Kromschröder ZMI Pilot Burner
Capacity: 1 - 4 kW. Compact size. Gas type: natural gas, LPG.
- Capacity 1 to 4 kW (ZMI 16: 1 to 2 kW; ZMI 25: 2.5 to 4 kW; ZMIC: 2.5 to 4.2 kW)
- Gas type natural gas, town gas or LPG
- Burner tube length 150 to 1000 mm
- Gas inlet pressure ZMI 15 to 70 mbar; ZMIC max. 100 mbar
PRODUCT DESCRIPTION
Kromschröder ZMI Pilot Burner
Pilot burner with a single ignition electrode, combined with an IFS / IFD or PFS / PFD automatic burner control unit
The ZMI pilot burner is suitable for many applications in the iron and steel, ceramics and non-ferrous metal industries and on heat treatment equipment. The ZMI can also be used as a stand-alone burner. Suitable for operation with natural gas, town gas or LPG.
- The pilot burner is ignited electrically and monitored by a single ignition and ionization electrode
- The ZMIC 28 with a ceramic head produces a longer, sharper flame. The ceramic tube has a long service life and suits high-temperature applications.
- Safe flame control by ionization electrode
- Reliable electrical ignition
- Slim, space-saving design thanks to single-electrode operation
- Can be used in many applications
- Capacity: 1 to 4 kW (ZMI 16: 1 to 2 kW; ZMI 25: 2.5 to 4 kW; ZMIC: 2.5 to 4.2 kW)
- Gas type: natural gas, town gas or LPG
- Burner tube length: 150 to 1000 mm
- Gas inlet pressure: ZMI 15 to 70 mbar; ZMIC max. 100 mbar
- Air inlet pressure: ZMI 15 to 90 mbar; ZMIC max. 120 mbar
TECHNICAL SPECIFICATIONS
Specifications of Kromschröder ZMI Pilot Burner
| PARAMETER | VALUE |
|---|---|
| Model | ZMI |
| Capacity | 1 to 4 kW (ZMI 16: 1 to 2 kW; ZMI 25: 2.5 to 4 kW; ZMIC: 2.5 to 4.2 kW) |
| Gas type | natural gas, town gas or LPG |
| Burner tube length | 150 to 1000 mm |
| Gas inlet pressure | ZMI 15 to 70 mbar; ZMIC max. 100 mbar |
| Air inlet pressure | ZMI 15 to 90 mbar; ZMIC max. 120 mbar |
| Ambient temperature | -15 to +60 °C |
| Max. burner tube tip temperature | ZMI < 1000 °C; ZMIC 1450 °C |
| Housing | aluminum |
| Ignition | direct spark ignition (5 kV ignition transformer) |
| Brand | Kromschröder |
| Origin | Germany |
Specifications may vary with the ordered configuration. Contact a CAD engineer for sizing to your actual operating conditions.