Panel door LEDs: Green, Red, Yellow.
- Panel door buttons: Alarm reset, alarm buzzer silence
- Redundancy: Allows the system to run a redundant ring loop to minimize the risk of network or hardware failure
- Connectivity: Redundant RS485 Modbus, RTU, Ethernet
- Sensors: Catalytic or IR for flammable gases, 4-20 mA type for toxic gases and oxygen, plus heat and fire detectors
- Backup battery: 24 V, 12 Ah or 27 Ah options
- Safety standards: IEC/EN 61508 and EN 50402 SIL2
Contact us today for advice tailored to your company’s requirements
System structure
According to the manufacturer, every Touchpoint Pro system is built from four blocks: a central controller with a colour touch screen, plug-in input/output modules, a backplane power and communications rail, and plug-in power supplies. They mount in cabinets or racks and can be mixed freely, so centralised, distributed (remote I/O) or mixed topologies are all possible.
- Input modules: 4-20 mA analog, mV-bridge analog (catalytic flammable sensors) and digital; output modules: relay.
- The backplane rail holds 5, 7, 9 or 10 modules depending on the power supply and enclosure version.
- 24 Vdc power supplies of 120 W, 240 W or 480 W; a redundancy module and a UPS module that charges a back-up battery.
- The ring network has two loops transmitting in opposite directions (Ring A and Ring B) and is self-healing: a failed module is detected and located without affecting the rest of the system.
Integration and interfaces
- The controller carries a Honeywell Analytics sensor catalogue for quick channel set-up; a PC can connect over Ethernet, with optional configuration software.
- Web server when networked: view status and event history, acknowledge, reset or inhibit channels; not for configuration or calibration.
- Optional redundant control centre board (CCB) that takes over if the master fails; optional Modbus RTU interface board with dual redundant RS-485.
- Compatible with most third-party flame detectors, gas detectors and manual call points.
Functional safety
The manufacturer states that Touchpoint Pro is designed to meet SIL 2 requirements (IEC/EN 61508), with its engineering process and components independently verified.
What to send for a quote
- Number of input channels by type (4-20 mA, mV-bridge, digital) and the detectors planned.
- Number of output relays and the logic to control (sounders, beacons, valve shutdown, fans).
- Mounting: wall cabinet, 19 in. rack or floor-standing cabinet; whether remote I/O is used.
- Power supply rating, UPS and battery; need for the redundant board and Modbus RTU.
CAD replies with a quote within 24 working hours of receiving the details.
TECHNICAL SPECIFICATIONS
Specifications of Honeywell Touchpoint
| PARAMETER | VALUE |
|---|---|
| Model | Touchpoint Pro |
| Inputs | Max 16 modules with 64 input channels |
| Outputs | Max 32 output modules with 128 output channels |
| Input signal types | 4-20 mA, mV-Bridge, digital |
| Output signal types | 4-20mA, Relay, Modbus RTU |
| Enclosure types | Wall-mount, 19" 5U rack (483 x 222 x 110 mm), floor-standing cabinet |
| Color touchscreen | 5.7” TFT |
| Operating temperature | -20°C to +55°C |
| Humidity | 10% to 90% RH (non-condensing) |
| Front panel LEDs | Green (power), Red (alarm), Yellow (fault), Yellow (inhibit) |
| Front panel buttons | Alarm Accept, Alarm Reset, Alarm Buzzer |
| Redundancy | Allows the system to run a redundant ring loop to minimize the risk of network or hardware failure |
| Connectivity | Redundant RS485 Modbus, RTU, Ethernet |
| Brand | Honeywell |
| Power supply | 18-32 Vdc (24 Vdc nominal) |
| Backup battery | 24 V, sealed lead-acid 12 Ah or 27 Ah |
| Safety standards | IEC/EN 61508 and EN 50402 SIL2 |
Specifications may vary with the ordered configuration. Contact a CAD engineer for sizing to your actual operating conditions.
FAQ
Frequently asked questions about CAD-SF-420
How many channels can Touchpoint Pro connect?
Up to 16 input modules (64 channels) and 32 output modules (128 channels).
Which detectors can Touchpoint Pro take signals from?
4-20 mA flammable and toxic gas detectors, mV-bridge catalytic sensors and digital signals (flame detectors, call points); it is compatible with most third-party detectors.
Does the system offer redundancy?
Yes: a self-healing ring network, an optional redundant control centre board (CCB), a power supply redundancy module and a UPS module.
Can it be viewed remotely over a network?
Yes, through the web server when networked: view status and event history, acknowledge, reset and inhibit channels. Configuration and calibration are not done over the web.
What do I need to send for a Touchpoint Pro quote?
Channel counts by signal type, number of output relays, enclosure type, power supply and UPS, and redundancy. CAD replies within 24 working hours.