Kromschröder VAG Air/Gas Ratio Control with Solenoid Valve
100% GENUINE
View larger
Kromschröder VAG Air/Gas Ratio Control with Solenoid Valve

Kromschröder VAG Air/Gas Ratio Control with Solenoid Valve

PRODUCT CODE
VAG
ORIGIN
Germany
PRODUCT LINE
valVario

Kromschröder VAG is a Class A 1:1 air/gas ratio control with an integrated safety solenoid valve: outlet and air control pressure 0.5–100 mbar, max. inlet pressure 500 mbar, DN 15–65. For modulating or staged burners.

  • Brand Kromschröder (Honeywell Thermal Solutions)
  • Origin Germany
  • Type Air/gas ratio control with fixed 1:1 ratio (Class A to EN 88-1) with integrated safety solenoid valve (Class A to EN 161)
  • Outlet pressure 0.5–100 mbar
REQUEST A QUOTE DOWNLOAD DATASHEET (PDF)
  • Genuine products
  • Full CO/CQ
  • VAT invoice
  • Quote within 24 working hours

PRODUCT DESCRIPTION

Kromschröder VAG Air/Gas Ratio Control with Solenoid Valve

Kromschröder VAG is an air/gas ratio control (Class A) with an integrated safety solenoid valve; it holds the gas pressure in a fixed 1:1 ratio to an air control pressure. This page covers the VAG code only. Sibling codes in the valVario series: VAD (spring-set constant pressure governor), VAV (variable ratio 0.6:1–3:1), VAH (flow rate regulator with solenoid valve) and VRH (flow rate regulator without solenoid valve). The VAG’s own traits are the fixed 1:1 ratio and the VAG..N variant, which can be used as a zero governor for gas engines.

Specifications

  • Function: shut-off and a constant 1:1 gas/air pressure ratio for modulating burners; with the VAS 1 bypass valve also for stage-controlled burners. The pressure is preset by the air control line.
  • Outlet pressure pd: 0.5–100 mbar; air control pressure psa: 0.5–100 mbar. On excess-air burners pd and psa may be below 0.5 mbar, but no situation jeopardising safety may arise and CO formation must be avoided.
  • Gas:air ratio 1:1; zero point N adjustable at low fire ±5 mbar; turndown up to 10:1.
  • Inlet pressure always higher than the air control pressure + pressure loss + 5 mbar; max. 500 mbar (ANSI/CSA version 350 mbar). In the horizontal position with modulating control: min. inlet pressure 80 mbar.
  • Air control connection: VAG..K (1/8″ hose, 3.9 mm inside, 6.1 mm outside), VAG..E (compression fitting for 6 x 1 tube), VAG..A (1/8″ NPT), VAG..N (zero governor with breathing orifice).
  • Sizes 1–3: VAG 115, 120, 125, 240, 350 (DN 15, 20, 25, 40, 50), Rp or NPT thread, ISO 7005/ANSI flange on 240 and 350. Voltage 230, 200, 120, 100 V AC or 24 V DC.
  • Opening ≤ 1 s, closing < 1 s (VAG../N); aluminium housing, NBR seal; -20 to +60°C; IP 65.

Dimensions and weight (Rp thread version)

Size Rp thread DN Length L, threaded version (mm) Length L2, flanged version (mm) Weight (kg)
VAG 115 1/2 15 75 – 1.8
VAG 120 3/4 20 91 – 1.9
VAG 125 1 25 91 – 1.9
VAG 240 1 1/2 40 127 200 4.4
VAG 350 2 50 155 230 6.1

The NPT version (NPT thread, ANSI flange) has its own dimension table in the document (section 9.2). ISO flanges exist on sizes 240 and 350 only.

Difference from VAD, VAV, VAH, VRH

  • Versus VAD: the VAG follows the air control pressure (1:1 ratio); the VAD holds a fixed spring-set outlet pressure.
  • Versus VAV: the VAG has a fixed 1:1 ratio and one air control connection; the VAV is adjustable 0.6:1–3:1 and adds a connection for combustion chamber pressure compensation (psc).
  • Versus VAH and VRH: the VAG is driven by an air pressure, whereas VAH/VRH regulate gas flow rate in proportion to air flow rate across an orifice (3 connections). The VRH has no solenoid valve.
  • Variant only on the VAG: VAG..N is a zero governor with breathing orifice, usable for gas engines.

Applications

The valVario series is used in gas control and safety systems in the iron, steel, glass and ceramics industries, and in residential or commercial heat generation such as the packaging, paper and food industries. The VAG keeps a constant air/gas ratio on modulating burners, or on stage-controlled burners together with the VAS 1 bypass valve; the VAG..N serves as a zero governor for gas engines. The document shows an aluminium age-hardening furnace (low air pressure protection) and a melting furnace (stoichiometric combustion over the whole capacity range) as examples.

