Kromschröder VAD Pressure Regulator with Solenoid Valve
100% GENUINE
View larger
Kromschröder VAD Pressure Regulator with Solenoid Valve

Kromschröder VAD Pressure Regulator with Solenoid Valve

PRODUCT CODE
CAD-TH-241
ORIGIN
Germany
PRODUCT LINE
valVario

Kromschröder VAD is a Class A constant-pressure gas governor with an integrated safety solenoid valve: outlet pressure 2.5–100 mbar (-25/-50/-100 ranges), max. inlet pressure 500 mbar, DN 15–65. For industrial burner gas lines.

  • Brand Kromschröder (Honeywell Thermal Solutions)
  • Origin Germany
  • Type Constant pressure gas governor (Class A to EN 88-1) with integrated safety solenoid valve (Class A to EN 161)
  • Outlet pressure VAD..-25: 2.5–25 mbar; VAD..-50: 20–50 mbar; VAD..-100: 35–100 mbar
REQUEST A QUOTE DOWNLOAD DATASHEET (PDF)
  • Genuine products
  • Full CO/CQ
  • VAT invoice
  • Quote within 24 working hours

PRODUCT DESCRIPTION

Kromschröder VAD Pressure Regulator with Solenoid Valve

Kromschröder VAD is a Class A constant-pressure gas governor with an integrated Class A safety solenoid valve, part of Kromschröder’s (Honeywell Thermal Solutions) valVario series. This page covers the VAD code only. Sibling codes in the series: VAG (fixed 1:1 air/gas ratio control), VAV (variable air/gas ratio 0.6:1–3:1), VAH (flow rate regulator with solenoid valve) and VRH (flow rate regulator without solenoid valve). Unlike those, the VAD holds a constant outlet pressure set by the control spring, not by an air pressure.

Specifications

  • Function: shut-off and precise pressure control using servo technology; the nominal outlet pressure pd is set by the control spring.
  • Outlet pressure: VAD..-25: 2.5–25 mbar; VAD..-50: 20–50 mbar; VAD..-100: 35–100 mbar.
  • Furnace/combustion chamber pressure (-20 to +20 mbar) can be connected to the psa port to keep burner capacity constant when furnace pressure fluctuates.
  • Max. inlet pressure 500 mbar (7 psig); 350 mbar for the ANSI/CSA version.
  • Sizes 1–3: VAD 115 (DN 15), 120 (DN 20), 125 (DN 25), 240 (DN 40), 350 (DN 50). Rp thread to ISO 7-1 or NPT; ISO 7005 / ANSI flange on 240 and 350.
  • Power supply: 230, 200, 120, 100 V AC (+10/-15%, 50/60 Hz) or 24 V DC (±20%). Coil 25 W (size 1), 36–40 W (sizes 2, 3); duty cycle 100%.
  • Quick opening/closing (VAD../N): opening ≤ 1 s, closing < 1 s. The valve is closed when power is off.
  • Gases: natural gas, gaseous LPG, biogas (max. 0.1% by volume H2S), hydrogen or clean air; the gas must be clean and dry.
  • Valve seat: size 115 has the reduced valve seat (code B), the other sizes the standard seat (code A).
  • Aluminium housing, NBR seal; ambient temperature -20 to +60°C, IP 65.

Dimensions and weight (Rp thread version)

Size Rp thread DN Length L, threaded version (mm) Length L2, flanged version (mm) Weight (kg)
VAD 115 1/2 15 75 – 1.8
VAD 120 3/4 20 91 – 1.9
VAD 125 1 25 91 – 1.9
VAD 240 1 1/2 40 127 200 4.4
VAD 350 2 50 155 230 6.1

The NPT version (NPT thread, ANSI flange) has its own dimension table in the document (section 9.2). ISO flanges exist on sizes 240 and 350 only.

Difference from VAG, VAV, VAH, VRH

  • Versus VAG and VAV: the VAD regulates to a fixed set value from the control spring (three ranges -25, -50, -100), whereas VAG and VAV follow an air control pressure and therefore need an air control line (psa).
  • Versus VAH and VRH: the VAD regulates pressure; VAH/VRH regulate gas flow rate in proportion to air flow rate measured across an orifice.
  • The VAD has an integrated safety solenoid valve and closes when power is cut, like VAG, VAV and VAH; the VRH has no solenoid valve.

Applications

The valVario series is used in gas control and safety systems in the iron, steel, glass and ceramics industries, and in residential or commercial heat generation such as the packaging, paper and food industries. The VAD is used on excess-air burners, atmospheric burners and single-stage forced-draught burners; the document shows a pressure regulator on excess-air burners in the ceramics industry as an example.