Standards / Certification

  • Class A control to EN 88-1:2011+A1:2016; Class A, Group 2 safety valve to EN 13611 and EN 161:2011+A3:2013; EN 126:2012; EN 1854:2010 (declaration of conformity for VAD/VAG/VAV/VAH/VRH sizes 1–3). UKCA: BS EN 88-1, EN 126, EN 161.
  • FM (Class 7400 and 7411), ANSI Z21.21 / CSA 6.5 (ANSI/CSA), UL 429 (120 V AC version), AGA (no. 5319); not applicable to the 100 V AC and 200 V AC versions.
  • Suitable for systems up to SIL 3 (EN 61508) / PL e (ISO 13849): single channel up to SIL 2 / PL d; SIL 3 / PL e with two redundant devices.

Compatibility / Installation

  • Keep the air control impulse line psa as short as possible, impulse tube inside diameter ≥ 3.9 mm (0.15″), so the valve reacts quickly to load changes.
  • Black solenoid actuator vertical or tilted up to horizontal, not upside down; install a filter upstream; leave 25 cm above the actuator.
  • Accessories: bypass/pilot gas valve VAS 1 (staged burners), pressure switch DG..C, test nipples, closed position switch.

What to send for a quote

To quote quickly and against the right code, please send:

  • full type code (for example VAG with size 1-3 / DN, Rp or NPT thread or ISO flange)
  • air control connection type (K hose, E compression fitting, A 1/8″ NPT or N zero governor)
  • outlet and air control pressure ranges, coil voltage (230, 200, 120, 100 V AC or 24 V DC)
  • gas type (natural gas, gaseous LPG, biogas, hydrogen or clean air), inlet pressure and required flow rate
  • quantity

CAD replies with a quote within 24 working hours.

Technical documentation (datasheet)

Kromschröder: Technical Information VAD, VAG, VAH, VAV, VRH, VCD, VCG, VCV, VCH (English, edition 08.23). This is the manufacturer’s single document for the whole series; the data for VAG is in the matching sections.

TECHNICAL SPECIFICATIONS

Specifications of Kromschröder valVario

PARAMETER VALUE
Model VAG
Brand Kromschröder (Honeywell Thermal Solutions)
Origin Germany
Type Air/gas ratio control with fixed 1:1 ratio (Class A to EN 88-1) with integrated safety solenoid valve (Class A to EN 161)
Outlet pressure 0.5–100 mbar
Air control pressure (psa) 0.5–100 mbar
Gas to air transmission ratio 1:1; adjusting range at low fire: ±5 mbar; turndown up to 10:1
Air control pressure connection VAG..K: 1 x 1/8" coupling for plastic hose (3.9 mm inside, 6.1 mm outside diameter); VAG..E: 1 x 1/8" compression fitting for 6 x 1 tube; VAG..A: 1/8" NPT adapter; VAG..N: zero governor with breathing orifice
Max. inlet pressure 500 mbar (7 psig); ANSI/CSA: 350 mbar
Min. inlet pressure higher than the air control pressure + pressure loss across the valve + 5 mbar
Sizes 1–3 (DN 15–65); Rp or NPT thread, ISO/ANSI flange on sizes 2 and 3
Power supply 230/200/120/100 V AC, +10/-15%, 50/60 Hz; 24 V DC, ±20%
Ambient temperature -20 to +60°C
Standards EN 161:2011+A3:2013; EN 88-1:2011+A1:2016; EN 126:2012; EN 1854:2010
Safety level SIL 1, 2, 3 / PL a–e depending on configuration (SIL 3 / PL e with two redundant devices)

Specifications may vary with the ordered configuration. Contact a CAD engineer for sizing to your actual operating conditions.

OTHER CODES IN THE RANGE

Same series

FAQ

Frequently asked questions about VAG

How is the VAG different from the VAD and VAV?

The VAG holds a fixed 1:1 gas/air pressure ratio to an air control pressure. The VAD regulates to a spring setting (no air control line), and the VAV has an adjustable 0.6:1–3:1 ratio with combustion chamber pressure compensation.

What are VAG..K, VAG..E, VAG..A and VAG..N?

These are air control connection kits: K is a 1/8" plastic hose coupling (3.9 mm inside, 6.1 mm outside), E a compression fitting for 6 x 1 tube, A a 1/8" NPT adapter. VAG..N is a zero governor with breathing orifice, usable for gas engines.

What pressure range does the VAG work in?

Outlet pressure and air control pressure both 0.5–100 mbar, ratio 1:1, low-fire adjustment ±5 mbar, turndown up to 10:1. Maximum inlet pressure is 500 mbar and must exceed the air pressure + pressure loss + 5 mbar.

Can the VAG be used on staged burners?

Yes. According to the manufacturer it serves modulating burners, or stage-controlled burners together with the VAS 1 bypass valve.

What do I send for a VAG quote?

The full code (for example VAG 240R/NWAE), size/DN, thread or flange, air control connection (K, E, A, N), voltage, gas type, pressures, flow rate and quantity. CAD replies with a quote within 24 working hours.

Used this product? Write a review

Your rating

20 to 1500 characters, no links.

CAD uses your name, company and text only to publish your review once approved. Your email is for CAD to check only; it is never shown or used for anything else.

Quote