Standards / Certification

  • Class A pressure regulator to EN 88-1:2011+A1:2016; Class A, Group 2 safety valve to EN 13611 and EN 161:2011+A3:2013; EN 126:2012; EN 1854:2010 (per the manufacturer’s declaration of conformity for VAD/VAG/VAV/VAH/VRH sizes 1–3).
  • UKCA: BS EN 88-1:2011, EN 126:2012, EN 161:2011+A3:2013.
  • FM (Class 7400 and 7411; NFPA 85, NFPA 86), ANSI Z21.21 / CSA 6.5 (ANSI/CSA), UL 429 (120 V AC version), AGA (no. 5319). FM, ANSI/CSA and AGA do not apply to the 100 V AC and 200 V AC versions.
  • Suitable for systems up to SIL 3 (EN 61508) and PL e (ISO 13849): single channel (HFT = 0) up to SIL 2 / PL d; SIL 3 / PL e with two redundant devices (HFT = 1) when the whole system meets the requirements.

Compatibility / Installation

  • Install a filter upstream of the system; with air as the medium also fit an activated carbon filter. Keep sealing material and thread cuttings out of the valve housing.
  • Black solenoid actuator vertical or tilted up to horizontal, not upside down. Leave at least 25 cm above the actuator and 20 mm from masonry.
  • Inlet pu and outlet pd can be measured on both sides of the body; an external impulse line can replace the pd test point for better accuracy.
  • Accessories: pressure switch DG..C, bypass/pilot gas valve VAS 1 or VBY 8 (VBY 8 for size 1), tightness control TC, test nipples, closed position switch (codes S, G).

What to send for a quote

To quote quickly and against the right code, please send:

  • full type code (for example VAD with size 1-3 / DN, Rp or NPT thread or ISO flange)
  • required outlet pressure range (-25, -50 or -100) or set pressure
  • coil voltage (230, 200, 120, 100 V AC or 24 V DC) and whether a closed position switch is needed
  • gas type (natural gas, gaseous LPG, biogas, hydrogen or clean air), inlet pressure and required flow rate
  • quantity

CAD replies with a quote within 24 working hours.

Technical documentation (datasheet)

Kromschröder: Technical Information VAD, VAG, VAH, VAV, VRH, VCD, VCG, VCV, VCH (English, edition 08.23). This is the manufacturer’s single document for the whole series; the data for VAD is in the matching sections.

TECHNICAL SPECIFICATIONS

Specifications of Kromschröder valVario

PARAMETER VALUE
Model VAD
Brand Kromschröder (Honeywell Thermal Solutions)
Origin Germany
Type Constant pressure gas governor (Class A to EN 88-1) with integrated safety solenoid valve (Class A to EN 161)
Outlet pressure VAD..-25: 2.5–25 mbar; VAD..-50: 20–50 mbar; VAD..-100: 35–100 mbar
Combustion chamber control pressure (connection psa) -20 to +20 mbar
Max. inlet pressure 500 mbar (7 psig); ANSI/CSA: 350 mbar
Sizes 1–3 (DN 15–65); Rp or NPT thread, ISO/ANSI flange on sizes 2 and 3
Power supply 230/200/120/100 V AC, +10/-15%, 50/60 Hz; 24 V DC, ±20%
Coil power 25 W (size 1); 36–40 W (sizes 2, 3)
Opening/closing time quick opening ≤ 1 s, quick closing < 1 s (VAD../N)
Ambient temperature -20 to +60°C
Enclosure IP 65
Standards EN 161:2011+A3:2013; EN 88-1:2011+A1:2016; EN 126:2012; EN 1854:2010
Safety level SIL 1, 2, 3 / PL a–e depending on configuration (SIL 3 / PL e with two redundant devices)

Specifications may vary with the ordered configuration. Contact a CAD engineer for sizing to your actual operating conditions.

OTHER CODES IN THE RANGE

Same series

FAQ

Frequently asked questions about CAD-TH-241

How is the VAD different from the VAG and VAV?

The VAD is a constant-pressure governor: its outlet pressure is set by the control spring. The VAG (1:1 ratio) and VAV (adjustable 0.6:1–3:1 ratio) control gas pressure in step with an air pressure, so they need an air control line.

What outlet pressure range does the VAD cover?

Three ranges: VAD..-25 is 2.5–25 mbar, VAD..-50 is 20–50 mbar and VAD..-100 is 35–100 mbar. Maximum inlet pressure is 500 mbar (7 psig), 350 mbar for the ANSI/CSA approval.

What sizes and connections does the VAD come in?

Sizes 1–3 (VAD 115, 120, 125, 240, 350), DN 15–65, Rp or NPT thread; ISO 7005 or ANSI flange on sizes 240 and 350. Coil voltage 230, 200, 120, 100 V AC or 24 V DC.

What burners is the VAD used on?

According to the manufacturer, on excess-air burners, atmospheric burners and single-stage forced-draught burners in gas control and safety systems.

What do I send for a VAD quote?

The full code (for example VAD 240R/NW-100A), size/DN, thread or flange type, outlet pressure range, voltage, gas type, inlet pressure, flow rate and quantity. CAD replies with a quote within 24 working hours.